Search Filters

Search Results

Found 83 results

510(k) Data Aggregation

    K Number
    K251614

    Validate with FDA (Live)

    Date Cleared
    2026-02-06

    (255 days)

    Product Code
    Regulation Number
    880.6850
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K253959

    Validate with FDA (Live)

    Device Name
    Primevision 3D
    Manufacturer
    Date Cleared
    2026-02-05

    (57 days)

    Product Code
    Regulation Number
    892.1750
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K253009

    Validate with FDA (Live)

    Device Name
    DS Core Detect
    Date Cleared
    2026-01-07

    (110 days)

    Product Code
    Regulation Number
    892.2070
    Age Range
    22 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DS Core Detect is a concurrent read, computer assisted detection software intended to aid the dentist in the incidental detection of permanent teeth that may be associated with periapical radiolucencies in CBCT images. The device is not intended as a replacement for a complete dentist's review or a replacement of their clinical judgment. The device is to be used by licensed dentists. The device is designed for patients who already have CBCT data obtained for other reasons. DS Core Detect does not generate X-ray images and does not provide an indication for taking such images.

    The device is intended for adults aged 22 years and older with permanent teeth.

    Device Description

    The DS Core Detect device is a cloud-based SaMD that is a Computer Aided Detection "CADe" Machine Learning "ML" enabled device for the aid in incidental detection of permanent teeth that may have periapical radiolucency "PARL" on a CBCT image. The device is designed for patients who already have CBCT data obtained from a CBCT imaging system for other reasons. DS Core Detect does not generate X-ray images and does not provide an indication for taking such images.

    The device itself is accessed by the dental practitioner through their dental image viewer. From within the dental viewer the user can view the CBCT with results from the subject device. The device will provide a list of teeth that may potentially have PARL and a corresponding PARL "map" to visualize where the PARL is detected. The user has completely autonomy to confirm or reject a tooth that is flagged by the device as potentially PARL positive.

    The intended users of the device are trained and licensed dentists. The intended patient population for the device is adult patients with permanent teeth at least age 22.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study details for the DS Core Detect device, based on the provided FDA 510(k) clearance letter:


    Acceptance Criteria and Device Performance for DS Core Detect

    The DS Core Detect device has two operating points: High sensitivity and Standard sensitivity. The acceptance criteria are based on the device's standalone performance in terms of sensitivity and specificity, and augmented by a Multi-Reader Multi-Case (MRMC) study to evaluate the impact on human reader performance.

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document does not explicitly state "acceptance criteria" in a pass/fail format with exact numerical thresholds. However, the performance metrics reported from the standalone study and the MRMC study implicitly define the expected performance for clearance. The key performance indicators are Sensitivity and Specificity at different operating points for the standalone performance, and the improvement in AUC, Sensitivity, and Specificity for human readers when aided by the device.

    Table 1: DS Core Detect Performance Metrics

    Metric TypeOperating PointReported Performance95% Confidence Interval
    Standalone PerformanceHigh sensitivitySensitivity: 0.78[0.74; 0.81]
    Specificity: 0.93[0.92; 0.94]
    Standard sensitivitySensitivity: 0.66[0.62; 0.70]
    Specificity: 0.97[0.97; 0.98]
    MRMC (Reader Performance)Unaided ReadersAUC: 0.415[0.279, 0.550]
    Sensitivity: 0.421[0.281, 0.562]
    Specificity: 0.962[0.928, 0.995]
    MRMC (Aided Reader Performance)Aided ReadersAUC: 0.639[0.529, 0.749]
    Sensitivity: 0.649[0.535, 0.763]
    Specificity: 0.946[0.915, 0.976]
    MRMC (Improvement with Aid)Difference (Aided vs Unaided)AUC: 0.224[0.124, 0.324]
    Sensitivity: 0.227[0.124, 0.330]
    Specificity: -0.016[-0.034, 0.002]

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Test Set): The standalone study used 306 CBCTs. The MRMC study does not explicitly state the number of cases but refers to "Tooth Level AUC results," implying that the unit of analysis is individual teeth within the CBCTs.
    • Data Provenance: The data consisted of patients from various clinical sites across the U.S. It is retrospective, as the device is designed for patients who already have CBCT data obtained for other reasons. The dataset included adult patients aged 22 and older with permanent teeth.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    The document states that the standalone study assessed performance compared to a "consensus ground truth." However, it does not specify the number of experts used to establish this ground truth, nor their specific qualifications (e.g., "radiologist with 10 years of experience").

    4. Adjudication Method for the Test Set

    The document mentions "consensus ground truth" for the standalone study. This implies an adjudication process where multiple experts collectively determine the ground truth. However, the specific method (e.g., 2+1, 3+1, majority vote, etc.) is not described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Yes, an MRMC comparative effectiveness study was done. The document explicitly states: "The MRMC study evaluated reader performance with and without the assistance of the device, in a fully crossed study design."
    • Effect Size of Improvement:
      • AUC Improvement: Human readers improved by 0.224 (from 0.415 unaided to 0.639 aided), with a 95% CI of [0.124, 0.324].
      • Sensitivity Improvement: Human readers improved by 0.227 (from 0.421 unaided to 0.649 aided), with a 95% CI of [0.124, 0.330].
      • Specificity Change: Human readers experienced a slight decrease in specificity of -0.016 (from 0.962 unaided to 0.946 aided), with a 95% CI of [-0.034, 0.002].

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Yes, a standalone study was done. The document states: "The standalone study assessed the performance of the device compared to a consensus ground truth." The performance metrics (Sensitivity and Specificity) for the "High sensitivity" and "Standard sensitivity" operating points are reported from this standalone study.

    7. The type of ground truth used

    The ground truth used for both the standalone study and likely as the reference for the MRMC study was expert consensus. It is specifically referred to as "consensus ground truth."

    8. The sample size for the training set

    The document does not specify the sample size for the training set. It only details the test set used for performance evaluation.

    9. How the ground truth for the training set was established

    The document does not specify how the ground truth for the training set was established.

    Ask a Question

    Ask a specific question about this device

    K Number
    K252343

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-12-09

    (134 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K252248

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-26

    (131 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    CEREC Tessera Abutment System is intended for use in partially or fully edentulous mandibles and maxillae in support of single cement-retained restorations.

    For BH 3.0 S, NC Variobase C 3.3, Camlog 3.3 S and S BL 3.3 L titanium bases, the indication is restricted to the replacement of single lateral incisors in the maxilla and lateral and central incisors in the mandible.

    The system comprises three parts:

    • CEREC Tessera Abutment Block
    • TiBase
    • CAD/CAM system

    The CEREC Tessera ceramic structure cemented to the TiBase is recommended for two-piece hybrid abutments for single tooth restorations and hybrid abutment crowns, used in conjunction with endosseous dental implants.

    The compatible Implant systems, titanium bases and CAD/CAM systems are shown below:

    Implant Systems:

    • Dentsply Sirona: Astra Tech OsseoSpeed TX, Ankylos
    • BioHorizons: Internal connection
    • Nobel Biocare: Replace, Replace Select, Nobel Active, NobelReplace Concial Connection, Branemark, NobelSpeedy Groovy
    • Straumann: Tissue Level, Bone Level
    • Thommen Medical: Element, Contact
    • Osstem/Hiossen: Osstem TS, (USA:Hiossen ET)
    • Zimmer/Biomet: External hex, Certain, Tapered Screw-Vent
    • MIS: C1 Conical connection, V3 Conical connection, SEVEN internal hex, M4 internal hex
    • Altatec - Camlog
    • MIS: C1 Conical connection (NP and WP), V3 Conical connection, SEVEN internal hex, M4 internal hex

    CAD/CAM Systems:

    • Sirona Dental CAD/CAM System

    Titanium Bases:

    Implant: AstraTech Osseospeed TX

    • Platform: 3.5/4.0; TiBase AT TX 3.5/4.0 GH1 L; Reference 6598093; Size L
    • Platform: 4.5/5.0; TiBase AT TX 4.5/5.0 GH1 L; Reference 6598101; Size L
    • Platform: 3.5/4.0; TiBase AT OS 3.5/4.0 GH1 L; Reference 6282532; Size L
    • Platform: 4.5/5.0; TiBase ATOS 4.5/5.0 GH1 L; Reference 6282540; Size L

    Implant: Ankylos

    • Platform: C/X; TiBase ANK C/ GH 1 S; Reference 6586528; Size: S

    • Platform: C/X; TiBase ANK C/ GH 2 S; Reference 6586536; Size: S

    • Platform: C/X; TiBase ANK /X GH 1 S; Reference 6586544; Size: S

    • Platform: C/X; TiBase ANK /X GH 2 S; Reference 6586551; Size: S

    Manufacturer: M.I.S. Implants

    Implant: C1 Conical Connection

    • Platform: NP; CN-TB001 C1 NP GH 0.5; Reference CN-TB001; Size: L
    • Platform: NP; CN-B015 C1 NP GH 1.5; Reference CN-TB015; Size: L

    Implant: V3 Conical Connection

    • Platform: NP; VN-TB001 V3 NP GH 0.5; Reference VN-TB001; Size: L
    • Platform: NP; VN-TB015 V3 NP GH 1.5; Reference VN-TB015; Size: L

    Implant: V3 Conical Connection / C1 Conical Connection

    • Platform: SP; CS-TB001 SP GH 0.5; Reference CS-TB001; Size: L
    • Platform: SP; CS-TB015 SP GH 1.5; Reference CS-TB015; Size: L
    • Platform: SP; CS-TB030 SP GH 3; Reference CS-TB030; Size: L

    Implant: C1 Conical Connection

    • Platform: WP; CW-TB001 C1 WP GH 0.5; Reference CW-TB001; Size: L
    • Platform: WP; CW-TB015 C1 WP GH 1.5; Reference CW-TB015; Size: L
    • Platform: WP; CW-TB030 C1 WP GH 3; Reference CW-TB030; Size: L

    Implant: SEVEN internal hex, M4 internal hex

    • Platform: NP; MN-TB001 INT HEX NP GH 0.5; Reference MN-TB001; Size: L
    • Platform: NP; MN-TBC15 INT HEX NP GH 1.5; Reference MN-TBC15; Size: L
    • Platform: SP; MD-TB001 INT HEX SP GH 0.5; Reference MD-TB001; Size: L
    • Platform: SP; MD-TBC15 INT HEX SP GH 1.5; Reference MD-TBC15; Size: L
    • Platform: SP; MD-TBC30 INT HEX SP GH 3; Reference MD-TBC30; Size: L
    • Platform: WP; MW-TB001 INT HEX WP GH 0.5; Reference MW-TB001; Size: L
    • Platform: WP; MW-TBC15 INT HEX WP GH 1.5; Reference: MW-TBC15; Size: L
    • Platform: WP; MW-TBC30 INT HEX WP GH 3; Reference: MW-TBC30; Size: L

    Manufacturer: BioHorizons

    Implant: Internal Connection

    • Platform: 3.0; TiBase BH 3.0 GH 1 S; Reference 6532779; Size: S
    • Platform: 3.5; TiBase BH 3.5 GH 1 L; Reference 6532894; Size: L
    • Platform: 4.5; TiBase BH 4.5 GH 1 L; Reference 6532951; Size: L
    • Platform: 5.7; TiBase BH 5.7 GH 1 L; Reference 6536242; Size: L

    Manufacturer: Nobel Biocare

    Implant: Replace, Replace Select

    • Platform: NP; TiBase NB RS 3.5 GH 1 L; Reference 6282474; Size: L
    • Platform: RP; TiBase NB RS 4.3 GH 1 L; Reference 6282482; Size: L
    • Platform: WP; TiBase NB RS 5.0 GH 1 L; Reference 6282490; Size: L
    • Platform: 6.0; TiBase NB RS 6.0 GH 1 L; Reference 6282508; Size: L

    Implant: Nobel Active, Nobel Replace Conical Connection

    • Platform: NP; TiBase NB A 4.5 GH 1 L; Reference 6308188; Size: L
    • Platform: RP; TiBase NB A 5.0 GH 1 L; Reference 6308253; Size: L

    Implant: Branemark

    • Platform: NP; TiBase NB B 3.4 GH 1 L; Reference 6282516; Size: L

    Implant: NobelSpeedy Groovy

    • Platform: RP; TiBase NB B 4.1 GH 1 L; Reference 6282524; Size: L

    Manufacturer: Straumann

    Implant: Tissue Level

    • Platform: RN (4.8 mm); TiBase SSO 4.8 GH 1 L; Reference 6284249; Size: L
    • Platform: WN (6.5 mm); TiBase SSO 6.5 GH 1 L; Reference 6284256; Size: L

    Implant: Bone Level

    • Platform: NC (3.3 mm); TiBase S BL 3.3 GH 1 L; Reference 6308154; Size: L
    • Platform: RC (4.1 mm/ 4.8 mm); TiBase S BL C 4.1 GH 1 L; Reference 6308337; Size: L

    Manufacturer: Thommen Medical

    Implant: Element, Contact

    • Platform: 3.5; TiBase TM 3.5 GH 1 S; Reference 6531854; Size: S
    • Platform: 4; TiBase TM 4 GH 1 S; Reference 6532829; Size: S
    • Platform: 4.5; TiBase TM 4.5 GH 1 S; Reference 6532837; Size: S
    • Platform: 5; TiBase TM 5 GH 1 S; Reference 6544360; Size: S
    • Platform: 6; TiBase TM 6 GH 1 S; Reference 6544378; Size: S

    Manufacturer: Osstem / Hiossen

    Implant: Osstem TS (US Hiossen ET)

    • Platform: Mini; TiBase O TS 3.5 GH 1 L; Reference 6527035; Size: L
    • Platform: Regular; TiBase O TS 4.0 GH 1 L; Reference 6527043; Size: L

    Manufacturer: Zimmer / Biomet

    Implant: External hex

    • Platform: 3.4; TiBase BO 3.4 GH 1 L; Reference 6282557; Size: L
    • Platform: 4.1; TiBase BO 4.1 GH 1 L; Reference 6282565; Size: L
    • Platform: 5.0; TiBase BO 5.0 GH 1 L; Reference 6282573; Size: L

    Implant: Certain

    • Platform: 3.4; TiBase B C 3.4 GH 1 S; Reference 6308048; Size: S
    • Platform: 4.1; TiBase BC 4.1 GH 1 L; Reference 6308097; Size: L
    • Platform: 5.0; TiBase BC 5.0 GH 1 L; Reference 6308121; Size: L

    Implant: Tapered Screw-Vent

    • Platform: 3.5; TiBase Z TSV 3.5 GH 1 L; Reference 6282581; Size: L
    • Platform: 4.5; TiBase Z TSV 4.5 GH 1 L; Reference 6282599; Size: L
    • Platform: 5.7; TiBase Z TSV 5.7 GH 1 L; Reference 6282607; Size: L

    Manufacturer: Straumann

    Implant: Bone Level

    • Platform: NC (3.3 mm); TiBase NC Variobase C 3.3 GH 1; Reference 220.043; Size: S
    • Platform: RC (4.1 mm/ 4.8 mm); TiBase RC Variobase C 4.1 GH 1; Reference 220.044; Size: L

    Manufacturer: Altatec GmbH-Camlog

    Implant: Camlog

    • Platform: 3.3; CAMLOG Titanium Base CAD/CAM, for Ø 3.3 mm GH 0.4; Reference K2244.3348; Size S
    • Platform: 3.8; CAMLOG Titanium Base CAD/CAM, for Ø 3.8 mm GH 0.3; Reference K2244.3848; Size: S
    • Platform: 4.3; CAMLOG Titanium Base CAD/CAM, for Ø 4.3 mm GH 0.3; Reference K2244.4348; Size: S
    • Platform: 5.0; CAMLOG Titanium Base CAD/CAM, for Ø 5.0 mm GH 0.3; Reference K2244.5048; Size: L
    • Platform: 6.0; CAMLOG Titanium Base CAD/CAM, for Ø 6.0 mm GH 0.3; Reference K2244.6048; Size: L
    Device Description

    The proposed CEREC Tessera Abutment System is a modification of the previously cleared CEREC Tessera Abutment Block (K221402). The proposed CEREC Tessera Abutment Blocks are intended for fabrication of single cement-retained restorations. The proposed CEREC Tessera Abutment System (with the additional TiBase and Implant System compatibilities and change in wall thickness) is comprised of the CEREC Tessera Abutment Block, applicable TiBase, and CAD/CAM systems in both chairside (CEREC chairside software) and labside (inLab labside software) use. The CEREC Tessera Abutment Blocks are not provided as the finished, fully assembled dental implant medical device. The CEREC Tessera Abutment Blocks are materials supplied to dental professionals that must be further processed/manufactured using CAD/CAM technology and they are not intended to be reused as in the context of direct patient-applied devices and materials.

    The CEREC Tessera Abutment Blocks are designed with a pre-drilled screw access channel and anti-rotation feature. The design allows for fabrication of a ceramic structure used to create 2-piece hybrid abutments and hybrid abutment crowns cemented to a TiBase used with dental implant systems. The patient-specific ceramic structure is then cemented to a TiBase to create the two-piece abutment which constitutes the final finished medical device. The following patient-specific ranges for CAD/CAM fabrication of the abutments are:

    • Maximum angulation of 20°
    • Minimal wall thickness of 0.5 mm
    • Gingival height ranges from 0.5 mm -3.0 mm
    • Minimum abutment post height (i.e. length above the gingival height) of >4 mm
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251205

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-21

    (217 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Atlantis Abutment & Atlantis Abutment Milling
    The Atlantis Abutment and Atlantis Abutment Milling are intended for use with an endosseous implant to support a prosthetic device in a partially or completely edentulous patient. It is intended for use to support single and multiple tooth prosthesis, in the mandible or maxilla. The Atlantis Abutment screw is intended to secure the Atlantis Abutment to the endosseous implant.

    Atlantis Crown Abutment
    The Atlantis Crown Abutment is intended for use with an endosseous implant to function as a substructure that also serves as the final restoration, in a partially or completely edentulous patient. The Atlantis Abutment screw is intended to secure the Atlantis Crown Abutment to the endosseous implant.

    Atlantis Conus Abutment
    The Atlantis Conus Abutment is intended for use with an endosseous implant to support a prosthetic device in partially or completely edentulous patients. It is intended for use to support a removable multiple tooth prosthesis, in the mandible or maxilla. The prosthesis is an attachment-retained by friction fit to the abutment. The Atlantis Abutment screw is intended to secure the Atlantis Conus Abutment to the endosseous implant.

    Atlantis Healing Abutment
    The Atlantis Healing Abutment is intended for use with an endosseous implant for temporary use during soft tissue healing after one-stage or two-stage surgeries. The Atlantis Abutment screw is intended to secure the Atlantis Healing Abutment to the endosseous implant.

    Implant Manufacturer: Institut Straumann
    Implant System: Straumann BLX
    Implant Diameter (in mm): 3.5, 3.75, 4.0, 4.5, 5.0, 5.5, 6.5
    Abutment Platform Diameter (in mm): 2.69

    Implant System: Neodent GM
    Implant Diameter (in mm): 3.5, 3.75, 4.0, 4.3, 5.0, 6.0, 7.0
    Abutment Platform Diameter (in mm): 3.0

    Device Description

    The Atlantis® Abutments in Titanium are patient-specific dental abutments that are intended for attachment to dental implants in the treatment of partially or totally edentulous jaws for the purpose of restoring chewing function. The design of the Atlantis® Abutments in Titanium is derived from patient dental models and is completed by Dentsply Sirona using computer-assisted design (CAD) technology according to the clinician's prescription. The final CAD design of the Atlantis® Abutment in Titanium is fabricated using computer-assisted manufacturing (CAM) to produce a customized, patient-specific device. Design and fabrication of the Atlantis® Abutment in Titanium is completed in internal Dentsply Sirona manufacturing facilities.

    Alternatively, the CAD design, according to the clinician's prescription, can be performed by a laboratory or clinician in an FDA cleared abutment design software (3Shape Abutment Designer Software, K151455) within the design envelope of the Atlantis® Abutments which is codified in the validated and locked design library of the cleared software. Fabrication of the Atlantis® Abutment is then completed in internal Dentsply Sirona manufacturing facilities.

    The Atlantis® Abutment in Titanium serves as a connection of the prosthetic construction and the endosseous implant. The lower part of the abutment is designed to fit with the specific implant geometry it is compatible, and the upper part design is according to the patient's specific anatomy. The Atlantis® Abutment, including the Conus and Healing abutments further described below, are available in Titanium or Gold-shaded (titanium nitride layer applied using PVD (Physical Vapor Deposition)) Titanium. The Crown Abutment which is another Atlantis® Abutment in Titanium, is only available in Titanium.

    The Atlantis® Abutment design envelope became the basis for the other more specific designs that make up the Atlantis® Abutments in Titanium. The Atlantis® Abutment is intended for use with an endosseous implant and for single tooth restoration.

    The Atlantis® Crown Abutment in Titanium is also a custom fabricated abutment using the same internal CAD/CAM technology. The Atlantis® Crown Abutment in Titanium incorporates a design that is a combination of an abutment and an anatomically accurate crown to constitute the final finished device. It functions as a substructure that also serves as the final abutment, in a partially or completely edentulous patient.

    The Atlantis® Conus Abutment supports a removable prosthesis (bridges and overdentures) which is retained by friction fit to the abutment. The abutment connects to the prosthesis via caps embedded in the prosthesis.

    The Atlantis® Healing Abutment is used with the compatible implants for temporary use during soft tissue healing after one-stage and two-stage surgeries. It is designed based on the planned final Atlantis® Abutment or Atlantis® Crown Abutment, using the same emergence profile as those abutments to achieve an aesthetic outcome during the soft tissue healing phase.

    The proposed Atlantis® Abutments in Titanium for Straumann BLX Implant are compatible with the Straumann BLX Implants. This implant system is available in diameters of 3.5, 3.75, 4.0, 4.5 5.0, 5.5 and 6.5 mm and in lengths of 8, 10, 12, 14, 16, and 18 mm all with identical mating geometry.

    The proposed Atlantis® Abutments in Titanium for Neodent GM Implant are compatible with the Neodent GM Implants. This implant system is available in diameters of 3.5, 3.75, 4.0, 4.3, 5.0, 6.0, and 7.0 mm and in lengths of 7, 8, 9, 10, 11, 11.5, 13, 15, 16, 17 and 18 mm, all with identical mating geometry.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250771

    Validate with FDA (Live)

    Device Name
    Primescan 2
    Date Cleared
    2025-08-29

    (169 days)

    Product Code
    Regulation Number
    872.1745
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Primescan 2 can be used as a diagnostic aid by licensed dentists for detection of caries on visible tooth surfaces, proximal caries, and tooth cracks.

    Device Description

    The Primescan 2 is an intraoral scanner that records and generates digital images to provide caries diagnosis support using additional light sources at 405 nm and 850 nm and an optical filter to filter out the excitation light. By illuminating the tooth with these two wavelengths, two diagnosis support modes are realized, the fluorescence mode and the near-infrared mode. The acquired 2D data from the scanner can be viewed in the software in a live stream video during acquisition. The images are also stored in the cloud platform software for later patient communication.

    In fluorescence mode, the tooth (or teeth) are illuminated with UV light (405 nm). This stimulates an autofluorescence of the enamel in the green wavelength range. In addition, the red fluorescence is stimulated in carious areas on the teeth. All stimulated fluorescence responses are significantly weaker in terms of their light intensity compared to the back-reflected excitation light. For this reason, the excitation light is filtered out with the aid of an optical filter. The dental professional can use the 2D image data of the fluorescence response (live stream video) as additional information for caries diagnosis.

    For near-infrared mode (NIR mode), the tooth or teeth are illuminated with 850 nm. Enamel is partially transparent in this wavelength. The illumination can therefore penetrate the tooth and is reflected by structural defects such as cracks and cavities, as well as from the dentin core. The reflected light is picked up by the 2D sensor of the scanner.

    When used, a sleeve is placed over the distal end of the scanner. This sleeve is the only patient contacting component and is offered as either a single-use disposable or a multi-use sleeve that is reprocessed.

    AI/ML Overview

    Here's the breakdown of the acceptance criteria and study information for the Primescan 2 device, based on the provided FDA 510(k) clearance letter:


    Acceptance Criteria and Device Performance

    The provided document does not explicitly state quantitative acceptance criteria or a specific table outlining them. However, it does mention that "in vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid for occlusal caries using the fluorescence function and tooth cracks using the NIR function." This implies that the device met an unstated level of effectiveness for these diagnostic aids.

    Since specific quantitative metrics (e.g., sensitivity, specificity, accuracy) are not provided in the summary, we cannot populate a detailed table with numerical acceptance criteria and performance outcomes.

    Acceptance CriterionReported Device Performance
    Effectiveness as diagnostic aid for occlusal caries (fluorescence mode)Demonstrated effectiveness
    Effectiveness as diagnostic aid for tooth cracks (NIR mode)Demonstrated effectiveness

    Study Details

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified in the provided document.
    • Data Provenance: The study was "in vivo bench tests," implying data was collected from living subjects. The country of origin and whether it was retrospective or prospective is not explicitly stated.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not specified.
    • Qualifications of Experts: Not specified.

    4. Adjudication method for the test set

    • Adjudication Method: Not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: Not mentioned in the provided document. The study described is "Performance Validation Testing of the Caries diagnostic Aid - In vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid..." This describes standalone device performance rather than human-in-the-loop improvement.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • Standalone Performance Study: Yes, a standalone performance study was done. The document states: "Performance Validation Testing of the Caries diagnostic Aid - In vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid for occlusal caries using the fluorescence function and tooth cracks using the NIR function." This indicates the device's ability to provide a diagnostic aid on its own.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Type of Ground Truth: Not explicitly stated. For "in vivo bench tests" related to caries and tooth cracks, ground truth would typically be established through a combination of visual-tactile examination by experienced clinicians, potentially supplemented by radiography or even histology (though less common for a diagnostic aid). However, the document does not specify the method used here.

    8. The sample size for the training set

    • Sample Size for Training Set: Not applicable or not specified. This device appears to be a direct imaging and diagnostic aid rather than an AI/ML algorithm that requires a separate training set. The "diagnostic support" refers to the illumination and optical filtering techniques, not necessarily an AI algorithm trained on a dataset.

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set: Not applicable, as there's no indication of an AI/ML algorithm with a training set. The device operates on optical principles.

    Key Observations and Limitations of Information:

    • The provided 510(k) summary focuses highly on technological comparisons, safety, and regulatory compliance (electrical safety, biocompatibility, reprocessing, software, cybersecurity).
    • While it mentions "Performance Validation Testing," it lacks specific quantitative results (e.g., sensitivity, specificity, accuracy, AUC) that are typically associated with diagnostic device clearances.
    • The clinical study details, such as sample size, expert qualifications, and ground truth establishment methods for the performance validation, are not provided in this specific document. This information would typically be in a more detailed study report submitted to the FDA, but is summarized very broadly here.
    • The device is described as providing "diagnostic support" using optical modes (fluorescence and NIR), rather than an explicit AI algorithm.
    Ask a Question

    Ask a specific question about this device

    K Number
    K251811

    Validate with FDA (Live)

    Date Cleared
    2025-08-25

    (74 days)

    Product Code
    Regulation Number
    872.4200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Midwest Motor Control Module includes a control unit, ports for three motors, an apex location port, and a peristaltic pump port. The motor ports are compatible with the Midwest Power Lux and Midwest Power Lux Implant.

    The Midwest Power Lux electric micromotor is intended for use as a drive for rotating and oscillating straight and contra-angle hand pieces for endodontic and general dental purposes.

    The Midwest Power Lux Implant motor is intended for use in implant placement and includes a closed system for delivery of sterile solution via peristaltic pump operation.

    The apex locator supports the dentist in the determination of the working length during the endodontic treatment.

    These motors are to be driven by the control unit. The control unit is an internal component of a dental delivery system.

    The use of this product is intended exclusively for duly qualified dental practitioners.

    Device Description

    This device is a system that includes a control module (internal component of a dental delivery system) that can operate up to three dental motors, an apex locator, and a peristaltic pump. The motors do not operate concurrently. The motors that can be attached include dental motors and dental implant motors. The motors included with this module in this subject system are the Midwest Power Lux and Midwest Power Lux Implant. Also included is the cable, file, and tip required for the operation of the apex location technology. The programming supports manual use of the apex locator as well as combined use of the locator with a motor. The included peristaltic pump and control allows for sterile solution irrigation when required.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the "Motor and Apex Module (MaAM)" (K251811) does not contain information about acceptance criteria or a study that proves the device meets specific performance criteria related to the apex locator's accuracy or the motors' performance in a clinical setting.

    The document primarily focuses on regulatory approval, substantial equivalence to predicate devices, and general safety and performance testing. While it mentions the device supports "determination of the working length during the endodontic treatment" (for the apex locator) and drives "rotating and oscillating straight and contra-angle hand pieces for endodontic and general dental purposes" (for the motors), it does not provide the specific performance metrics (e.g., accuracy, precision, torque output, speed stability) for these functions, nor the studies that verified them.

    The "Non-Clinical and/or Clinical Tests Summary & Conclusions" section explicitly states: "Not applicable (no clinical data necessary)." This indicates that the FDA clearance was based on non-clinical testing, primarily focused on safety, electrical compatibility, and adherence to established industry standards (ISO 14457 for dental motors, IEC 62471 for photobiological safety, and ISO 3964 for dental coupling dimensions).

    Therefore, based solely on the provided document, I cannot generate the requested table and study details. The information about performance acceptance criteria, sample sizes, expert involvement, adjudication, MRMC studies, standalone performance, and ground truth establishment for clinical effectiveness is absent.

    However, I can extract and present the information that is available in the document regarding testing:


    Summary of Device Performance and Testing (Based on Available Information in K251811)

    The provided 510(k) clearance letter for the Motor and Apex Module (MaAM) establishes substantial equivalence to predicate devices based on non-clinical testing. The document explicitly states "Not applicable (no clinical data necessary)", indicating that the clearance did not involve clinical studies assessing the device's functional performance in a patient setting, such as the accuracy of the apex locator or the clinical efficacy of the motors.

    The testing highlighted in the document focuses on compliance with international standards and mechanical/electrical safety.

    1. Table of Acceptance Criteria and Reported Device Performance

    Given that clinical performance acceptance criteria and respective reported device performance data are not detailed in the provided document, the table below reflects the types of non-clinical testing mentioned and the general conclusion of meeting specifications.

    Acceptance Criterion (Type of Testing)Reported Device Performance
    Dental Motors (ISO 14457)Device met specifications in accordance with ISO 14457 for dental motors. (Specific metrics not provided)
    Photobiological Safety (IEC 62471)Device met specifications in accordance with IEC 62471:2006 for photobiological safety of lamps and lamp systems.
    Dental Coupling Dimensions (ISO 3964)Device met specifications in accordance with ISO 3964:2018 AMD1:2018 for dental coupling dimensions.
    Electrical Safety / EMC(Implicitly part of regulatory requirements; specific standards/results not detailed but assumed to be met for clearance).
    Mechanical Integrity(Implicitly part of regulatory requirements; specific tests/results not detailed but assumed to be met for clearance).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not specified in the document. Testing was non-clinical (bench/laboratory).
    • Data Provenance: Non-clinical (bench testing in a laboratory). Country of origin is not specified for the test data itself, but the applicant (Dentsply Sirona Inc.) is located in the United States. The testing was retrospective in the sense that it was conducted prior to the submission for clearance.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • Not applicable. The clearance was based on non-clinical, standard-driven testing. There was no clinical ground truth established by experts for performance assessment in a patient setting.

    4. Adjudication Method for the Test Set

    • Not applicable. No clinical test set or subjective assessment requiring adjudication (like image interpretation) was mentioned.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No MRMC study was done. The document explicitly states "Not applicable (no clinical data necessary)". Therefore, no effect size of human readers improving with AI vs. without AI assistance can be reported. The device is not an AI-assisted diagnostic tool in the sense of image interpretation.

    6. Standalone Performance (Algorithm Only)

    • Not applicable. The device is a physical medical device (motors, control module, apex locator) and not an algorithm or AI software for standalone performance evaluation in a diagnostic context. Its "performance" refers to its physical and electrical operation within specified limits, not its diagnostic accuracy.

    7. Type of Ground Truth Used

    • Not applicable, for clinical performance. For the non-clinical tests, the "ground truth" was established by the specifications defined in the referenced ISO and IEC standards (e.g., a motor must achieve a certain speed, a coupling must fit, light emission must be within safety limits). There was no "expert consensus, pathology, or outcomes data" ground truth as would be used for diagnostic accuracy studies.

    8. Sample Size for the Training Set

    • Not applicable. This device is hardware with embedded control software; it is not a machine learning or AI model that requires a training set in the typical sense of algorithm training on data.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As above, this device does not utilize a "training set" in a machine learning context.

    In conclusion, the FDA 510(k) clearance for the MaAM (K251811) was granted based on non-clinical testing demonstrating conformance to relevant safety and performance standards for dental motors, photobiological safety, and dental coupling dimensions. The document explicitly states that no clinical data was necessary for this clearance, meaning functional performance (e.g., apex locator accuracy, motor clinical efficacy) in a patient setting was not assessed as part of this submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251647

    Validate with FDA (Live)

    Date Cleared
    2025-08-21

    (84 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MIS dental implant system is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore masticatory function. When a one-stage surgical procedure is applied, the implant may be immediately loaded when good primary stability is achieved and the occlusal load is appropriate.

    Narrow implants (Ø3.30mm) are indicated for use in surgical and restorative applications for placement only in the mandibular central, lateral incisor and maxillary lateral incisor regions of partially edentulous jaws, to provide support for prosthetic devices such as artificial teeth. Mandibular central and lateral incisors must be splinted if using two or more narrow implants adjacent to one another.

    Device Description

    The subject devices, MIS Implants, are supplied sterile and packaged together with a cover screw which can be connected to the implant during the initial healing period after implant placement.

    The implants and cover screws are made of titanium alloy (Ti-6Al-4V ELI complying with standard ASTM F136-13 - Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant). The design and material of the implants and cover screws remain unchanged since most recently cleared 510(k).

    The implants are also used with a wide range of previously cleared abutments which are sold separately.

    AI/ML Overview

    This document is a 510(k) clearance letter for dental implants, not an AI/software as a medical device (SaMD) submission. Therefore, it does not contain the information requested regarding acceptance criteria and study proving device meets acceptance criteria for an AI/SaMD product.

    The document discusses dental implants and their physical and material characteristics, regulatory classifications, predicate devices, and performance testing for mechanical properties, sterility, and packaging. The "Performance Data" section specifically mentions "Hydrophilicity testing" for "wet-packed implants" and other physical tests, but none of these relate to AI/SaMD performance metrics like sensitivity, specificity, or reader studies.

    Therefore, I cannot provide a table of acceptance criteria, sample sizes for test sets, expert qualifications, or details on MRMC studies, standalone performance, or ground truth establishment relevant to an AI/SaMD product based on the provided text.

    The prompt asks for information that this type of medical device submission (dental implants) would not typically include.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250755

    Validate with FDA (Live)

    Date Cleared
    2025-08-12

    (153 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DS Core Diagnosis is a software product for use in dentistry for viewing and interacting with digital or digitized patient media as well as supporting the diagnosis of digital or digitized patient media. Intended users will be able to view and analyze different media types in one viewer.

    The Panoramic Curve Proposal feature is intended for patients aged 12 years and older with permanent dentition.

    Device Description

    DS Core Diagnosis is a cloud-based dental imaging software that provides access to dental media and images via an active internet connection. It is a medical device that can only be used in combination with the DS Core Platform. Classified as a Class II dental imaging software, DS Core Diagnosis allows users to view a variety of media types, including 2D and 3D images (e.g., bitewings, periapicals, panoramic, CBCT, etc.), as well as photos and documentation.

    The software includes standard image viewing tools such as annotation, flip, rotate, contrast adjustment, brightness, and magnification.

    DS Core Diagnosis also features a Machine Learning enabled panoramic curve proposal algorithm for a proposed panoramic curve of a CBCT scan along the dental arch, which can be adjusted and reviewed by the user. The architecture is a Convolutional Neural Network (CNN) model.

    DS Core Diagnosis does not interact directly with patients or control any life-sustaining devices. The software does not perform diagnoses; instead, it provides tools to assist qualified clinicians in interpreting the displayed images and making informed decisions.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and the study proving the device meets them, based on the provided FDA 510(k) clearance letter for DS Core Diagnosis:

    Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Panoramic Curve Proposal Success Rate (PCPSR): Percentage of cases where the proposed panoramic curve projection layer includes all teeth in the scan.Dentsply Sirona Scans: PCPSR of 98.81%, with the lower bound of the 95% CI at 94.57%.All Scans (Dentsply Sirona & Third Party): PCPSR of 99%, with 99 of 100 scans considered "successful" and the lower bound of the 95% CI at 95.42%.Various Subgroups: PCPSR range of 97.78-100%, all passing the acceptance criteria.
    Clinical Acceptability (Pass/Fail) of Default Panoramic Image: Determine the acceptability of the CBCT reconstructed panoramic images (without user modification) with the panoramic curve proposal generated by the PCP algorithm, to begin working per the standard of care.Clinical Evaluation Pass Rate: 92.5% pass rate overall for the primary endpoint.
    System validation and usability testing for the DS Core Diagnosis device.All tests successfully passed.

    Study Details

    Based on the provided text, the following details about the studies can be extracted:

    2. Sample size used for the test set and the data provenance:

    • PCPSR Evaluation:
      • Test Set Size (Dentsply Sirona & Third Party): 100 scans (specifically mentioned "99 of 100 scans considered 'successful'").
      • Data Provenance: A mix of "Dentsply Sirona Scans" and "Third Party" scans. Specific countries of origin are not detailed, but the inclusion of third-party scans suggests a broader dataset. The text does not explicitly state if it was retrospective or prospective, but given the nature of evaluating existing scans, it's highly likely to be retrospective.
    • Clinical Evaluation:
      • Test Set Size: "a dataset made up of CBCT images". The exact number of cases or images in this dataset is not explicitly stated.
      • Data Provenance: Not explicitly stated, but would likely be retrospective CBCT images used for evaluation.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • PCPSR Evaluation: The text doesn't explicitly state that experts established ground truth for the PCPSR calculation directly. The success rate is described as whether "the proposed panoramic curve projection layer includes all teeth in the scan," which likely refers to an objective assessment based on the image content itself, possibly verified by a technical process rather than subjective expert consensus.
    • Clinical Evaluation: "clinical experts assessed a dataset". The number of experts is not specified. Their qualifications are described as "clinical experts," implying dental professionals (e.g., dentists, oral and maxillofacial radiologists) but their specific experience levels (e.g., "radiologist with 10 years of experience") are not detailed.

    4. Adjudication method for the test set:

    • The text does not explicitly mention an adjudication method (like 2+1, 3+1). For the clinical evaluation, it states "experts assessed," which could imply independent assessment or consensus, but no specific method is described. For the PCPSR evaluation, the metric seems more objective and less prone to requiring adjudication in the same way.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC comparative effectiveness study where human readers' performance with and without AI assistance is compared is not explicitly described. The clinical evaluation focuses on the acceptability of the default AI-generated curve, not a comparison of expert performance with and without AI. It emphasizes that users retain full autonomy to adjust the curve.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Yes, a standalone performance evaluation was done for the "Panoramic Curve Proposal" feature. The PCPSR evaluation directly assesses the algorithm's ability to propose a curve that includes all teeth, without human intervention in the proposal generation or acceptance. The "clinical evaluation" also assesses the default AI-generated panoramic image "without user modification."

    7. The type of ground truth used:

    • PCPSR Evaluation: The ground truth appears to be an objective determination of whether "all teeth in the scan" are included within the proposed panoramic curve. This would likely be established by a clear definition and potentially manual verification of tooth inclusion. It is closer to expert consensus if human verification was involved, but the description sounds more like an objective technical check.
    • Clinical Evaluation: The ground truth for this aspect was established by expert consensus/assessment from "clinical experts" on the "clinical acceptability" (pass/fail) of the reconstructed panoramic images.

    8. The sample size for the training set:

    • The document does not provide any information about the sample size used for the training set for the Convolutional Neural Network (CNN) model.

    9. How the ground truth for the training set was established:

    • The document does not provide any information about how the ground truth for the training set was established. It only describes that the architecture is a Convolutional Neural Network (CNN) model.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 9