510(k) Data Aggregation

    K Number
    K213255

    Validate with FDA (Live)

    Date Cleared
    2022-06-17

    (260 days)

    Product Code
    Regulation Number
    870.2200
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K173929

    Validate with FDA (Live)

    Device Name
    CipherOx CRI M1
    Date Cleared
    2018-07-24

    (210 days)

    Product Code
    Regulation Number
    870.2200
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CipherOx™ CRI MI is indicated for continuous nonitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate (measured by an SpO2 sensor),and the Compensatory Reserve Index (CRI), which trends changes in intravascular volume relative to the individual patient's response to hypovolemia.

    For patients with a finger thickness of 0.3'' to 1'' in hospital and pre-hospital settings.

    CRI trends with changes in intravascular volume relative to the individual patient's response to hypovolemia, and should only be used by qualified medical providers as an adjunct to rather than as a replacement for traditional hemodynamic measures. CRI is indicated for adults (19-36 years old) in the supine position under non-motion conditions and without cardiovascular disease. CRI has not been studied in trauma patients.

    Device Description

    The CipherOx CRI™ M1 is a modification of the predicate device, the CipherOx CRI Tablet (DEN160020). The M1 is a smaller version of the Tablet that is designed for increased portability.

    The CipherOx CRITM M1 is a non-invasive, continuous, and multi-parameter monitor that displays SpO2, HR, and the Compensatory Reserve Index (CRI). CRITM is a physiologic parameter that trends changes in intravascular volume, which help to assess a patient's hemodynamic status.

    The CRI™ algorithm trends intravascular volume using non-invasive arterial pulsatile waveform signals by continuously comparing extracted waveforms to a reference model. CipherOx™ CRI system operates on the photoplethysmograph (PPG) waveform used in pulse oximetry to estimate CRI.

    The CipherOx CRI™ M1 incorporates:

      1. CRI™ algorithm
    • Nonin pulse ox sensor (8000AA K080255) 2.
      1. M1 User Interface module which is a small, portable, battery powered unit that displays heart rate. SpO2, and CRI™.
    AI/ML Overview

    The provided document, a 510(k) summary for the CipherOx CRI M1, focuses on demonstrating substantial equivalence to a predicate device rather than presenting a novel clinical study with new acceptance criteria for the CRI algorithm itself. The key information regarding the CRI algorithm's performance is explicitly stated to rely on the validation performed for the predicate device, the CipherOx CRI Tablet (DEN160020).

    Therefore, the acceptance criteria and study details for the CRI M1 directly reference the previous submission.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify new acceptance criteria or performance derived specifically from the CipherOx CRI M1 for the Compensatory Reserve Index (CRI). Instead, it states that the CRI algorithm is identical to that in the predicate device, the CipherOx CRI Tablet (DEN160020). The performance in terms of "Accuracy" for CRI is listed as "0-1.0 numeric with graph". For SpO2 and Pulse rate, which are standard measurements, the accuracies are provided.

    MetricAcceptance Criteria (Implied / Stated)Reported Device Performance (CipherOx CRI M1)
    Compensatory Reserve Index (CRI)Identical to DEN1600200-1.0 numeric with graph
    SpO2 Accuracy$\pm$ 2 digits (as per predicate)$\pm$ 2 digits
    Pulse Rate Accuracy18-321 BPM $\pm$ 3 digits (as per predicate)18-300 $\pm$ 3 digits

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document primarily relies on the clinical validation of the predicate device (DEN160020) for the CRI algorithm. It does not provide details of the sample size or data provenance for a test set specifically for the CRI M1's algorithm, as the algorithm itself is considered identical.

    For SpO2 accuracy, the document states: "The clinical study determining the SpO2 accuracy for the Nonin OEM III." The Nonin OEM III board is integrated into the M1. No specific sample size or provenance for this SpO2 study is given in this document, but it refers to the prior clearance of the Nonin OEM III.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided in the document. The scientific justification for the CRI algorithm's validity and clinical data requirements are stated as being fulfilled because "The CRI algorithm is identical to that in DEN160020." Therefore, this information would reside within the predicate device's 510(k) submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided in the document. As with point 3, this would be detailed in the predicate device's submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    A Multi-Reader, Multi-Case (MRMC) comparative effectiveness study is not mentioned. The device provides a Compensatory Reserve Index (CRI) as an adjunct to traditional hemodynamic measures, not a system that assists human readers in interpreting images or complex data in an MRMC study context. The focus is on the device providing a physiological parameter (CRI) for clinicians to use.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    The document implicitly confirms standalone performance for the CRI algorithm. The CRI algorithm is stated to be identical to the predicate and is responsible for calculating the CRI value based on non-invasive arterial pulsatile waveform signals. The device itself (CipherOx CRI M1) processes these signals and displays the CRI. This is an "algorithm only (without human-in-the-loop performance)" scenario for the calculation and display of CRI. However, the interpretation and use of CRI is explicitly "as an adjunct to rather than as a replacement for traditional hemodynamic measures," requiring a qualified medical provider.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The document states that the "output measure(s) must be compared to an acceptable reference method to demonstrate that the output measure(s) represent(s) the predictive measure(s) that the device provides in an accurate and reproducible manner." However, it then reiterates, "The CRI algorithm is identical to that in DEN160020." This implies the ground truth and reference methods were established during the validation of the predicate device. The specific type of ground truth (e.g., invasive hemodynamic measurements, controlled blood loss studies) is not detailed in this submission but would be in DEN160020.

    8. The sample size for the training set

    This information is not specified in the document for the CRI M1. As the CRI algorithm is entirely referenced to the predicate device (DEN160020), any training set details would be found in that submission.

    9. How the ground truth for the training set was established

    This information is not specified in the document for the CRI M1, for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN160020

    Validate with FDA (Live)

    Date Cleared
    2016-12-21

    (211 days)

    Product Code
    Regulation Number
    870.2200
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CipherOx CRI Tablet is indicated for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate (measured by an SpO2 sensor), and the Compensatory Reserve Index (CRI), which trends changes in intravascular volume relative to the individual patient's response to hypovolemia.

    For patients with a finger thickness of 0.3" to 1" in hospital and pre-hospital settings.

    CRI trends with changes in intravascular volume relative to the individual patient's response to hypovolemia, and should only be used by qualified medical providers as an adjunct to rather than as a replacement for traditional hemodynamic measures. CRI is indicated for adults (19-36 years old) in the supine position under non-motion conditions and without cardiovascular disease. CRI has not been studied in trauma patients.

    Device Description

    The CipherOx CRI Tablet consists of a Nonin Onyx II Model 9560 finger pulse oximeter (previously cleared under K081285) that communicates by Bluetooth with a Cybernet CyberMed T10 tablet PC. The CipherOx CRI Tablet is a continuous, multi-parameter monitor that displays SpO2, Heart Rate (HR), photoplethysmograph (PPG) waveform images, and the Compensatory Reserve Index (CRI) value and historical trend-line.

    CRI is an index related to the physiologic changes induced by intravascular fluid loss and ranges from 0 to 1, where 1 indicates a normal subject and 0 indicates a subject who has undergone significant physiological effects from loss of fluid volume.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the CipherOx CRI Tablet, based on the provided text:

    Acceptance Criteria and Device Performance

    The core acceptance criterion for the CipherOx CRI Tablet appears to be the accurate estimation of CRI values, specifically the root-mean-squared error (RMSE) between estimated and reference CRI.

    Acceptance CriteriaReported Device Performance
    RMSE between estimated CRI and reference CRI should be less than 0.1The verification study showed the root-mean-squared error between the estimated CRI and reference CRI according to the LBNP level to be less than 0.1.
    CRI estimates are statistically similar across multiple devicesEach of four CipherOx CRI Tablets gave statistically similar CRI estimates.
    Turning the device on/off has no significant effect on CRI estimatesTurning the CipherOx CRI Tablets on and off during the study had no significant effect on CRI estimates.
    High correlation between CRI and volume of blood removed during a blood draw studyIt was shown that there was a high correlation between CRI and volume of blood removed.
    Symptomatic subjects reaching lower CRI values during blood lossThe symptomatic group of subjects reached much lower CRI values than those who completed the blood removal without symptoms.

    Study Information

    2. Sample size used for the test set and the data provenance:

    • LBNP Verification Study: 20 healthy participants.
      • Data Provenance: The text does not explicitly state the country of origin, but the development and studies seem to be conducted by Flashback Technologies in Boulder, Colorado. The data is prospective, gathered specifically for the study.
    • Blood Draw Validation Study: 42 healthy participants (ages 19 to 36).
      • Data Provenance: Similar to the LBNP study, the country of origin is not explicitly stated but implied to be the US. The data is prospective, gathered specifically for the study.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    The text does not mention the use of experts to establish a "ground truth" in the traditional sense (e.g., diagnosis by radiologists). Instead, the ground truth for CRI was established physiologically:

    • LBNP Study: Reference CRI values were defined as CRI = 1 - LBNPcurrent / LBNPcollapse, where LBNPcollapse refers to the LBNP pressure level at the point a subject either had a precipitous fall in systolic blood pressure below 80 mmHg and/or voluntary subject termination due to discomfort or expression of presyncopal symptoms (or until completion of -100 mmHg). This relies on objective physiological measurements (blood pressure) and subjective patient reporting (presyncopal symptoms).
    • Blood Draw Study: The "ground truth" for the blood draw study was the actual volume of blood removed and the observation of symptoms (e.g., systolic blood pressure <80 mmHg or a 30% drop in mean arterial pressure) during blood loss, indicating hemodynamic decompensation.

    There is no mention of experts adjudicating these physiological ground truths.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    Not applicable. As described in point 3, the ground truth was established by physiological measurements and direct observation of patient responses to induced hypovolemia, not by expert consensus or adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    No, an MRMC comparative effectiveness study was not conducted for the CipherOx CRI Tablet. The studies focused on the performance of the device itself against physiological reference points.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Yes, the core performance testing (LBNP verification and blood draw validation) appears to be standalone algorithm performance. The device calculates CRI based on PPG data. While usability assessment involved users interpreting CRI values, the primary validation of the algorithm's accuracy in calculating CRI was performed independently.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The ground truth used was physiologically derived and based on direct physiological measurements and observed patient responses to induced hypovolemia.

    • LBNP Study: Direct measurement of LBNP levels and observation of a precipitous fall in systolic blood pressure or patient-reported presyncopal symptoms.
    • Blood Draw Study: Direct measurement of blood volume removed and observation of physiological symptoms (systolic blood pressure, mean arterial pressure drop) leading to early termination.

    8. The sample size for the training set:

    • LBNP Training Dataset: 230 healthy human volunteers.

    9. How the ground truth for the training set was established:

    The ground truth for the training set was established through the same LBNP methodology as described for the LBNP verification study:

    • LBNP Training: Reference PPG signals were collected on 230 healthy human volunteers undergoing lower body negative pressure (LBNP) to the point of presyncope. Reference CRI values were then defined as CRI = 1 - LBNPcurrent / LBNPcollapse, where LBNPcollapse refers to the LBNP pressure level at which the subject reached objective (BP drop) or subjective (presyncopal symptoms) stopping criteria. This allowed the algorithm to learn the relationship between PPG changes and known levels of induced intravascular volume changes.
    Ask a Question

    Ask a specific question about this device