    Intended Use

    The SimpleStitch Suturing System is intended for endoscopic placement of suture(s) and approximation of soft tissue (e.g., closure and healing of ESD/EMR sites, and closing of fistula, perforation or leaks).

    Device Description

    The SimpleStitch Suturing System ("SimpleStitch SS") is a sterile, single patient-use device that enables endoscopic placement of sutures and approximation of soft tissue within the gastrointestinal tract using a flexible endoscope. The system includes the following components: SimpleStitch Suture Device, SimpleStitch Suture Cartridge, and SimpleStitch Suture Cinch. The SimpleStitch SS is designed for compatibility with single-channel endoscopes (gastroscopes and colonoscopes) with a minimum working channel inner diameter of 2.8mm. During use, the suturing device/suture cartridge is mounted to the endoscope's exterior; the cinching device goes through the endoscope's working channel. The SimpleStitch SS is available with a USP 2-0 and USP 0 nonabsorbable polyester suture. Tissue is secured using a cinch anchor once tissue approximation is complete.

    AI/ML Overview

    This FDA 510(k) clearance letter and summary is for a physical medical device (SimpleStitch Suturing System), not an AI/Software as a Medical Device (SaMD). Therefore, the information typically requested for AI/SaMD performance studies (such as acceptance criteria for algorithm performance, sample size for test sets with ground truth, number of experts for ground truth, MRMC studies, standalone performance, training set details, etc.) is not applicable here.

    The document focuses on demonstrating substantial equivalence to a predicate device (OverStitch Endoscopic Suturing System) through:

    • Comparison of Technological Characteristics: Showing similarities in intended use, indications for use, principle of operation, materials, and design.
    • Performance Data: Primarily bench testing (dimensional verification, functionality, destructive testing, side-by-side comparison with predicate, usability, packaging, shelf-life), biocompatibility, MRI safety, and an animal (swine) survival study.

    There is no mention of an algorithm or AI model, nor any associated acceptance criteria, ground truth establishment, or statistical performance metrics typically associated with AI/SaMD.

    Therefore, I cannot provide the requested information regarding acceptance criteria and study proof in the context of an AI/SaMD for this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242923

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-12-20

    (87 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SimpleSnip Suture Cutter is intended to cut sutures during all flexible endoscopic procedures.

    Device Description

    The SimpleSnip Endoscopic Suture Cutter is sterile, single patient-use device intended to cut sutures during flexible endoscopic procedures. The cutting device goes through the working channel of the endoscope and is compatible with flexible endoscopes with a minimum channel diameter of 2.8mm. The device is available in two working lengths: 160cm working length for gastroscopes and 230 cm working length for colonoscopes. The device consists principally of a proximal handle assembly, a catheter with core wire, and a blade to cut the suture. Once the SimpleSnip device is inserted in the working channel of the endoscope, the blade is advanced from the catheter, the suture is captured within the blade such that when the blade is pulled back toward the catheter the suture is cut. The blade is rotatable to allow easy suture capturing and cutting.

    AI/ML Overview

    I am sorry, but the provided text does not contain information about acceptance criteria and a study proving a device meets these criteria. The document is an FDA 510(k) clearance letter for the SimpleSnip Endoscopic Suture Cutter, detailing its substantial equivalence to a predicate device. It includes information about the device description, indications for use, comparison with a predicate device, and performance/biocompatibility/sterilization testing conducted.

    Specifically, it states:

    • "No clinical studies were deemed necessary to demonstrate the safety and effectiveness of the subject device." This means there isn't a clinical study with acceptance criteria and reported performance in the context of human data.
    • The performance data mentioned is primarily bench testing and functional testing, as well as comparative testing against the predicate device for certain mechanical aspects (rotation, actuation, bending stiffness). These tests are designed to verify specifications and show equivalence, not necessarily to meet pre-defined clinical performance acceptance criteria against human outcomes.

    Therefore, I cannot fulfill your request for:

    1. A table of acceptance criteria and reported device performance.
    2. Sample size used for a test set or data provenance for a clinical study.
    3. Number of experts or their qualifications for ground truth establishment.
    4. Adjudication method.
    5. MRMC comparative effectiveness study details.
    6. Standalone algorithm performance.
    7. Type of ground truth for a clinical study.
    8. Sample size for a training set.
    9. How ground truth for the training set was established.

    This document focuses on demonstrating substantial equivalence through non-clinical data and comparison to a predicate device, which is common for 510(k) submissions where clinical studies are not deemed necessary.