510(k) Data Aggregation

    K Number
    K243155

    Validate with FDA (Live)

    Date Cleared
    2025-02-11

    (134 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Single-Use Digital Flexible Ureteroscope (F-URS)(ZSR-URS-02, ZSR-URS-02, ZSR-URS-03, ZSR-URS-04) : This product is used in medical institutions, in conjunction with our electronic endoscope image processor. for imaging in examination, diagnosis or treatment of urinary system diseases.

    Endoscope Imaging Processor (ZSR-EOS10) : Applicable to medical institutions, which are connected with electronic endoscopic diagnosis and/or treatment/surgery, and effectively display images of the field of view areas of human body cavities observed by endoscopes on monitors.

    Device Description

    Single-Use Digital Flexible Ureteroscope (F-URS) (ZSR-URS-01, ZSR-URS-02, ZSR-URS-03, ZSR-URS-04) Single-Use Digital Flexible Ureteroscope (F-URS) is used in medical institutions, in conjunction with our electronic endoscope image processor, for imaging in examination, diagnosis or treatment of urinary system diseases. This device uses ethylene oxide (EO) sterilization process. This product consists of two main parts: an operating handle with directional control and connecting wires, as well as a flexible insertion tube.

    Electronic Endoscope Imaging Processor (ZSR-EOS10) Applicable to medical institutions, which are connected with electronic endoscopes during endoscopic diagnosis and/or treatment/surgery, and effectively display images of the field of view areas of human body cavities observed by endoscopes on monitors. The device is composed of aluminum alloy chassis and motherboard and power supply components.

    The Single-Use Digital Flexible Ureteroscope (F-URS) (ZSR-URS-01, ZSR-URS-02, ZSR-URS-03, ZSR-URS-04) and Electronic Endoscope Imaging Processor make up the video ureteroscope system.

    AI/ML Overview

    The provided text is for a 510(k) premarket notification for a Single-Use Digital Flexible Ureteroscope (F-URS) and an Electronic Endoscope Imaging Processor. This type of submission focuses on demonstrating substantial equivalence to a predicate device, rather than proving novel clinical effectiveness through extensive clinical trials. Therefore, the information regarding acceptance criteria and performance studies will differ significantly from what would be found in a submission for a new AI/software device that requires proving clinical benefit.

    Based on the provided text, here's an analysis of the acceptance criteria and supporting studies:

    1. Table of Acceptance Criteria and Reported Device Performance

    The FDA clearance for this device is based on substantial equivalence to existing predicate devices, not on specific performance metrics established as acceptance criteria for clinical efficacy. The "acceptance criteria" here refer to meeting recognized standards for medical devices of this type, ensuring safety, and demonstrating that any differences from the predicate do not raise new questions of safety or effectiveness.

    Performance CharacteristicAcceptance Criteria (Standard Reference)Reported Device Performance (Compliance)Notes from Document
    Performance TestingISO 16926-6:2014ConformsEndoscope Image Quality
    ISO 8600-5:2020ConformsEndoscope Image Quality
    IEC 62471:2006ConformsPhotobiological Safety
    ISO 8600-1:2015ConformsEndoscope General Requirements
    ISO 8600-4:2014ConformsEndoscope Test Methods
    ISO 12233:2017ConformsDigital Image Still Camera Resolution
    ISO 15739:2017ConformsDigital Still Camera Noise
    ISO/CIE 11664-4ConformsColor Performance
    Wang, et al. (2016)ConformsLocal Magnification Method for Geometric Distortion
    Wang et al. (2017)ConformsField of View Measurement
    Wei-Chung Cheng (2023)ConformsColor Performance Analyzer
    BiocompatibilityFDA Guidance "Use of International Standard ISO 10993-1"ConformsCytotoxicity, Sensitization, Irritation, Acute Systemic, Pyrogenicity
    Sterility & Shelf-lifeISO 11135:2014ConformsEthylene Oxide Sterilization
    ISO 11737-1:2018ConformsSterilization of Healthcare Products - Microbiological Methods - Part 1: Determination of a Population of Microorganisms on Products
    ISO 11737-2:2019ConformsSterilization of Healthcare Products - Microbiological Methods - Part 2: Tests on Sterility Assessed Through Microorganism Detection
    ISO 10993-7:2008ConformsEthylene Oxide Sterilization Residuals
    ASTM F1980-2016ConformsAccelerated Aging
    ASTM F88/F88M-15ConformsSeal Strength
    ASTM D4169-23e1ConformsPerformance Testing of Shipping Containers and Systems

    Discussion of Differences (from Comparison Table, if differences existed):
    The document states for "Maximum insertion portion width(mm)" and "Field of view (degree)" that these are "Similar" or "Same" after analysis, concluding that "Only differences in specifications and dimensions. All the performance was tested and the results met the standard requirements, this difference will not raise any issues in safety and effectiveness." This indicates that any numerical differences in these parameters were evaluated against the relevant standards and found to be acceptable.

    2. Sample size used for the test set and the data provenance

    The document explicitly states: "No clinical study is included in this submission."

    Therefore, there is no "test set" in the context of clinical data. The testing performed was non-clinical bench testing to demonstrate compliance with recognized industry standards and evaluate engineering performance, biocompatibility, and sterilization effectiveness.

    • Sample Size for Bench Testing: The document does not specify the exact number of units or samples used for each non-clinical test (e.g., how many ureteroscopes were tested for bending angle, how many samples for biocompatibility). This level of detail is typically found in the full test reports, not the 510(k) summary.
    • Data Provenance: The data provenance is from non-clinical laboratory and bench testing, likely conducted by the manufacturer or accredited testing facilities. There is no mention of country of origin for this testing, but it can be inferred the testing supports a device manufactured by Dongguan ZSR Biomedical technology Company Limited in the PEOPLE'S REPUBLIC OF CHINA.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. As no clinical study was conducted, there was no clinical "test set" requiring expert ground truth establishment. The "ground truth" for the non-clinical tests is defined by the objective metrics and thresholds established in the referenced international standards (e.g., ISO, IEC, ASTM).

    4. Adjudication method for the test set

    Not applicable. There was no clinical test set requiring an adjudication method.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a physical medical instrument (ureteroscope and imaging processor), not an AI/software device. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a physical medical instrument, not a standalone algorithm.

    7. The type of ground truth used

    The "ground truth" for this 510(k) submission is derived from:

    • International Standards and Recognized Test Methods: For performance, biocompatibility, and sterility, the ground truth is compliance with the specifications and thresholds defined in the referenced standards (e.g., ISO, IEC, ASTM).
    • Predicate Device Characteristics: For determining substantial equivalence, the technological characteristics and performance of the legally marketed predicate device (K230200) serve as a baseline for comparison.

    8. The sample size for the training set

    Not applicable. This device is a physical medical instrument, and no machine learning algorithm development (which would require a training set) is mentioned or implied.

    9. How the ground truth for the training set was established

    Not applicable. There was no training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241181

    Validate with FDA (Live)

    Date Cleared
    2024-08-02

    (95 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Disposable Ureteral Guide Sheath is used to establish a conduit during endoscopic urological procedures facilitating the passage of endoscopes and other instruments into the urinary tract

    Device Description

    The propose device, Disposable Ureteral Guide Sheath is used to establish a conduit during endoscopic urological procedures facilitating the passage of endoscopes and other instruments into the urinary tract. This device is divided into 4 types: Straight type (ZSR-UA), Y type (ZSR-UAY), W type (ZSR-UAW), Cross type (ZSR-UAC). The device is composed of guide sheath and dilator.The guide sheath consists of guide sheath tube and connector (straight, Y-shaped, W-shaped and cross-shaped). The proposed devices are sterilized by Ethylene Oxide Gas to achieve a SAL of 10-6 and supplied sterility maintenance package which could maintain the sterility of the device during the shelf life of 3 years.

    AI/ML Overview

    The provided text describes the 510(k) premarket notification for a medical device called the "Disposable Ureteral Guide Sheath." It primarily focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance and biocompatibility testing. The document does not detail a study proving the device meets acceptance criteria related to AI/algorithm performance or human reader improvement.

    Therefore, I cannot provide information on acceptance criteria for AI performance, sample sizes for AI test sets, number of experts, adjudication methods, MRMC studies, standalone algorithm performance, or ground truth establishment for AI. These sections are not relevant to the provided text.

    However, I can extract information regarding the non-clinical performance testing acceptance criteria and results as described in the document.

    1. Table of Acceptance Criteria and Reported Device Performance

    For non-clinical performance testing, the document refers to compliance with standards. The 'Discussion' section under 'Comparison of technological characteristics with the predicate devices' (Table 1) provides some insight into the performance aspects considered, although explicit numerical acceptance criteria are not always stated, rather the outcome of testing.

    Acceptance Criteria CategorySpecific Test/CharacteristicAcceptance Criteria (Implicit from discussion)Reported Device Performance (Implicit from discussion)
    Performance - Bending ResistanceGuiding sheath tube and dilating tube bending (90° in both directions, 20 repetitions)Tube body free of cracks, creases, and fractures; coating free of falling off; steel wire not separated from inner/outer rubber layers."The guiding sheath tube and the dilating tube were bent 90 ° in both directions... After 20 times of repetition, the tube body was free of cracks, creases, cracks and fractures, the coating was free of falling off, and the steel wire was not separated from the inner and outer rubber layers." (Meets criteria)
    Performance - Coefficient of Friction (Hydrophilic)After dipping in water, friction forceNot more than 0.5 N for static friction; average dynamic friction force of 25 repeated tests not greater than 0.5 N."After being dipped in water, the surface is smooth, and the friction force is not more than 0.5 N; The average dynamic friction force of 25 repeated tests shall not be greater than 0.5 N." (Meets criteria)
    Performance - Peak Tensile ForceJoint between guiding sheath tube/dilating tube and connectorAble to bear a force of ≥ 20 N for 15s without breaking."The joint between the guiding sheath tube and the tube body of the dilating tube and the connector shall be able to bear a force of ≥ 20 N and shall not break for 15 s;" (Meets criteria)
    Performance - Fracture Force (Locked connector)Guiding sheath tube connector and expansion tube connector lockedMinimum fracture force ≥ 15N for 15s without breaking."The fracture force test shall be carried out when the guiding sheath tube connector and the expansion tube connector are locked. The minimum fracture force shall be ≥ 15N and shall not break for 15 s." (Meets criteria)
    BiocompatibilityCytotoxicity, Sensitization, Irritation, Acute Systemic, PyrogenicityCompliance with ISO 10993-1."Biocompatibility of the Disposable Ureteral Guide Sheath was evaluated in accordance with the FDA guidance "Use of International Standard ISO 10993-1"" and lists the specific tests. Implies successful completion ("this difference will not raise any issues in safety and effectiveness").
    Sterility & Shelf-lifeSterility Assurance Level (SAL), Packaging IntegritySAL of 10-6 upon sterilization; maintenance of sterility for 3 years shelf life."sterilized by Ethylene Oxide Gas to achieve a SAL of 10-6 and supplied sterility maintenance package which could maintain the sterility of the device during the shelf life of 3 years." (Meets criteria)
    General PerformanceOverall performance for all physical characteristics not explicitly detailed aboveMeets requirements of relevant standards (e.g., EN 1618 for catheters)."All performance of the subject device has been tested according to relevant standards and meets the requirements of the standards..."

    2. Sample Size Used for the Test Set and Data Provenance

    This document describes non-clinical engineering and bench testing, not a clinical study involving a "test set" of patient data in the way an AI/ML device would.

    • Sample Size: Not explicitly stated as a grand total for testing. For specific tests like "Coefficient of Friction," it mentions "25 repeated tests." For "Bending Resistance," it mentions "20 times of repetition."
    • Data Provenance: This is bench test data, not patient data. The country of origin for the manufacturing company is Dongguan ZSR Biomedical technology Company Limited, China. The testing would have been conducted as part of their device development and validation process. It is neither retrospective nor prospective in the context of patient data studies; it's product validation testing.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. This is not a study involving expert readers establishing ground truth for diagnostic accuracy, but rather bench testing against engineering specifications and industry standards.

    4. Adjudication Method for the Test Set

    Not applicable. This is not a study involving human interpretation or clinical adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No. This document does not pertain to an AI-assisted diagnostic device, nor does it describe an MRMC study.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    No. This document does not pertain to an algorithm, AI, or software device. It is for a physical medical device.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance testing described would be the engineering specifications and industry standards (e.g., specific force values for tensile strength, visual inspection for defects after bending, a defined Sterility Assurance Level). For biocompatibility, the 'ground truth' is compliance with the ISO 10993 series of standards.

    8. The Sample Size for the Training Set

    Not applicable. This is for a physical device, not an AI/ML algorithm requiring a training set.

    9. How the Ground Truth for the Training Set was Established

    Not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device