510(k) Data Aggregation

    K Number
    K111689

    Validate with FDA (Live)

    Device Name
    STLASE
    Date Cleared
    2012-02-16

    (245 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The stLase with surgical laser operation (Automatic Power Control) that can be used in contact or non-contact technique, is indicated for dental soft tissue indications including: incision, excision, vaporization, ablation, hemostasis, or coagulation of intraoral and extraoral soft tissue (including marginal and interdental gingiva and epithelial lining of free gingiva). Examples include: frenectomy, frenotomy, biopsy, operculectomy, implant recovery/uncovery, gingivectomy, gingivoplasty, gingival troughing, crown lengthening, removal of granulation tissue, laser assisted flap surgery, debridement of diseased epithelial lining, incisions and draining of abscesses, tissue retraction for impressions, papillectomy, vestibuloplasy, excision of lesions, exposure of unerupted/partially erupted teeth, leukoplakia, removal of hyperplastic tissues, and sulcular debridement (removal of diseased or inflamed soft tissue in the periodontal pocket).

    The stLase with surgical laser operation that can be used in contact or non-contact technique is intended for use in general surgery for incision/excision, vaporization, ablation and coagulation of soft tissue, and

    The stLase with dental laser operation is intended to be used in contact or non-contact technique for incision, excision, vaporization, ablation, hemostasis, or coagulation of intraoral and extraoral soft tissue (including marginal and interdental gingiva and epithelial lining of free gingiva). Examples include: frenectomy, frenotomy, biopsy, operculectomy, implant recovery/uncovery, gingivectomy, gingivoplasty, gingival troughing, crown lengthening, hemostasis of donor site, removal of granulation tissue, laser assisted flap surgery, debridement of diseased epithelial lining, incisions and draining of abscesses, tissue retraction for impressions, papillectomy, vestibuloplasty, excision of lesions, exposure of unerupted/partially erupted teeth, leukoplakia, removal of hyperplastic tissues, treatment of aphthous ulcers, sulcular debridement (removal of diseased or inflamed soft tissue in the periodontal pocket), pulpotomy, pulpotomy as an adjunct to root canal therapy, and light activation of bleaching materials for teeth whitening.

    Device Description

    The Dental Photonics stLase is a soft tissue surgical laser system indicated for use in dental applications. It can generate up to 25 W at 980 nm wavelength in fiberoptic output used for a variety of dental and oral surgical applications, including cutting and coagulation of intraoral and extraoral soft tissues.

    AI/ML Overview

    This document is a 510(k) Summary of Safety and Effectiveness for the Dental Photonics stLase, a soft tissue surgical laser system. It describes the device, its intended use, and argues for its substantial equivalence to a predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not specify formal acceptance criteria in terms of performance metrics (e.g., accuracy, sensitivity, specificity) for the device's function. Instead, the "acceptance criteria" presented here is based on demonstration of substantial equivalence to a predicate device. The performance is reported by showing that the technical specifications of the current device are identical to the predicate device.

    SpecificationAcceptance Criteria (Predicate Device K094049)Reported Device Performance (stLase K111689)Meets Criteria?
    Wavelength980 nm980 nmYes
    Output power25 W25 WYes
    Power range0.5-25 W0.5-25 WYes
    Increments0.1-0.5 W0.1-0.5 WYes
    Operating modesPulsed or CWPulsed or CWYes
    Pulse duration0.025 ms to 3 ms0.025 ms to 3 msYes
    Timer duration50 ms to 99.9 s50 ms to 99.9 sYes
    Frequency20,000 Hz20,000 HzYes
    Aiming beam650 nm, 5mW650 nm, 5mWYes
    CoolingAir cooled, closed control water circuitAir cooled, closed control water circuitYes
    Weight~ 1.8 kg (4 lbs)~ 1.8 kg (4 lbs)Yes
    Dimensions14"x14.2"x11"14"x14.2"x11"Yes
    Power requirements120V/60Hz or 240V/50Hz120V/60Hz or 240V/50HzYes
    Sterilization methodSteam autoclaveSteam autoclaveYes

    The study that proves the device meets "acceptance criteria" (in this context, substantial equivalence) is the technical comparison and bench testing to demonstrate that the new stLase (K111689) has the "same material design, mechanism of action, technical specifications and function" as the predicate device (stLase K094049).

    2. Sample Size Used for the Test Set and Data Provenance:

    The document exclusively relies on a comparison of technical specifications and bench testing. There is no test set of patient data, clinical data, or imaging data mentioned for evaluating the device's performance in terms of diagnostic or therapeutic outcomes. The provenance of the data is a comparison of published specifications of two laser devices, presumably from internal company documentation and previous 510(k) submissions. This is not retrospective or prospective patient data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications:

    Not applicable. There is no test set with patient data requiring expert-established ground truth. The "ground truth" for the technical specifications are the validated specifications of the predicate device, which would have been established through engineering and performance testing at the time of its initial clearance (K094049).

    4. Adjudication Method for the Test Set:

    Not applicable, as there is no test set of patient data.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. This device is a surgical laser, not a diagnostic imaging device typically evaluated with MRMC studies comparing human readers with and without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    Not applicable. This device is not an AI algorithm. It is a surgical laser that requires human operation. The performance assessment is based on its physical characteristics and functionality, not an AI algorithm's standalone performance.

    7. The Type of Ground Truth Used:

    The "ground truth" used for demonstrating substantial equivalence is the technical specifications and established performance characteristics of the predicate device (K094049) as determined by engineering validation and previous regulatory clearance. This is not pathology, outcomes data, or expert consensus on clinical cases.

    8. The Sample Size for the Training Set:

    Not applicable. This device does not involve a training set as it is not an AI/machine learning device.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable, as there is no training set for an AI/machine learning algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K094049

    Validate with FDA (Live)

    Date Cleared
    2010-09-10

    (253 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The stLase™ with surgical laser operation that can be used in contact or noncontact technique is intended for use in general surgery for incision/excision, vaporization, ablation and coagulation of soft tissue, and The stLase™ with dental laser operation that can be used in contact or non-contact technique is intended for incision, excision, vaporization, ablation, hemostasis, or coagulation of intraoral and extraoral soft tissue (including marginal and interdental gingiva and epithelial lining of free gingiva). Examples include: frenectomy, frenotomy, biopsy, operculectomy, implant recovery, gingivectomy, gingivoplasty, gingival troughing, crown lengthening, hemostasis of donor site, removal of granulation tissue, laser assisted flap surgery, debridement of diseased epithelial lining, incisions and draining of abscesses, tissue retraction for impressions, papillectomy, vestibuloplasy, excision of lesions, exposure of unerupted/partially erupted teeth, leukoplakia, removal of hyperplastic tissues, treatment of aphthous ulcers, sulcular debridement (removal of diseased or inflamed soft tissue in the periodontal pocket), pulpotomy, pulpotomy as an adjunct to root canal therapy, and light activation of bleaching materials for teeth whitening.

    Device Description

    The Dental Photonics stLase™ is a 980 nm wavelength diode laser intended for use in general surgical applications and dental laser applications.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study information for the stLase™ device:

    1. Table of Acceptance Criteria and Reported Device Performance

    Based on the provided 510(k) summary, there are no specific, quantitative acceptance criteria or corresponding reported device performance metrics like sensitivity, specificity, accuracy, or other statistical measures typically found for diagnostic or predictive AI devices.

    Instead, the device's acceptance is based on:

    Acceptance Criteria TypeReported Device Performance (as stated in the document)
    Substantial Equivalence to Predicate Devices"Substantial equivalence of the stLase™ is demonstrated by similarity in technical specifications to the predicate devices.""The stLase™ has the same intended use, material design and function as predicate devices for dental laser applications: Biolitec Ceralas D980 family of lasers K081015; the Kavo GentleRay 980, K072262; and the same intended use, material design and function as the predicate device for general surgery laser applications: Dornier Medilas D family of lasers, K982629."
    Compliance with Regulatory Standards (Laser Safety)"As a laser device, the stLase™ complies with 21 CFR 1040.10 and 1040.11 and other applicable laser and electrical safety standards."
    Intended Use AlignmentThe stated intended uses for general surgery and dental applications (listed extensively) are deemed equivalent to those of the predicate devices.
    Device Description AlignmentThe device's description as a "980 nm wavelength diode laser intended for use in general surgical applications and dental laser applications" is deemed similar to predicate devices.

    Explanation of Device Type: This device is a surgical laser, not an AI/ML-driven diagnostic or predictive tool. Therefore, the "acceptance criteria" and "study" are not based on performance metrics like AUC, sensitivity, or specificity relative to a ground truth established by experts. Instead, the acceptance is based on demonstrating substantial equivalence to previously cleared predicate devices through shared technical specifications, intended uses, and compliance with general safety and performance standards for laser devices.

    2. Sample size used for the test set and the data provenance

    Not applicable. The document describes a direct comparison and substantial equivalence to predicate devices rather than performance testing on a specific data set. There is no "test set" in the context of AI/ML performance evaluation.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. There is no "test set" or ground truth established by experts in the context of AI/ML performance evaluation for this device. The evaluation focuses on technical specifications and functional equivalence to predicate devices, and compliance with general laser safety standards.

    4. Adjudication method for the test set

    Not applicable. No test set or expert adjudication process is described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a surgical laser device, not an AI-assisted diagnostic tool. No MRMC study or AI assistance is mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device (a surgical laser), not a standalone algorithm. Its operation inherently involves a human operator.

    7. The type of ground truth used

    Not applicable in the context of AI/ML performance. The "truth" for this device's clearance is its compliance with regulatory standards (e.g., laser safety, electrical safety) and its demonstrated functional and intended use equivalence to legally marketed predicate devices. This is a regulatory "ground truth" rather than a clinical ground truth established for an AI model.

    8. The sample size for the training set

    Not applicable. There is no AI/ML training set mentioned or implied.

    9. How the ground truth for the training set was established

    Not applicable. There is no AI/ML training set.

    Ask a Question

    Ask a specific question about this device