Found 2 results

510(k) Data Aggregation

    K Number
    K091760

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2009-07-20

    (34 days)

    Product Code
    Regulation Number
    876.5540
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DermaPort Ported Vascular Access System (PVAS™) is indicated for long-term (greater than 30 days) vascular access for hemodialysis and apheresis. The system is inserted percutaneously and typically placed in the internal jugular vein of an adult patient. The subclavian vein is an alternate catheter insertion site.

    Device Description

    The Ported Vascular Access System (PVAS™) has been developed to support central vascular access for hemodialysis and apheresis. This application is for the addition of a 15.5F catheter to the PVAS system and a dilating lead-in to replace the sheath during insertion. The PVAS port consists of a percutaneous tubular conduit, through which a standard 14.5F or 15.5F polyurethane hemodialysis catheter enters the subcutaneous tunnel. An integral seal surrounds the catheter and prevents microbial migration along the catheter. The PVAS port is enclosed by a silicone anchor that braces the assembly to the skin, and an associated brake holds the catheter in place within the port. A tissue integrating biomaterial surrounds the port, providing anatomical fixation and prevention of microbial migration in a manner analogous to the Dacron cuff of a tunneled catheter.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called the DermaPort Ported Vascular Access System (PVAS™). This document is primarily focused on demonstrating substantial equivalence to a predicate device, rather than providing a detailed study report with specific acceptance criteria and performance metrics in the format of a diagnostic or AI-driven device.

    Therefore, many of the requested elements for a diagnostic device study description (such as sample sizes for test/training sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, and how ground truth was established for training sets) are not applicable or available in this type of regulatory submission.

    The "acceptance criteria" here are implicitly related to the safety and functionality of the physical device modifications remaining within acceptable limits compared to the predicate, as evidenced by various engineering and animal tests, rather than diagnostic performance metrics.

    Here is the information that can be extracted and a clear indication of what is not available based on the provided text:

    Acceptance Criteria and Reported Device Performance

    Note: The acceptance criteria for this type of device (physical medical device, not a diagnostic algorithm) are typically focused on engineering and functional specifications, material compatibility, and biological safety. The "reported device performance" refers to the verification that these specifications are met following modifications. Specific numerical thresholds (e.g., for safety margins, flow rates, or biomechanical strength) are not detailed in this summary.

    Acceptance Criteria CategoryReported Device Performance (Verification of Changes)
    Functional / Insertion PerformanceVerified that removal of the sheath, addition of dilating lead-in, and change in mesh geometry did not impact the function, performance, or safety of the device. (Tested via insertion testing).
    Biomechanical / Tissue InteractionVerified via histopathological analysis of the mesh following implantation in a chronic animal model and biomechanical testing of tissue ingrowth. Confirmed mesh to port removal force for modified geometry.
    Catheter / Port RetentionVerified through catheter/port retention testing.
    Microbial BarrierVerified through microbial ingress testing.
    Flow Performance (New Catheter Sizes)Verified through flow versus pressure testing for new 15.5F catheter size.
    Biocompatibility / Accessory FunctionalityVerified through functional/biocompatibility testing for new accessories (e.g., new dilator, added suture, replaced injection caps).
    Overall Safety and Effectiveness Comparison"The modified PVAS does not raise new questions of safety or effectiveness." (Conclusion from the evaluation as required by risk analysis and Design Control requirements). This implies substantial equivalence to the predicate device in terms of safety and effectiveness.

    Study Details (Information Not Applicable or Available in the Provided Text)

    1. Sample sizes used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

      • N/A. This document describes engineering and animal studies for device modifications, not a clinical diagnostic performance study. Specific sample sizes for each test (insertion, histopathology, biomechanical, retention, microbial ingress, flow-pressure, biocompatibility) are not provided. The chronic animal model mentioned implies prospective animal testing, but details are absent.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • N/A. This device is a physical medical device, not an AI or diagnostic tool requiring ground truth established by human experts in the conventional sense. Material and engineering standards/experts would be involved in defining test methods and interpreting results, but not in setting "ground truth" for a diagnostic test set.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • N/A. Not applicable to the type of device and studies described.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • N/A. This is not an AI-assisted diagnostic device.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • N/A. This is a physical medical device, not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • N/A (in the diagnostic sense). For this device, ground truth would be defined by engineering specifications, material standards, physiological parameters in animal models (e.g., successful tissue ingrowth in histopathology), and regulatory safety requirements. It's not "ground truth" for a diagnostic decision.
    7. The sample size for the training set:

      • N/A. This device does not use a "training set" in the context of machine learning or algorithms. The studies are for design verification and validation of physical modifications.
    8. How the ground truth for the training set was established:

      • N/A. As above, no training set or ground truth in this context.
    Ask a Question

    Ask a specific question about this device

    K Number
    K071202

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2007-11-30

    (213 days)

    Product Code
    Regulation Number
    876.5540
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DermaPort Percutaneous Vascular Access System (PVAS™) is indicated for long-term (greater than 30 days) vascular access for hemodialysis and apheresis. The system is inscrted percutaneously and the catheter is typically placed in the internal jugular vein of an adult patient. The subclavian vein is an alternate catheter insertion site.

    Device Description

    The DermaPort Percutaneous Vascular Access System (PVAS) is designed to facilitate catheter placement, reposition, and exchange procedures while maintaining the catheter attachment, bacterial barrier, and fixation functions of the predicate catheter fibrous cuff. The main component of the PVAS is a metal port which is implanted into the subcutaneous tunnel at the catheter exit site on the chest wall. The hemodialysis catheter passes through the metal port which acts as a percutaneous conduit, into the subcutaneous tunnel, and then into the central venous system in the usual fashion. The metal surface of the PVAS port has a porous, tissue integrating coating which allows ingrowth of tissue to anchor the PVAS port. The PVAS port holds the hemodialysis catheter in place.

    The DermaPort Percutaneous Vascular Access System (PVAS) consists of the following types of components:

      1. Implanted Hemodialysis 14.5 F Catheter (24 cm, 28 cm or 32 cm lengths)
    • Guidewire; 0.038 inch (70 cm or 100 cm lengths) 2.
      1. 16F Tcaraway Set Griplock Hub
      1. 12F Polyethylene Dilator
    • న్. 14F Polyethylene Dilator
      1. Clear Female Dust Cover
      1. Injection Caps
      1. 18 GA x 2.7" Cyrolite Introducer Needle
      1. Tunneler with Tri ball tip
      1. Tunneler Sleeve
      1. DermaPort Blade
      1. Commercially available alcohol pad
      1. Commercially available adhesive wound dressing
      1. Peel-away Sheath
      1. DermaPort Percutaneous Vascular Access System (PVAS) Port

    The catheter is identical to the Hemolilow catheter, with the exception that the fabric cuff on the HemoFlow catheter is omitted. The HemoFlow catheter is cleared to market by the FDA via 510(k) number K994105.

    The Percutancous Vascular Access System (PVAS™) has been developed to support central vascular access for hemodialysis and apheresis. The PVAS port consists of a percutaneous tubular conduit, through which a standard 14.5F polyurethane hemodialysis catheter enters the subcutaneous tunnel. An integral seal surrounds the catheter and prevents microbial migration along the catheter. The PVAS port is enclosed by a silicone anchor that braces the assembly to the skin, and an associated brake holds the catheter in place within the port. A tissue integrating biomaterial surrounds the port, providing anatomical fixation and prevention of microbial migration in a manner analogous to the fabric cuff of a tunneled catheter.

    AI/ML Overview

    The provided text is a 510(k) summary for the DermaPort Percutaneous Vascular Access System (PVAS). It describes the device, its intended use, and its substantial equivalence to a predicate device. However, it does not contain information about specific acceptance criteria, a detailed study proving performance against those criteria, or the specific elements requested in your prompt (e.g., sample sizes, expert qualifications, adjudication methods, MRMC studies, standalone performance, or training set details).

    The document states: "The PVAS technical characteristics and construction are substantially equivalent to the predicate device. The difference in construction was qualified with bench and animal testing." This implies that the 'study' conducted was focused on demonstrating substantial equivalence through bench and animal testing to the predicate device (Medcomp Hemo-Flow Catheter, K994105, and Med-Conduit Inc. HemoCath II, K062901), rather than a specific clinical trial with defined acceptance criteria for the new device.

    Therefore, I cannot populate the table or provide the requested details based on the provided text. The document is primarily a regulatory submission demonstrating equivalence, not a detailed study report.