Found 4 results

510(k) Data Aggregation

    K Number
    K232722

    Validate with FDA (Live)

    Date Cleared
    2023-10-03

    (28 days)

    Product Code
    Regulation Number
    862.1358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    endo.digital Platform is intended for the management of diabetes by people with diabetes and their healthcare providers in order to report, upload, log, track, share, monitor and review their data using web and mobile applications. endo.digital Platform also enables communication between people with diabetes and their healthcare providers as well as among healthcare providers.

    endo.digital Platform enables the healthcare provider to use endo.digital Algorithm for treatment recommendations as described below and prescribe endo.digital Bolus Calculator for patient use.

    endo.digital Algorithm is a decision-support software intended for assisting healthcare professionals in the management of their patients with diabetes who monitor their glucose levels using continuous glucose monitor (CGM) and/or Self-Monitoring Blood Glucose (SMBG) meter; and use any of the following insulin types as their therapy to manage glucose levels via subcutaneous injections or continuous sub-cutaneous insulin infusion (CSII; insulin pump) reported either manually or automatically:

    • Long acting insulins (for injections only)
    • Short acting insulins:
      • Rapid acting analogs (for injections and insulin pump according to manufacturer indications for use)
      • Regular human insulin (for injections only)

    endo.digital Algorithm is intended to be used for patients with:

    • Type 1 diabetes over the age of 6 using an insulin pump or subcutaneous insulin injections.
    • Type 2 diabetes over the age of 10 who use subcutaneous insulin injections.

    endo.digital Algorithm is indicated for use by healthcare professionals when analyzing CGM, SMBG and/or insulin delivery data to generate recommendations for optimizing a patient's insulin treatment plan for basal therapy and/or bolus therapy and/or glucose targets, without considering the full clinical status of a particular patient. endo.digital Algorithm does not replace clinical judgement.

    endo.digital Bolus Calculator, a component of the DreaMed Diary App, is a diabetes management tool for people with type 1 diabetes above the age of 6 and type 2 diabetes above the age of 10, who use subcutaneous insulin injections therapy (not for pump use). This tool can help calculate their rapid acting analogs for insulin bolus doses based on user-entered blood glucose and/or meal information.

    The initial setup of the user's treatment plans, and bolus calculator settings must be performed by a healthcare provider.

    Device Description

    endo.digital Platform is a software device that is designed to be a diabetes management platform. It includes endo.digital Algorithm that provides insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 1 diabetes using an insulin pump or multiple daily injections, a continuous glucose monitoring (CGM) system and/or self-management blood glucose meter (SMBG). endo.digital Algorithm also provides insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 2 diabetes on basal-bolus therapy via multiple daily injections (MDI), a continuous glucose monitoring (CGM) system and/or self-management blood glucose meter (SMBG). endo.digital Algorithm gathers and analyzes information inputted through the Diabetes Management Systems (DMS), which collect biological input information from various diabetes devices and data sources including the DreaMed Diary App. Diabetes device information required and used by endo.digital Algorithm includes glucose readings (either CGM sensor readings and/or capillary blood glucose measurements), insulin dosing logs, and meal data during daily routine care. Following data collection and analysis, the endo.digital Algorithm generates results containing summary data and recommendations for adjustments to the patient's insulin therapy parameters, including basal insulin delivery rate(s), insulin to carbohydrate ratio and correction factor (insulin sensitivity) for pump patients, and for MDI patients a daily injection plan including a basal plan and either a sliding scale (which can include Fixed Meal and Meal Estimation plans) or insulin to carbohydrate ratio and correction factor (insulin sensitivity) for bolus injections. endo.digital Algorithm may also advise on personalized diabetes management tips. Results are sent to the Diabetes Management System, which displays results to physicians and a report provided by the algorithm. The physician can approve, reject or change the recommendations and issue the updated treatment plan to the patient. For MDI patients using rapid acting analogs for insulin bolus dose, the healthcare provider may prescribe endo.digital Bolus Calculator which is integrated in the DreaMed Diary App to aid in calculating their bolus injections.

    AI/ML Overview

    The provided text details the 510(k) premarket notification for the "endo.digital Platform." While it discusses the device's intended use, description, and substantial equivalence to a predicate device, it does not contain specific information about the acceptance criteria or the study that proves the device meets those criteria. The document states that "software performance data demonstrates that endo.digital Platform is as safe and effective as the predicate device" and that "Design validation testing results confirmed that endo.digital Platform performs according to the stated intended use. Software evaluation consisted of functional testing performed pursuant to DreaMed's software test plan. All test results fell within the pre-determined specification parameters and acceptance criteria." However, it does not provide the acceptance criteria themselves, nor the details of the studies conducted to meet them.

    Therefore, I cannot fulfill your request for:

    1. A table of acceptance criteria and the reported device performance: This information is not present in the document.
    2. Sample size used for the test set and the data provenance: This information is not provided.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not provided.
    4. Adjudication method for the test set: Not provided.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and its effect size: Not mentioned. The device is a "decision-support software intended for assisting healthcare professionals," implying a human-in-the-loop, but no MRMC study details are shared.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not specified.
    7. The type of ground truth used: Not specified.
    8. The sample size for the training set: Not provided.
    9. How the ground truth for the training set was established: Not provided.

    The document focuses on the regulatory submission, equivalence to a predicate device ("Advisor Pro Platform, K210561"), and the general statement that "software performance data demonstrates that endo.digital Platform is as safe and effective as the predicate device." It also mentions "functional testing performed pursuant to DreaMed's software test plan" and that "All test results fell within the pre-determined specification parameters and acceptance criteria," but it does not disclose the specifics of these tests or criteria.

    To obtain the requested information, one would typically need to review the full 510(k) submission, which often includes detailed validation reports, clinical studies, and software verification and validation documentation. These are usually not fully disclosed in the public 510(k) summary letter.

    Ask a Question

    Ask a specific question about this device

    K Number
    K210561

    Validate with FDA (Live)

    Date Cleared
    2021-09-28

    (215 days)

    Product Code
    Regulation Number
    862.1358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Advisor Pro Platform is intended for the management of diabetes by people with diabetes and their health care providers in order to report, log, track, share, monitor and review their data using the dedicated computer or mobile software. Advisor Pro Platform also enables communication between people with diabetes and their health care providers as well as among health care providers.

    The Advisor Pro Platform enables the healthcare provider to use the Advisor Pro Algorithms for treatment recommendations as described below and prescribe the Advisor Pro Bolus Calculator for patient use.

    Advisor Pro Algorithm is a decision-support software intended for assisting healthcare professionals in the management of their patients with diabetes who monitor their glucose levels using continuous glucose monitor (CGM) and/or Self-Monitoring Blood Glucose (SMBG) meter; and use any of the following insulin types as their therapy to manage glucose levels via subcutaneous injections or continuous sub-cutaneous insulin infusion (CSII; insulin pump) reported either manually or automatically:

    • Long Acting insulins (for injections only)
    • Short acting insulins:
      • Rapid acting analogs (for injections and insulin pump according to manufacturer indications for use)
      • Regular human insulin (for injections only)

    The Advisor Pro algorithm is intended to be used for patients with:

    • Type 1 diabetes over the age of 6 using an insulin pump or subcutaneous insulin injections.
    • Type 2 diabetes over the age of 10 who use subcutaneous insulin injections.

    Advisor Pro Algorithm is indicated for use by healthcare professionals when analyzing CGM, SMBG and/or insulin delivery data to generate recommendations for optimizing a patient's insulin treatment plan for basal therapy and/or bolus therapy and/or glucose targets; without considering the full clinical status of a particular patient. Advisor Pro Algorithm does not replace clinical judgment.

    The Advisor Pro Bolus Calculator, a component of the DreaMed Diary App, is a diabetes management tool for people with type 1 diabetes above the age of 6 and type 2 diabetes above the age of 10, who use subcutaneous insulin injections therapy (not for pump use). This tool can help calculate their rapid acting analogs for insulin bolus doses based on user-entered blood glucose and/or meal information.

    The initial setup of the user's treatment plans, and bolus calculator settings must be performed by a healthcare provider.

    Device Description

    The Advisor Pro Platform is a software device that is designed to be a diabetes management platform. It includes the Advisor Pro Algorithm that provides insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 1 diabetes using an insulin pump or multiple daily injections, a continuous glucose monitoring (CGM) system and/or self-management blood glucose meter (SMBG). The Advisor Pro Algorithm also provides insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 2 diabetes on basal-bolus therapy via multiple daily injections (MDI), a continuous glucose monitoring (CGM) system and/or self-management blood glucose meter (SMBG).

    The Advisor Pro Algorithm gathers and analyzes information inputted through the Diabetes Management Systems (DMS), which collects biological input information from various diabetes devices and data sources including the DreaMed Diary App. Diabetes device information required and used by Advisor Pro Algorithm includes glucose readings (either CGM sensor readings and/or capillary blood glucose measurements), insulin dosing logs, and meal data during daily routine care.

    Following data collection and analysis, the Advisor Pro Algorithm generates results containing summary data and recommendations for adjustments to the patient's insulin therapy parameters, including basal insulin delivery rate(s), insulin to carbohydrate ratio and correction factor (insulin sensitivity) for pump patients and for MDI patients a daily injection plan including a basal plan and either a sliding scale or insulin to carbohydrate ratio and correction factor (insulin sensitivity) for bolus injections. Advisor Pro Algorithm may also advise on personalized diabetes management tips. Results are sent to the Diabetes Management System, which displays results to physicians and a report provided by the algorithm. The physician can approve, reject or change the recommendations and issue the updated treatment plan to the patient.

    For MDI patients using rapid acting analogs for insulin bolus dose, the healthcare provider may prescribe the Advisor Pro Bolus Calculator which is integrated in the DreaMed Diary App to aid in calculating their bolus injections.

    AI/ML Overview

    The provided text describes the DreaMed Advisor Pro Platform, a software device intended for diabetes management. It includes two main components: the Advisor Pro Algorithm (a decision-support tool for healthcare professionals) and the Advisor Pro Bolus Calculator (for patient use).

    Here's an analysis of the acceptance criteria and the study proving device performance based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of quantitative acceptance criteria with corresponding performance metrics like sensitivity, specificity, accuracy, or specific thresholds for agreement. Instead, it focuses on demonstrating that the device's recommendations are "as good as" or "similar to" those of experts.

    Acceptance Criteria (Implied)Reported Device Performance
    Device performs according to stated intended use ("functional testing")"All test results fell within the pre-determined specification parameters and acceptance criteria."
    User interface adequately validated for use"The human factors, design, and labeling information provided in the submission confirm that the user interface has been adequately validated for use per the labeling." (Human factors testing was conducted with intended user populations of patients and healthcare providers)
    Algorithm recommendations agree with expert recommendations"The study results show that the recommendations of the Advisor Pro Algorithm Pro for MDI patients Type 1 and Type 2 were significantly as good as the recommendations of expert in the basal and bolus plan with regards to the overall level of agreement in the direction of change. Therefore, the Advisor Pro Algorithm recommendations could be considered similar to those given by healthcare professional who work at leading centers with a wealth of experience in the field of diabetes and who are especially familiar with diabetes technology devices."
    No new safety or effectiveness concerns"DreaMed Diabetes believes that the changes as described in this 510(k) submission do not present additional safety or effectiveness concerns for the Advisor Pro Platform including the Advisor Pro Algorithm as well as the Advisor Pro Bolus Calculator and is substantially equivalent to the predicates cited."

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: The clinical study involved a data set of 17 Type 1 patients and 15 Type 2 patients.
    • Data Provenance: The document does not specify the country of origin for the data. It indicates the study was "retrospective clinical study."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Number of Experts: A total of 36 experts were involved.
    • Qualifications of Experts: The text states these were "healthcare professional who work at leading centers with a wealth of experience in the field of diabetes and who are especially familiar with diabetes technology devices." Specific professional titles (e.g., endocrinologist, specialized diabetes nurse), years of experience, or board certifications are not provided.

    4. Adjudication Method for the Test Set

    The document states, "Recommendations were compared to examine the level of agreement between one expert to his colleague versus the level of agreement between Advisor Pro Algorithm recommendations and experts." This implies some form of comparison or consensus evaluation, but a specific adjudication method (e.g., 2+1, 3+1) is not explicitly detailed. It seems to be a comparison of agreement levels rather than a formal adjudication process to establish a single ground truth from multiple expert reads for each case.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    While the study involved multiple experts evaluating cases and comparing their recommendations to the algorithm and to each other, the description doesn't explicitly label it as a formal MRMC comparative effectiveness study in the sense of directly measuring human reader improvement with AI assistance vs. without.

    The study aimed to show that the AI's recommendations were "as good as" expert recommendations. It compared "the level of agreement between one expert to his colleague versus the level of agreement between Advisor Pro Algorithm recommendations and experts."

    Therefore, it was not a direct MRMC study to quantify how much human readers improve with AI assistance. It was designed to show the equivalence/similarity of the algorithm's recommendations to those of experts. No effect size for human reader improvement with AI assistance is reported because that was not the stated purpose of this particular comparison.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, the study described is a standalone performance evaluation of the Advisor Pro Algorithm's recommendations compared to expert recommendations. The algorithm generated recommendations independently, which were then compared to expert decisions.

    7. The Type of Ground Truth Used

    The ground truth for the clinical study appears to be expert consensus or expert recommendations for insulin therapy adjustments. The algorithm's recommendations were compared against the recommendations of these experts to establish "level of agreement."

    8. The Sample Size for the Training Set

    The document does not provide information regarding the sample size used for the training set for the Advisor Pro Algorithm. The clinical study described involved a test set.

    9. How the Ground Truth for the Training Set Was Established

    The document does not provide information on how the ground truth for the training set was established. The clinical study described focuses on the evaluation of the algorithm's performance on a test set, not on its training data.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201476

    Validate with FDA (Live)

    Date Cleared
    2020-08-28

    (86 days)

    Product Code
    Regulation Number
    862.1358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DreaMed Advisor Pro is a decision-support software intended for assisting healthcare professionals in the management of patients with Type 1 diabetes who:

    · use insulin pumps as their insulin delivery therapy;

    · monitor their glucose levels using continuous glucose monitoring (CGM) and/or Self-Monitoring Blood Glucose (SMBG) meter;

    • are above the age of 6; and

    · use rapid acting U-100 insulin analogs in their pump

    DreaMed Advisor Pro is indicated for use by healthcare professionals when analyzing CGM, SMBG and pump data to generate recommendations for optimizing a patient's insulin pump settings for basal rate, Carbohydrate Ratio (CR), and Correction Factor (CF); without considering the full clinical status of a particular patient. DreaMed Advisor Pro does not replace clinical judgement.

    Device Description

    DreaMed Advisor Pro is a software device that is designed to provide insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 1 diabetes using an insulin pump, a continuous glucose monitoring (CGM) system and self-management blood glucose meter (SMBG).

    The DreaMed Advisor Pro gathers and analyzes information inputted through qualified Diabetes Management Systems (DMS), which collects biological input information from various diabetes devices. Diabetes device information required and used by DreaMed Advisor Pro includes glucose readings (either CGM sensor readings and/or capillary blood glucose measurements), insulin dosing logs, and meal data during daily routine care.

    Following data collection and analysis, the DreaMed Advisor Pro generates results containing summary data and recommendations for adjustments to the patient's insulin therapy parameters, including basal insulin delivery rate(s), insulin to carbohydrate ratio and correction factor (insulin sensitivity). DreaMed Advisor Pro may also advise behavioral changes. Results are sent to a qualified Diabetes Management Systems, which displays results to physicians and a report provided by DreaMed Diabetes. The physician can approve, reject or change the recommendations and issue the updated treatment plan to the patient.

    AI/ML Overview

    The provided text is a 510(k) summary for the DreaMed Advisor Pro, which is a software device intended to assist healthcare professionals in managing Type 1 diabetes. It primarily describes the device, its intended use, and argues for its substantial equivalence to a previously cleared version of the same device (K191370).

    However, the document does not contain the detailed information requested about acceptance criteria, specific study results, sample sizes for test and training sets, expert qualifications, adjudication methods, or MRMC comparative effectiveness studies. It simply asserts that the updated DreaMed Advisor Pro is "as safe and effective" as the previously cleared one, with the only change being an expansion of the age range to include patients over 65.

    Therefore, I cannot populate the table and answer all the questions based on the provided text. I will indicate where the information is missing.


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Metric, Threshold)Reported Device Performance
    Not provided in the document. The document asserts substantial equivalence to a predicate device rather than detailing specific performance criteria or the results of a new study proving these.Not provided in the document. No specific performance metrics or thresholds are given, nor are results of a study designed to meet such criteria.

    2. Sample size used for the test set and the data provenance

    • Sample size for test set: Not provided in the document.
    • Data provenance: Not provided in the document. No specific study data is presented, so the origin (country, retrospective/prospective) of any potential test data is not mentioned.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not provided in the document. Since no specific test set study is detailed, there's no information on ground truth establishment or expert involvement.


    4. Adjudication method for the test set

    Not provided in the document.


    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not provided in the document. The submission focuses on substantial equivalence to a previous version of the same AI device, not on comparing human readers with and without the AI.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The document describes the device as "decision-support software intended for assisting healthcare professionals," and states that "DreaMed Advisor Pro does not replace clinical judgement." This implies human-in-the-loop operation. No standalone (algorithm-only) performance is described or implied to have been studied for this 510(k) submission.


    7. The type of ground truth used

    Not provided in the document. No specific ground truth methodology is mentioned as a study proving performance is not detailed in this submission.


    8. The sample size for the training set

    Not provided in the document.


    9. How the ground truth for the training set was established

    Not provided in the document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191370

    Validate with FDA (Live)

    Date Cleared
    2019-07-18

    (57 days)

    Product Code
    Regulation Number
    862.1358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DreaMed Advisor Pro is a decision-support software intended for assisting healthcare professionals in the management of patients with Type 1 diabetes who:
    • use insulin pumps as their insulin delivery therapy;
    • monitor their glucose levels using CGM and/or self-management blood glucose meter;
    • are above the age of 6 and under 65 years old; and
    • use rapid acting U-100 insulin analogs in their pump.
    DreaMed Advisor Pro is indicated for use by healthcare professionals when analyzing continuous glucose monitoring (CGM), self-monitoring blood glucose (SMBG) and pump data to generate recommendations for optimizing a patient's insulin pump settings for basal rate, carbohydrate ratio (CR), and correction factor (CF); without considering the full clinical status of a particular patient. DreaMed Advisor Pro does not replace clinical judgement.

    Device Description

    DreaMed Advisor Pro is a software device that is designed to provide insulin therapy adjustment recommendations to physicians to assist in the management of diabetes for patients with Type 1 diabetes using an insulin pump, a continuous glucose monitoring (CGM) system and self-management blood glucose meter (SMBG).
    The DreaMed Advisor Pro gathers and analyzes information inputted through qualified Diabetes Management Systems (DMS), which collects biological input information from various diabetes devices. Diabetes device information required and used by DreaMed Advisor Pro includes glucose readings (either CGM sensor readings and/or capillary blood glucose measurements), insulin dosing logs, and meal data during daily routine care.
    Following data collection and analysis, the DreaMed Advisor Pro generates results containing summary data and recommendations for adjustments to the patient's insulin therapy parameters, including basal insulin delivery rate(s), insulin to carbohydrate ratio and correction factor (insulin sensitivity). DreaMed Advisor Pro may also advise behavioral changes. Results are sent to a qualified Diabetes Management Systems, which displays results to physicians and a report provided by DreaMed Diabetes. The physician can approve, reject or change the recommendations and issue the updated treatment plan to the patient.

    AI/ML Overview

    The DreaMed Advisor Pro is a decision-support software for healthcare professionals managing Type 1 diabetes patients. It generates recommendations for optimizing insulin pump settings based on continuous glucose monitoring (CGM), self-monitoring blood glucose (SMBG), and pump data.

    Here's an analysis of the acceptance criteria and study information provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state "acceptance criteria" in a quantitative performance table but discusses equivalence to a predicate device and clinical validity compared to expert recommendations.

    Feature / CharacteristicAcceptance Criteria (Implied / Compared to Predicate)Reported Device Performance and Assessment
    Agreement with Predicate Device (Retrospective Test)- High level of agreement with DEN170043 when comparing recommendations over similar datasets.- Retrospective tests showed a "high level of agreement" with the predicate device (DEN170043) for recommendations on similar data sets. - When sufficient data was available with simulated-SMBG, DreaMed Advisor Pro made similar recommendations to the predicate. - When insufficient data, DreaMed Advisor Pro did not recommend changes, mirroring the predicate's behavior without enough CGM data.
    Clinical Validity vs. Experts (SMBG data alone)- Recommendations in basal, CR, and CF plan (regarding direction of change) should be significantly as good as experts.- An additional retrospective clinical study found that DreaMed Advisor Pro's recommendations (when based on SMBG data alone) were "significantly as good as the recommendations of expert in the basal, CR and in the CF plan with regards to the direction of change." - This suggests the Advisor Pro's recommendations are similar to those from experienced healthcare professionals.
    Minimum Data Points for Analysis (Subject Device)- Minimum of 12 valid days.- Achieved: Minimum of 12 valid days required. A valid day consists of: - Minimum glucose data: At least 67% of CGM sensor readings per day (e.g., 192 samples for 5-minute interval sensor, 64 samples for 15-minute interval sensor), OR - At least 4 BG measurements a day separated by at least 160 minutes. - Minimum insulin pump data: At least 1 basal rate record and 1 bolus record. - Insulin pump settings at analysis within acceptable ranges: Basal rate (0.025-3 u/h), CR (3-70gr/u), CF (10-280gr/u), Bolus calculator targets (≤ 150 mg/dl).
    Input Data Specifications (Accuracy)- CGM sensors with regulatory approval demonstrating accuracy below MARD of 15%.- Achieved: Uses CGM with regulatory approval showing accuracy below MARD of 15%.
    Non-clinical tests (Design Validation, Human Factors, Software)- Performs according to stated intended use. - Human Factors validation documented per FDA Guidance. - All software test results fall within pre-determined specifications and acceptance criteria. - Special controls implemented and validated.- Achieved: Design validation testing and human factors study results confirmed performance per intended use. - Human Factors validation documented according to FDA Guidance (February 3, 2016). - Software evaluation included functional testing; all results within pre-determined specification parameters and acceptance criteria. - Special controls implemented and validated per DreaMed's software test plan.

    2. Sample Size and Data Provenance for the Test Set

    • Sample Size for Clinical Study: 15 patients.
    • Data Provenance: Retrospective clinical study. The document does not explicitly state the country of origin of the data.

    3. Number of Experts and Qualifications

    • Number of Experts: 17 experts.
    • Qualifications of Experts: They are described as "Healthcare Professional who work at leading centers with a wealth of experience in the field of diabetes and who are especially familiar with diabetes technology devices." No specific number of years of experience or physician titles (e.g., radiologist) are provided, as this is for diabetes management.

    4. Adjudication Method

    • Adjudication Method: The clinical study compared recommendations to examine the "level of agreement between one expert to his colleague (total of 136 pairs) versus the level of agreement between DreaMed Advisor Pro recommendations and experts (total of 17 pairs)." This implies a comparison against individual expert opinions, rather than a formal consensus-based adjudication method like 2+1 or 3+1. Each expert's recommendation was likely treated as a reference point for comparison.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • The document describes a comparative study where the device's recommendations were compared against experts. It's a "retrospective clinical study" involving 17 experts reviewing data for 15 patients. While it involves multiple readers (experts) and multiple cases (patients), it focuses on the agreement between the AI and human experts, and experts among themselves, rather than a direct MRMC study to quantify how much human readers improve with AI assistance vs. without AI assistance. The study concluded that the Advisor Pro's recommendations were "significantly as good as the recommendations of expert," implying equivalence, but not necessarily an "improvement effect size" in a human-in-the-loop scenario.

    6. Standalone Performance

    • Yes, a standalone performance assessment was done. The "Additional retrospective clinical study" evaluated the DreaMed Advisor Pro's recommendations based on SMBG data alone and compared these recommendations directly to those of human experts. This demonstrates the algorithm's performance in generating recommendations without real-time human input or modification.

    7. Type of Ground Truth Used

    • Ground Truth: Expert consensus (or rather, expert recommendations serving as a reference) was used. The study compared the device's recommendations against the recommendations made by the 17 human experts.

    8. Sample Size for the Training Set

    • The document does not explicitly state the sample size used for the training set. It focuses on the validation of the device.

    9. How the Ground Truth for the Training Set was Established

    • The document does not describe how the ground truth for any potential training set was established. The clinical study mentioned is a validation study comparing the device's output to expert recommendations, not a description of the training data or its ground truth establishment.