510(k) Data Aggregation

    K Number
    K030592

    Validate with FDA (Live)

    Date Cleared
    2003-05-23

    (87 days)

    Product Code
    Regulation Number
    876.5860
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The capillary dialyzer/filter is intended for use in hemodiafiltration and hemofiltration for the treatments of chronic or acute renal failure.

    Device Description

    The Gambro POLYFLUX 140H, 170H and 210H Capillary Dialyzers/Filters labeled for single use have the same design, materials, intended use and function as other hemodialyzers/filters currently marketed in the United States. These devices are intended for use in hemodialysis for the treatment of acute and chronic renal failure. They may also be used in cases of acute fluid overload for the removal of plasma water. The membrane used in this device is polyarylethersulfone (PES) which is identical to the membrane utilized in the Gambro POLYFLUX 14S, 17S and 21S Hemodialyzers /filters labeled for single use which have been previously cleared for marketing in the United States under 510K Notifications (K982414). Blood enters a blood inlet port where it is distributed to the hollow fibers. Each hollow fiber has an inner diameter of approximately 200 microns (hollow fiber internal diameter) and a wall thickness of 50 microns. The number of hollow fibers in each hemodialyzer / filter is 7,500 for the POLYFLUX 140H, 9,300 for the POLYFLUX 170H, and 12,000 for the POLYFLUX 210H. This effective membrane length is 270 mm for the POLYFLUX 140H, 170H and 210H. The effective membrane surface area is 1.4 square meters for the POLYFLUX 140H, 1.7 square meters for the 170H and 2.1 square meters for the 210H. The housing and end caps of this hemodialyzer / filter are made of polycarbonate. The design and incorporation of the silicone header gasket is the same as previously approved for the Gambro GFS Plus Hemodialyzers / Filters(K902481). The fibers used in the Gambro POLYFLUX 140H, 170H and 210H are of the same composition as those previously approved for the Gambro POLYFLUX S Hemodialyzers / Filters labeled for single use (K982414). The patient's blood traverses the inside of the hollow fibers and exits the device via a blood exit port. By means of a hydrostatic pressure or transmembrane pressure which is created by a combination of positive and negative pressures across the membrane, plasma water along with certain lower and middle molecular weight solutes pass through the membrane and into the dialysate or filtrate compartment of the device. Uremic toxins and waste products are removed from the patient's blood in this device by means of both diffusion and convection through the membrane and into the countercurrent flowing dialysis solution during hemodialysis. The dialysate exits the devices via a dialysate outlet port.

    AI/ML Overview

    The provided document, a 510(k) Notification Supplement for Gambro POLYFLUX 140H, 170H & 210H Capillary Dialyzers/Filters, describes the device and its claimed substantial equivalence to predicate devices. However, the document does not contain the level of detail requested for a comprehensive acceptance criteria and study description, particularly regarding specific performance metrics, sample sizes for test and training sets, expert qualifications, or adjudication methods typically found in studies proving device performance for AI/imaging devices.

    The document focuses on demonstrating substantial equivalence to previously cleared devices (Gambro POLYFLUX 14S, 17S & 21S and Gambro GFS PLUS 20) based on similarities in design, materials, intended use, and functioning.

    Here's an attempt to answer your questions based only on the provided text, acknowledging where information is not present:


    Acceptance Criteria and Device Performance Study for Gambro POLYFLUX 140H, 170H & 210H Capillary Dialyzers/Filters

    The provided 510(k) Notification Supplement outlines the intent to market the Gambro POLYFLUX 140H, 170H, and 210H Capillary Dialyzers/Filters by demonstrating substantial equivalence to predicate devices (Gambro POLYFLUX 14S, 17S & 21S and Gambro GFS PLUS 20). The primary method used to establish this equivalence and thus "prove" the device meets acceptance criteria appears to be through comparison of design, materials, intended use, and in vitro performance testing against these predicate devices. Specific quantitative acceptance criteria or detailed study methodologies that would typically be found for an AI/imaging device are not provided in this document.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly list quantitative acceptance criteria with corresponding performance values for the new devices. Instead, the "acceptance criteria" are implicitly demonstrated through the claim of substantial equivalence to predicate devices by:

    • Identical design, materials, intended use, and function.
    • Identical membrane material (polyarylethersulfone (PES)).
    • Similar component parts.
    • Similar manufacturing processes (e.g., steam sterilization).
    • In vitro performance testing indicating performance "as well as" the predicate devices.
    Acceptance Criterion (Implicit)Reported Device Performance (Implicit)
    Safety and Effectiveness (as predicate devices)"safe, effective, and perform as well as the predicate devices"
    Design (similar to predicate devices)Same design as other hemodialyzers/filters currently marketed; specifics mentioned include hollow fiber dimensions, number of fibers, membrane length, surface area, housing materials.
    Material Composition (identical/similar to predicate devices)Main membrane (PES) identical to POLYFLUX S series; other blood and non-blood contact materials and silicone O-Ring similar/identical to predicate devices.
    Intended Use (identical to predicate devices)Polyflux H indications: hemodiafiltration and hemofiltration for chronic or acute renal failure. Identical to predicate device indications.
    Function (similar to predicate devices)"perform as well as the predicate devices" in removing uremic toxins and waste products by diffusion and convection.
    In vitro Performance (comparable to predicate devices)"In vitro performance testing was performed to establish and compare performance characteristics to the predicate devices." Data included in labeling.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided in the document. The document refers to "in vitro performance testing," but does not specify the sample size for these tests, the type of data, or its provenance (e.g., country of origin, retrospective/prospective). Given that the testing is in vitro, typical human-subject data provenance (like country of origin or retrospective/prospective) would not apply in the same way.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable/not provided. The "ground truth" for a medical device like a dialyzer would typically be established through direct physical and chemical measurements during in vitro performance testing against established standards or predicate device performance, not through expert consensus on qualitative observations.

    4. Adjudication Method for the Test Set

    This information is not applicable/not provided. As the "test set" refers to in vitro performance data, adjudication methods like 2+1 or 3+1 (common in image interpretation studies) are not relevant here. Performance is measured directly.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done or is not described. This type of study is relevant for evaluating the impact of AI systems on human reader performance, typically in diagnostic imaging. The device is a physical medical device (dialyzer), not an AI diagnostic tool.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) was Done

    This question is not applicable in the context of this device. A dialyzer is a physical device, and its performance is assessed directly through in vitro measurements, not as a standalone algorithm.

    7. The Type of Ground Truth Used

    The ground truth used for assessing the performance of the dialyzers would be based on physical and chemical measurements of their performance characteristics in vitro. This would include metrics like clearance rates for various solutes (e.g., urea, creatinine), ultrafiltration rates, and potentially biocompatibility assessments, comparing these values to established norms or the performance of the predicate devices. The document implies that "in vitro performance data are included in the labeling."

    8. The Sample Size for the Training Set

    This information is not provided and is not applicable for this type of device and submission. "Training set" is a concept used in machine learning and AI development. This document describes a traditional medical device, not an AI system.

    9. How the Ground Truth for the Training Set Was Established

    This information is not provided and is not applicable for this type of device and submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K993064

    Validate with FDA (Live)

    Date Cleared
    1999-10-06

    (23 days)

    Product Code
    Regulation Number
    876.5860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PRISMA™ System is indicated for continuous solute and/or fluid removal in patients with acute renal failure or fluid overload. All treatments administered via the PRISMA System must be prescribed by a physician.

    Device Description

    In accordance with Section 510(k) of the Food, Drug and Cosmetics Act, Gambro Renal Care Products intends to introduce a modification of the Prisma Continuous Fluid Management System into commercial distribution. The modification creates an accessory sterile extension line that will allow the Prismatherm II Blood Warmer manufactured by Stihler Electronic GmbH (K991159) to be used with the Prisma system during continuous renal replacement therapy. The integration of the Blood Warmer into the Prisma System will provide gentle warming of the treated blood, prior to its return to the patient. No modifications of the Prisma Dialysis Control Unit were made as part of this change. A modification is made to the Prisma Blood Tubing Set that places two luer fittings into the tubing set return line proximal to the air detector. When using the optional Blood Warmer, the user separates the new luer fittings and attaches the new warmer Extension Line. New labeling is created for the Extension Line and the Blood Tubing Set.

    AI/ML Overview

    This document is a 510(k) summary for a modification to the Gambro Renal Care Products' PRISMA CFM System, specifically to allow the use of an accessory blood warmer. It is not a study reporting on the performance of an AI/ML device. Therefore, the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, and ground truth cannot be extracted as it pertains to AI/ML device evaluations.

    Instead, the document focuses on demonstrating substantial equivalence to predicate devices. The "Safety and Effectiveness" section describes the approach taken to ensure the modification does not introduce new safety or effectiveness issues.

    Here's an interpretation of the relevant sections in the context of a traditional medical device submission:

    1. Table of Acceptance Criteria and Reported Device Performance:

    • Acceptance Criteria (Implied): The modification must not introduce significant new safety and effectiveness issues compared to the predicate devices. This is assessed by ensuring:
      • The design control system (21 CFR Part 820.30) is in place and addresses identified hazards.
      • System-level verification and validation protocols are completed with "acceptable, pre-determined results."
      • New hazards associated with the modification are considered in the design.
    • Reported Device Performance:
      • The modification "creates an accessory sterile extension line that will allow the Prismatherm II Blood Warmer...to be used with the Prisma system."
      • The integration "will provide gentle warming of the treated blood, prior to its return to the patient."
      • "No modifications of the Prisma Dialysis Control Unit were made as part of this change."
      • The modified system "uses similar design, technology and safety systems as the predicate devices to perform heating of the patient blood in the return line."
      • "There were no significant new safety and effectiveness issues identified by this modification."
      • A list of all system level verification and validation protocols completed with acceptable, pre-determined results is provided in the notification (though not detailed in this summary).

    Note: For a traditional device modification like this, acceptance criteria would typically involve engineering specifications, performance benchmarks (e.g., temperature control range, flow rates, sterility), and safety assessments, all aligned with the pre-determined results mentioned. This summary does not provide specific numerical criteria or performance data as it's a high-level overview for a 510(k).

    2. Sample Size Used for the Test Set and Data Provenance:

    • This information is not applicable. The document describes a device modification for which a 510(k) submission was made, not an AI/ML study involving a test set. Evaluation relies on engineering verification and validation, risk analysis, and comparison to predicate devices, rather than a "test set" in the context of an AI algorithm.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    • This information is not applicable. There is no "ground truth" establishment in the context of an AI/ML study, nor a "test set" as defined for such. Device safety and effectiveness are established through design controls, testing protocols, and regulatory review by the FDA.

    4. Adjudication Method for the Test Set:

    • This information is not applicable. There is no "adjudication method" for a test set in this context.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done:

    • No, an MRMC study was not done. This device is not an AI/ML diagnostic or assistive tool, so human reader performance with or without AI assistance is not relevant.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • No, a standalone algorithm performance study was not done. This is a hardware modification for a medical device, not an AI algorithm.

    7. The Type of Ground Truth Used:

    • This information is not applicable. There is no concept of "ground truth" (e.g., pathology, outcomes data) as it would apply to an AI/ML diagnostic model. Device safety and effectiveness are established through engineering principles, bench testing, and regulatory requirements.

    8. The Sample Size for the Training Set:

    • This information is not applicable. There is no "training set" as this is a hardware modification, not an AI/ML model.

    9. How the Ground Truth for the Training Set was Established:

    • This information is not applicable, as there is no training set or associated ground truth.