510(k) Data Aggregation

    K Number
    K994098

    Validate with FDA (Live)

    Date Cleared
    2000-05-23

    (172 days)

    Product Code
    Regulation Number
    880.6250
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A medical gloves is worn on the hand of health care and similar personnel to prevent contamination between health care personnel and the patient's body, fluids, waste, or environment.

    A patient examination glove is a disposable device intended for medical purpose worn on the examiner's hand or finger to prevent contamination between patient and examiner.

    Device Description

    Glove, Disposable, Non-sterile, Patient Examination, Vinyl (Powder Free)

    AI/ML Overview

    The provided text describes the acceptance criteria and performance of the EVERGREEN MEDICAL PRODUCTS Vinyl Patient Examination Gloves - Powder Free. However, it does not contain information about a study proving the device meets the acceptance criteria in the manner of a multi-reader, multi-case (MRMC) comparative effectiveness study, or a standalone (algorithm only) performance study as typically seen for AI/ML medical devices. The document is a 510(k) summary for a medical device (examination gloves), which follows a different set of regulatory requirements focused on demonstrating substantial equivalence to a predicate device.

    Instead, the "study" described in this document is essentially a series of quality characteristic tests performed against established ASTM and FDA standards for patient examination gloves.

    Here's the breakdown of the information requested, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    CharacteristicAcceptance Criteria (Specification)Reported Device Performance (Implied from meeting specifications)
    Physical Dimensions
    Circumference of Palm (mm)Small: 178; Medium: 210; Large: 218; Ex-Large: 230Met (implied by statement "meet ASTM D5250-99 performance standard")
    Total Length (+/- 5 mm)Small: 240; Medium: 245; Large: 245; Ex-Large: 245Met (implied by statement "meet ASTM D5250-99 performance standard")
    Length of Fingers (mm)Thumb: 55-63; Index: 66-78; Middle: 74-92; Ring: 69-82; Little: 54-62Met (implied by statement "meet ASTM D5250-99 performance standard")
    Circumference of Fingers (mm)Thumb: 63-83; Index: 56-74; Middle: 59-76; Ring: 56-73; Little: 50-66Met (implied by statement "meet ASTM D5250-99 performance standard")
    Mechanical Properties
    Tensile Strength (Mpa)Min. 10.0Met Min. 10.0 (implied by statement "meet ASTM D5250-99 performance standard")
    Elongation350%Met 350% (implied by statement "meet ASTM D5250-99 performance standard")
    Weight7.0 (Small), 8.0 (Medium), 9.0 (Large), 9.5 (Ex-Large) +/- 0.2gMet (implied by statement "meet ASTM D5250-99 performance standard")
    ThicknessFinger Tip: 0.08 mm +/- 0.02 mm; Cuff: 0.09 mm +/- 0.02 mm; Palm: 0.15 mm +/- 0.02 mmMet (implied by statement "meet ASTM D5250-99 performance standard")
    Quality AssuranceUnder 2.5% Pinhole Rate (FDA Glove 1000ml Water Leak Test)Met (stated under Quality Assurance table entry) and explicitly stated in the conclusion: "meet pinhole requirements"
    BiocompatibilityPrimary Dermal Irritation in Rabbits (Pass); Guinea Pig Sensitization (Buehler) (Pass)Met (implied by testing issued by Consumer Products Testing Co.)
    Powder ResiduePowder Free, Weight of all types of residual powder on medium size glove is 0 milligram per glove (implicit standard for "Powder Free" claims)0 milligram per glove (explicitly stated: "Weight of all types of residual powder on medium size glove is 0 milligram per glove. The gloves are powder free and the process does not include any powder.")
    Overall Performance StandardASTM Specification D 5250-99Met (explicitly stated in the conclusion: "The vinyl Patient Examination gloves (powder free)... meet ASTM D5250-99 performance standard")

    2. Sample size used for the test set and the data provenance:

    • The document does not specify a distinct "test set" sample size in terms of number of gloves tested for each characteristic. It refers to established standards and tests (e.g., JIS-S-2045.509, JIS-S-2045.5.2, FDA Glove 1000ml Water Leak Test, Primary Dermal Irritation in Rabbits, Guinea Pig Sensitization). These standards imply specific sampling plans.
    • Data Provenance: The tests for biocompatibility were "Issued by Consumer Products Testing Co." The document states the manufacturer is located in Shijiazhuang City, Hebei, China. Thus, the provenance of the testing data is likely China. The study is retrospective in the sense that the data presented reflects the results of quality control and testing performed on manufactured batches to demonstrate compliance with standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This concept is not applicable here as this is a physical medical device (gloves) and not an AI/ML diagnostic or image analysis device that requires expert consensus for "ground truth." The "ground truth" for the performance characteristics are the established ASTM and FDA standards themselves. The assessment is against these objective measurements.

    4. Adjudication method for the test set:

    • This concept is not applicable. Performance against physical and chemical specifications does not involve "adjudication" by experts in the context of diagnostic interpretation. The methods are standardized physical and chemical tests (e.g., measuring length, tensile strength, pinhole rate via water leak test, biological irritation tests).

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC comparative effectiveness study was not done. This type of study is relevant for AI/ML diagnostic systems, not for examination gloves.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    • No, a standalone (algorithm only) performance study was not done. This type of study is relevant for AI/ML diagnostic systems, not for examination gloves.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • The "ground truth" for this device's performance is adherence to established, objective material and physical specifications and testing standards (e.g., ASTM Specification D 5250-99 for physical properties, FDA Glove 1000ml Water Leak Test for pinholes, and standard biocompatibility tests).

    8. The sample size for the training set:

    • This concept is not applicable. This device is not an AI/ML algorithm that requires a "training set." The manufacturing process itself (described in Section 10.0) is continuously refined and controlled, but there isn't a "training set" in the sense of data used to train a model.

    9. How the ground truth for the training set was established:

    • This concept is not applicable, as there is no "training set." The standards for glove manufacturing and performance are established by regulatory bodies and industrial organizations (e.g., ASTM, FDA) based on extensive research and consensus within the medical and materials science communities to ensure safety and effectiveness for their intended use.
    Ask a Question

    Ask a specific question about this device

    K Number
    K994099

    Validate with FDA (Live)

    Date Cleared
    2000-04-12

    (131 days)

    Product Code
    Regulation Number
    880.6250
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A medical gloves is worn on the hand of health care and similar personnel to prevent contamination between health care personnel and the patient's body, fluids, waste, or environment.
    A patient examination glove is a disposable device intended for medical purpose worn on the examiner's hand or finger to prevent contamination between patient and examiner.

    Device Description

    Glove, Disposable, Non-sterile, Patient Examination, Vinyl (Pre-powdered)

    AI/ML Overview

    The provided text describes the specifications and quality control scheme for vinyl patient examination gloves, rather than a medical device with an algorithm or AI component requiring a study to prove acceptance criteria in the typical sense of AI/ML devices. Therefore, many of the requested categories in the prompt (e.g., sample size for test set, number of experts for ground truth, adjudication method, MRMC study, standalone performance, training set sample size, ground truth for training set) are not applicable to this document.

    However, I can extract the acceptance criteria and the methods used to show the device meets those criteria based on the provided information, which primarily references ASTM and ISO standards for physical characteristics and manufacturing quality.

    Here's a summary tailored to the provided document:

    Acceptance Criteria and Device Performance for Vinyl Patient Examination Gloves

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document outlines acceptance criteria based on two main sections:

    • "SPECIFICATION OF VINYL GLOVES (Ambidextrous)" (Page 2) which lists specific physical dimensions and performance requirements. This section appears to be the target specification for the gloves.
    • "PERFORMANCE REQUIREMENTS FOR QUALITY CHARACTERISTICS" AND "QUALITY CHARACTERISTICS" (Pages 5-6) which detail the quality control parameters and their associated Assurance Actions and AQLs (Acceptable Quality Levels). This section describes how the product is monitored and accepted during manufacturing.

    Table 1: Acceptance Criteria and Reported Device Performance (Summary from Specifications and Quality Control)

    CharacteristicAcceptance Criteria (Specification) & Assurance ActionReported Device Performance (Implied by meeting standards)
    Physical Dimensions
    Circumference of PalmSmall: 178mm (6-3/4")Medium: 210mm (7-3/4")Large: 218mm (8-1/2")Ex-Large: 230mm (9")Meets JIS-S-2045.509
    Total Length240-245mm (+/- 5 mm)Meets JIS-S-2045.5.9
    Length of FingersVaries by finger & size (e.g., Small Thumb: 55mm, Middle Finger: 74mm)Meets JIS-S-2045.5.9
    Circumference of FingersVaries by finger & size (e.g., Small Thumb: 63mm, Middle Finger: 59mm)Meets JIS-S-2045.5.9
    Overall Length (QC)240 +/- 10 mm (Test method A1, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Width (QC)Small: 83 +/- 5 mmMedium: 94 +/- 5 mmLarge: 105 +/- 5 mmEx-Large: 114 +/- 5 mmMeets specification (Implied)
    Thickness
    Finger Tip0.08 mm +/- 0.02 mm(Not explicitly shown whether met from spec table)
    Cuff0.09 mm +/- 0.02 mm(Not explicitly shown whether met from spec table)
    Palm0.15 mm +/- 0.02 mm(Not explicitly shown whether met from spec table)
    Thickness (QC, double wall)Finger: 0.48 mm Max.Cuff: 0.20 mm Min. (Dimensional control, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Mechanical Properties
    Tensile Strength (Before Aging)Min. 10.0 MpaMeets JIS-S-2045.5.2
    Elongation (Before Aging)Min. 350%Meets JIS-S-2045.5.2
    Tensile Strength (After Aging)Min. 10 Mpa (Test method A4, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Elongation (After Aging)Min. 350% (Test method A4, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Other Properties
    Weight7.0-9.5 g/pc (+/- 0.2g)(Implied to meet specification)
    Pinhole RateUnder 2.5% Pinhole Rate (FDA Glove 1000ml Water Leak Test)Meets specification (Implied)
    Inside pH (QC)7 +/- 1 (Test method A2, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Powder level (QC)Inside: max. 2.5 +/- 1.0 by weightOutside: max. 1.0% by weight (Test method A3, Inspection level S-2, AQL 2.5)Meets specification (Implied)
    Pinhole & Visual Defects (QC)AQL 1.0 for Category 1 defects (Holes, cuts, tears)AQL 2.5 for Category 2 defects (Pleats, Lumps, Dirty/foreign spot, Embedded particles, Thin spots, Discoloration, Torn bead)Meets specification (Implied)
    Final Glove ReleaseAQL 1.5 for leaksAQL 4.0 for leaks and visual defects aggregated (Inspection level 1, normal inspection, multiple sampling)Meets US FDA Test Method for Leakage Defects

    The conclusion states: "The vinyl Patient Examination gloves (Pre-powdered) manufactured by Evergreen Medical products (Jingxing) Co., Ltd. meet ASTM D5250-99 Standard and meet pinhole requirements and labeling claims." This is the direct statement of performance against the acceptance criteria.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: The document refers to sampling procedures in accordance with ISO 2859 ("Sampling procedures and Tables for Inspection by Attributes"). It also mentions "median of not less than three measurements" for thickness (A.1), "median of at least 10 results" for residual powder (A.3), and "median of not less than 5 test results" for physical requirements (A.4). However, specific numerical sample sizes for the overall test set (e.g., number of gloves tested for full compliance) are not explicitly stated. The AQL (Acceptable Quality Level) values (e.g., 2.5, 1.0, 1.5, 4.0) and Inspection Levels (e.g., S-2, II, 1) refer to the statistical sampling plans within ISO 2859 and US FDA Test Methods, which would dictate the sample sizes based on lot size, but these specific numbers are not provided.
    • Data Provenance: Not applicable in the context of an "AI device." The testing would be performed on manufactured batches of physical gloves at the manufacturing site (Evergreen Medical Products (Jingxing) Co., Ltd.) in China, as part of their quality control process. The biocompatibility testing was "Issued by Consumer Products Testing Co."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as this is a physical product (gloves) and not an AI/ML device relying on expert-labeled data. Ground truth here refers to adherence to objective physical and chemical standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable for the reasons stated above. Testing involves measuring characteristics against predefined physical/chemical limits. Visual inspection for defects ("Visual, Sensual" in Section 22.0) would follow established quality control protocols, but not multi-expert adjudication in the AI sense.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is not an AI device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an AI device.

    7. The type of ground truth used:

    • The "ground truth" for the device's performance is adherence to established international and national standards for medical gloves:
      • ASTM Specification D 5250-99 (Standard Specification for Vinyl Examination Gloves for Medical Application) for general glove properties.
      • JIS-S-2045.509/5.9/5.2 for specific dimensions and mechanical tests.
      • ISO 2859 for sampling procedures.
      • US FDA Test Method for Leakage Defects as published in the Federal Registration of Nov. 31, 1989 (21 CFR Part 800.20) for pinholes.
      • ASTM D 3578 (Standard Specification for Rubber Examination Gloves) for physical requirements (aging).
      • BS 4005 (Single Use Sterile Surgical Rubber Gloves, Appendix C) for air inflation and cuff test (partial adherence).
      • Biocompatibility testing results (Primary Dermal Irritation in Rabbits, Guinea Pig Sensitization) for safety.
      • Chemical composition (Polyvinyl Chloride, Plasticizers, etc.) against specified percentages.
      • Manufacturing Practice: Compliance with current Good Manufacturing Practice (GMP) requirements.

    8. The sample size for the training set:

    • Not applicable. This is not an AI device.

    9. How the ground truth for the training set was established:

    • Not applicable. This is not an AI device.