Found 9 results

510(k) Data Aggregation

    K Number
    K250889

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-04-17

    (23 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EXULT Knee Replacement System is indicated for the treatment of diseases as follows:

    • Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis or avascular necrosis) or rheumatoid arthritis;
    • Post-traumatic loss of knee joint configuration and function;
    • Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability;
    • Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure.

    The EXULT Knee Replacement System is intended for cemented use only.

    Device Description

    The purpose of this submission is to introduce EXULT Tibial Insert UCR (Ultra Congruent & Cruciate Retaining) which is a line extension to the EXULT Knee Replacement System.

    The EXULT Tibial Insert UCR is a modification to the PCL (Posterior Cruciate Ligament) notch of the EXULT Tibial Insert UC (K242046). This change allows the EXULT Tibial Insert UC to be used by surgeons who do not resect the PCL when implanting an EXULT Tibial Insert UC. Tibial Insert is used at both right and left knee. It is only used in combination with the same Femoral component and Tibial baseplate of the predicate device.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the EXULT Knee Replacement System (K250889) does not contain any information about an AI/ML-driven medical device, nor does it include details about a study that assesses AI/ML performance against acceptance criteria.

    This document pertains to a medical device (a knee replacement system) that is a physical implant made of materials like UHMWPE. The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to engineering and biomechanical tests to ensure the mechanical integrity, wear characteristics, range of motion, and other physical properties of the knee implant.

    Therefore, I cannot fulfill your request to describe the acceptance criteria and study for an AI/ML device based on this input. The provided text does not contain any of the required information regarding AI/ML performance, sample sizes for AI/ML test sets, expert ground truth adjudication, MRMC studies, standalone AI performance, or training set details.

    The "Non-Clinical Testing" section on Page 7 lists the following mechanical/physical tests:

    • Contact area/pressure per ASTM F2083
    • Interlocking test per ASTM F1814
    • Wear of articular surface per ISO 14243-2/3
    • Range of Motion analysis per ISO 21536
    • Constraint analysis per ASTM F1223
    • Endurance and deformation under high flexion per ASTM F2777

    These are standard tests for orthopedic implants and are not related to AI/ML performance. The "Clinical Testing" section explicitly states: "Clinical data was not needed to support the safety and effectiveness of the subject device." This further confirms that no clinical study involving human readers or AI assistance was conducted for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242401

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-09-12

    (30 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EXULT Knee Replacement System is intended for the treatment of diseases as follows:

    • Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis or avascular necrosis) or rheumatoid arthritis.
    • Post-traumatic loss of knee joint configuration and function.
    • . Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability.
    • . Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure

    EXULT Knee Replacement System is intended for cemented application only.

    Device Description

    The purpose of the submission is a line extension of the EXULT Tibial Insert (CPS-type) to the EXULT Knee Replacement System (K192507). The CPS-type Tibial Inserts are designed based on the design of the other previously cleared Tibial Inserts of the EXULT Knee Replacement System (PS-type, CR-type and UC-type). The CPS-type, which is constrained posterior stabilized, has a thicker and wider post which provides additional constraint as compared to the PS-type insert. The CPS-type Tibial Insert matches with Femoral Components of one-size up and down. The CPS-type Tibial Insert is symmetrical and used in both the right and left knee. It is only used in combination with the Femoral component/Tibial baseplate of the predicate device (K192507).

    AI/ML Overview

    The provided text does not contain information about acceptance criteria and a study that proves a device meets those criteria for software or AI/ML-driven medical device performance.

    The document is a 510(k) premarket notification for the EXULT Knee Replacement System, a physical orthopedic device. It discusses the device's indications for use, technological characteristics, and non-clinical testing performed to establish substantial equivalence to predicate devices (other knee replacement systems).

    The "Non-Clinical Testing" section lists various engineering tests (wear testing, fatigue testing, constraint testing, range of motion, surface roughness, disassembly) and references ISO and ASTM standards. These are traditional mechanical engineering tests for orthopedic implants, not performance studies for AI/ML algorithms.

    Therefore, I cannot provide the requested information regarding:

    • A table of acceptance criteria and reported device performance (for AI/ML).
    • Sample size for the test set and data provenance.
    • Number and qualifications of experts for ground truth.
    • Adjudication method.
    • MRMC comparative effectiveness study.
    • Standalone performance study.
    • Type of ground truth used.
    • Sample size for the training set.
    • How ground truth for the training set was established.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242046

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-08-01

    (20 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EXULT Knee Replacement System is indicated for the treatment of diseases as follows:

    · Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis traumatic arthritis or avascular necrosis) or rheumatoid arthritis.

    · Post-traumatic loss of knee joint configuration and function.

    • Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability.

    · Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure.

    EXULT Knee Replacement System is intended for cemented application only.

    Device Description

    The purpose of the submission is a line extension of the EXULT Tibial Insert (UC-type) to the EXULT Knee Replacement System (K192507). The UC-type Tibial Inserts are designed based on the design of the other Tibial Inserts of the EXULT Knee Replacement System (PS-type and CR-type). The UC-type, which is ultra-congruent, has high conformity and increased anterior/posterior edge height, which limits anterior/posterior motion instead of a post structure, like the PS-type. The UC-type Tibial Insert matches Femoral Components of one-size up and down. The UC-type Tibial Insert is symmetrical and used in both the right and left knee. It is only used in combination with the Femoral component/Tibial baseplate of the predicate device (K192507).

    AI/ML Overview

    Here's an analysis of the provided text regarding acceptance criteria and study information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Wear Testing as per ISO 14242-1&2, ASTM F2003-02Evaluated to demonstrate substantial equivalence to predicate devices.
    Constraint test as per ASTM F1223Evaluated to demonstrate substantial equivalence to predicate devices.
    Contact pressure as per ASTM F2083, ASTM F1672Evaluated to demonstrate substantial equivalence to predicate devices.
    Range of Motion as per ISO 21536Evaluated to demonstrate substantial equivalence to predicate devices.

    Important Note: The document does not provide specific numerical acceptance criteria or numerical reported device performance values for any of these tests. It only states that the device was "evaluated to demonstrate substantial equivalence to the predicate devices" based on these tests.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided in the document. The text mentions "non-clinical testing" but does not specify sample sizes for materials tested, nor does it refer to patient data (retrospective or prospective) or countries of origin.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    This information is not applicable and therefore not provided in the document. The device is a knee replacement system (implant), not an AI/software device that requires expert-established ground truth for image interpretation or diagnosis. The tests described are mechanical and material performance tests.

    4. Adjudication Method for the Test Set

    This information is not applicable and therefore not provided in the document. As noted above, this is a mechanical device, not an AI/software device involving human reader interpretation.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    This information is not applicable and therefore not provided in the document. This is a medical device (knee implant), not an AI-assisted diagnostic or treatment planning software.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This information is not applicable and therefore not provided in the document. This is a medical device (knee implant), not an AI algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the non-clinical testing of this knee implant system would be the physical and mechanical properties of the device and its predicate, measured according to established international and ASTM standards. For instance, in wear testing, the "ground truth" is the actual material loss measured. In contact pressure testing, it's the measured pressure distribution.

    8. The Sample Size for the Training Set

    This information is not applicable and therefore not provided in the document. This is a medical device (knee implant), not a machine learning model that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable and therefore not provided in the document. As this is not an AI/ML device, there is no training set or ground truth in that context.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223828

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-03-16

    (85 days)

    Product Code
    Regulation Number
    888.3353
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BENCOX Delta Option Heads of BENCOX Total Hip System is intended for Cementless use in total or partial hip arthroplasty in primary or revision surgery for the following conditions:

    a. Non-inflammatory degenerative joint disease, such as avascular necrosis, osteoarthritis, traumatic arthritis

    b. Inflammatory degenerative joint disease, such as rheumatoid arthritis

    c. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement. unmanageable using other techniques

    d. Patients with failed previous surgery where pain, deformity, or dysfunction persists

    e. Revision of previously failed total hip arthroplasty

    Device Description

    The BENCOX Delta Option Head consists of a delta ball head and a titanium sleeve (Ti6Al4V). The ball heads are made of the BIOLOX® delta ceramic material, which is a high-purity alumina composite material according to ISO 6474-2 Type X, and come in various outer diameters.

    The ceramic BIOLOX® delta ball head is assembled with the corresponding titanium sleeve and is then placed over the titanium alloy tapers of an in-situ hip stem prosthesis. The titanium sleeve has an inner taper which fits the dimensions of a metallic hip stem prosthesis, and the BIOLOX® delta ball head has a taper which fits to the dimensions of the outer diameter of the titanium sleeve.

    AI/ML Overview

    This document is a 510(k) premarket notification for a medical device (BENCOX Delta Option Heads, a hip joint prosthesis component). It is a regulatory submission to the FDA demonstrating substantial equivalence to a legally marketed predicate device.

    Crucially, this document is NOT a study describing the performance of an AI/ML medical device. It details the engineering and material properties of a physical orthopedic implant. Therefore, the questions related to AI/ML device performance, such as "effect size of how much human readers improve with AI vs without AI assistance," "standalone (i.e. algorithm only without human-in-the-loop performance)," "sample size for the training set," and "how the ground truth for the training set was established," are not applicable to this document.

    The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to the non-clinical (bench) testing performed to demonstrate the device's safety and effectiveness compared to predicate devices, rather than clinical performance or AI/ML algorithm validation.

    Here's a breakdown of the requested information based on the provided document:


    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table with specific acceptance criteria values and the device's reported performance against those criteria. It lists the types of non-clinical tests performed to demonstrate substantial equivalence. These tests are implicitly conducted against established engineering and material standards for orthopedic implants.

    Acceptance Criteria CategoryReported Device Performance (Summary)
    Mechanical PerformanceDemonstrated substantial equivalence to predicate devices. Specific tests include:
    Burst TestingPerformed
    Fatigue TestingPerformed
    Post-fatigue Burst TestingPerformed
    Pull-off TestingPerformed
    Torque-out TestingPerformed
    Biocompatibility/SafetyDemonstrated substantial equivalence to predicate devices. Specific tests include:
    Range of MotionPerformed
    Corrosion Testing and AssessmentPerformed
    Pyrogen Testing (USP<161>, ANSI/AAMI ST72)Conducted, met recommended limits per FDA guidance, Endotoxin limit of < 20EU/Device for Bacterial endotoxin testing (BET).

    2. Sample sizes used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Sample Size: The document does not specify the sample sizes (number of units tested) for each non-clinical test (Burst, Fatigue, etc.). These are typically described in detailed test reports not included in this summary.
    • Data Provenance: The tests were performed by Corentec Co., Ltd. (manufacturer) based in the Republic of Korea. The data is non-clinical/bench testing data, not human subject data, so "retrospective or prospective" doesn't apply in the same way.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    Not applicable. This is not an AI/ML device and the "ground truth" for mechanical testing is based on engineering specifications, material science, and well-established test methods (e.g., ISO standards, ASTM standards), not expert interpretation of medical images.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This is not an AI/ML device where image adjudication would be relevant. Mechanical testing results are objective measurements.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a physical orthopedic implant, not an AI/ML medical device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical orthopedic implant, not an AI/ML medical device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this device's performance relies on engineering specifications, material properties, and established international standards (e.g., ISO 6474-2 Type X for ceramic material, USP<161>, ANSI/AAMI ST72 for pyrogenicity) for mechanical and biocompatibility testing of hip prostheses. Equivalence is demonstrated to legally marketed predicate devices which conform to these standards.

    8. The sample size for the training set

    Not applicable. This is a physical orthopedic implant, not an AI/ML medical device.

    9. How the ground truth for the training set was established

    Not applicable. This is a physical orthopedic implant, not an AI/ML medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223223

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-02-27

    (133 days)

    Product Code
    Regulation Number
    888.3358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BENCOX Mirabo Z Cup Cortinium of BENCOX Total Hip System is intended for Cementless use in total hip arthroplasty in primary or revision surgery for the following conditions:

    a. Non-inflammatory degenerative joint disease, such as avascular necrosis, osteoarthritis, traumatic arthritis

    b. Inflammatory degenerative joint disease, such as rheumatoid arthritis

    c. Treatment of non-union, femoral neck fracture, and trochantric fractures of the proximal femur with head involvement, unmanageable using other techniques

    d. Patients with failed previous surgery where pain, deformity, or dysfunction persists

    e. Revision of previously failed total hip arthroplasty

    Device Description

    The subject BENCOX Mirabo Z cup Cortinium shares key design features, materials, Indications for Use statements, geometry, and compatibility with other Corentec acetabular components marketed under the brand names BENCOX Mirabo Cup System and BENCOX Mirabo Z Cup Cortinium.

    The BENCOX Mirabo Z cup Cortinium is similar to the predicate devices BENCOX Mirabo Z Cup Cortinium cleared under K210614 and Bencox Mirabo Cups cleared under K220468, K172806, K162127, K120924 with respect to material - Titanium alloy (ASTM F136), and coated by pure titanium powder (ASTM F1580) through an additive manufacturing process, design, locking system, manufacturing (without coating processes), packaging and sterilization. This submission is only for the inclusion of specification of BENCOX Mirabo Z Cup Cortinium with external diameter 50mm.

    The manufacturing process including additive manufacturing is identical to the predicate. The subject 50mm acetabular shell is thinner than the predicate 50mm shells but it is not thinner than other sized shells in the predicate submission. Otherwise, the geometry of the features is identical to the predicate.

    The subject devices operate using the same fundamental scientific technology, have the same intended use and design features, employ the same materials of construction, are offered in the same product size scopes, and are implanted using a similar surgical technique and the same or similar instrumentation to legally marketed device cleared under K120924, K162127, K172806, K220468 and K210614.

    AI/ML Overview

    The provided text describes a 510(k) submission for a hip joint prosthesis, not an AI/ML medical device. Therefore, it does not contain information about acceptance criteria or a study proving that an AI/ML device meets those criteria.

    The document is a clearance letter from the FDA for a new size (50mm diameter acetabular cup) of an existing hip implant device, the BENCOX Mirabo Z Cup Cortinium. The submission focuses on demonstrating substantial equivalence to previously cleared devices through non-clinical testing of the physical properties and performance of the implant.

    Consequently, I cannot extract the information required in your request regarding acceptance criteria and a study for an AI/ML device. The document mentions tests like "Wear Testing as per ISO 14242-1 and 14242-2," "Cup Deformation as per ISO 7206-12," and "Shell Fatigue Testing as per ASTM F3090," which are standard tests for orthopedic implants. However, these are mechanical and material tests, not performance metrics for an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K222278

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-08-26

    (28 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LOSPA TKR System is intended for use in total knee arthroplasty surgery for the following indications:
    · Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis or avascular necrosis) or rheumatoid arthritis;
    · Post-traumatic loss of knee joint configuration and function;
    • Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability:
    · Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure.
    LOSPA TKR System is intended for cemented application only.

    EXULT Knee System is intended for the treatment of diseases as follows:
    · Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis or avascular necrosis) or rheumatoid arthritis;
    · Post-traumatic loss of knee joint configuration and function;
    • Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability:
    · Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure.
    EXULT Knee System is intended for cemented application only.

    Device Description

    The subject devices in this special 510(k) are the surgical instruments for the LOSPA Modular Knee System and EXULT Knee System, and submitted as a line extension of optional instruments for Corentec's FDA-cleared reusable orthopedic knee joint replacement instruments. The subject instruments are part of Corenter' 510(k)-cleared knee product lines and are required to facilitate total knee arthroplasty procedures.

    LOSPA Modular Knee System Instruments: Implant specific trials - the design of the connection part of the trials to the instrument has been revised due to customer's needs. Guide, alignment instruments - the design of the cutting guides and alignments instruments have been revised due to customer's needs.

    EXULT Knee System Instruments: AP sizer external rotation instrument and cutting block instruments have been developed to facilitate to check in posterior access during the operation based on US surgeon's request.

    AI/ML Overview

    The provided text does not contain information about the acceptance criteria or a study proving that a device meets acceptance criteria. The document is an FDA 510(k) clearance letter for Corentec Co., Ltd.'s LOSPA TKR System Instrumentation and EXULT TKR System Instrumentation. It primarily discusses the administrative details of the clearance, the indications for use of the devices, and a comparison to legally marketed predicate devices to establish substantial equivalence.

    Specifically, the document states:

    • No Clinical or Animal Testing: "No clinical or animal testing were required." (Page 6)
    • Non-Clinical Testing: "The following non-clinical laboratory testing and/or engineering analysis were performed to determine substantial equivalence: ・ Dimensions measurement testing ・ Assembly testing" (Page 6)

    Therefore, I cannot provide the requested information, which requires details about acceptance criteria, device performance studies, sample sizes, expert involvement, ground truth establishment, or multi-reader multi-case studies. The clearance was based on dimensional measurements and assembly testing, not on clinical performance metrics typically associated with acceptance criteria for device efficacy or diagnostic accuracy.

    Ask a Question

    Ask a specific question about this device

    K Number
    K212034

    Validate with FDA (Live)

    Device Name
    LOSPA TKR System
    Manufacturer
    Date Cleared
    2021-12-09

    (163 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LOSPA TKR System is intended for use in total knee arthroplasty surgery for the following indications:

    · Painful, disabling joint disease of the knee resulting from non-inflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis or avascular necrosis) or rheumatoid arthritis;

    · Post-traumatic loss of knee joint configuration and function;

    · Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability;

    · Correction of unsuccessful osteotomy, arthrodesis, or failure of previous arthroplasty procedure.

    LOSPA TRK System is intended for cemented application only.

    Device Description

    The Additional components being added to the LOSPA TKR System are:

    Instrumentation (Tibial Insert Trial) -

    The subject LOSPA TKR System components specification inclusions are a line extension of Instrumentation (Tibial Insert trial). The following is the additional components.

    A) Instrumentation (Tibial Insert Trial)

    A copy of a final tibial prosthesis designed to be used during total knee arthroplasty to determine the correct alignment, size, and fit of the final prosthesis. It is one of a set of trial knee prostheses that match the different anatomical structures of the knee joint, and may be used in conjunction with a knee femoral component trial prosthesis and a tibial baseplate trial prosthesis. This instrument is a reusable device that must be sterilized prior to use.

    Additional Tibial Insert Trials are designed based on Tibial Insert Trials of predicate device cleared LOSPA TKR System Instrumentation under K110404 & K130673 & K160157 & K192507 & K200395. There is one eliminated size, 26T of each design (CR and PS), each for left and right sides. For both CR and PS designs, the ranges of dimensions are the same. The components have slightly modified height. Except for the differences of height, lengths are identical to the previously cleared Tibial insert trials. The subject LOSPA TKR System is available in nine proportional sizes.

    This Tibial Insert Trials are made of Propylux conforming to ASTM D4101: Standard Classification System and Basic for Specification for Polypropylene Injection and Extrusion Materials.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the LOSPA TKR System, specifically focusing on the inclusion of new instrumentation (Tibial Insert Trial). It does not contain information about acceptance criteria or a study proving the device meets acceptance criteria in the context of performance metrics like sensitivity, specificity, accuracy, or reader improvement.

    The document is a regulatory submission for a medical device (knee joint prosthesis instrumentation) and details:

    • Device Name: LOSPA TKR System
    • Manufacturer: Corentec Co., Ltd.
    • Regulatory Classification: Class II, Product Codes JWH, MBH
    • Indications for Use: Total knee arthroplasty for specific conditions (osteoarthritis, rheumatoid arthritis, post-traumatic loss of function, moderate varus/valgus/flexion deformity, revision of unsuccessful procedures). Intended for cemented application only.
    • Device Description: The submission is for additional instrumentation (Tibial Insert Trial) for the existing LOSPA TKR System. These trials are sized for correct alignment, size, and fit of the final prosthesis, are reusable, and made of Propylux.
    • Substantial Equivalence: The device is being submitted as substantially equivalent to previously cleared LOSPA Total Knee System products (K110404, K130673, K160157, K192507, K200395).

    The information requested in the prompt (acceptance criteria, study details, sample sizes, ground truth, expert qualifications, adjudication, MRMC studies, standalone performance, training set details) is typically associated with studies proving the clinical or analytical performance of diagnostic or AI-enabled devices. This document pertains to the modification of an existing mechanical prosthetic system, specifically the inclusion of new instrumentation (a trial component), not a diagnostic algorithm or a device requiring such performance studies.

    Therefore, I cannot extract the requested information from the provided text because it does not contain data on:

    1. Acceptance criteria and reported device performance: No specific performance metrics (e.g., sensitivity, accuracy) are mentioned for the Tibial Insert Trial.
    2. Sample size, data provenance: Not applicable for this type of submission which is for mechanical instrumentation.
    3. Number/qualifications of experts, adjudication method: Not relevant for this type of device.
    4. MRMC study: Not relevant.
    5. Standalone performance: Not relevant.
    6. Type of ground truth: Not relevant.
    7. Training set sample size/ground truth establishment: Not relevant, as this is not an AI/algorithmic device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K211866

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-07-14

    (28 days)

    Product Code
    Regulation Number
    888.3358
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BENCOX Total Hip System is intended for cementless use in total or partial hip arthroplasty in primary or revision surgery for the following conditions:

    · non-inflammatory degenerative joint disease, such as avascular necrosis, osteoarthritis, traumatic arthritis;

    · Inflammatory degenerative joint disease, such as rheumatoid arthritis;

    · Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques;

    · patients with failed previous surgery where pain, deformity, or dysfunction persists;

    · revision of previously failed total hip arthroplasty.

    Device Description

    The Additional components being added to the BENCOX THR System are:

    • Instrumentation (Head trial, Bencox Hybrid PE Liner Trial - STD/ELV, Bencox Mirabo PE Liner Trial - STD/ELV, Shell Trial, Bipolar Cup Trial, Bipolar Cup Trial Ring, Head Impacting Part, Liner Impacting Part)

    The Bencox Hip Instrumentation is a set of accessories to be used with Bencox Hip Implants. The instruments are designed to be simple, conventional, and accurate and all parts of which are used for their respective procedures by qualified orthopedic surgeons. The parts of the instruments are made of Propylux and/or SUS along with colorants which are biocompatible and used in medical industry for decades and cleared for use in previous premarket notifications of Corentec.

    The Trials are used to match the different anatomical structures of the hip joint and the Impacting Parts are used to combine the components together. These instruments are reusable devices that must be sterilized prior to use.

    The trials and impacting parts of this submission are made of Propylux and/or SUS conforming to ASTM D4101: Standard Classification System and Basis for Specification for Polypropylene Injection and Extrusion Materials, and ASTM F899:

    Standard Specification for Wrought Stainless Steels for Surgical Instruments, respectively.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for a medical device, the BENCOX THR System. This type of submission is for demonstrating substantial equivalence to a legally marketed predicate device, rather than proving a device's performance against specific acceptance criteria through a clinical study.

    Therefore, the document does not contain the following information:

    • A table of acceptance criteria and reported device performance.
    • Sample size used for a test set or its data provenance.
    • Number of experts used to establish ground truth or their qualifications.
    • Adjudication method for a test set.
    • Information on a multi-reader multi-case (MRMC) comparative effectiveness study, including effect size.
    • Information on standalone (algorithm-only) performance.
    • Type of ground truth used (expert consensus, pathology, outcomes data, etc.) for a test set.
    • Sample size for a training set.
    • How ground truth for a training set was established.

    Explanation from the document:

    The document states under "Non-Clinical Testing":
    "The designs, dimensions and function of additional instruments are similar with predicate devices under K162127. Additional performance testing is unnecessary since the trial is not implanted."

    And under "Clinical Testing":
    "Clinical testing for BENCOX THR System Instrumentation were not required as a basis for substantial equivalence."

    This explicitly indicates that no clinical performance studies, which would typically involve testing against acceptance criteria, were conducted or required for this 510(k) submission. The basis for clearance is the demonstrated substantial equivalence to predicate devices through technical characteristics and non-clinical engineering analysis (e.g., dimensions).

    Ask a Question

    Ask a specific question about this device

    K Number
    K200267

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-03-06

    (32 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The LOSPA IS Spinal Fixation Systems are intended to provide immobilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). When used as an anterior screw fixation system, The LOSPA Spinal Fixation Systems are indicated for patients with degenerative disc disease which is defined as back pain of the discogenic origin with degeneration of the disc confirmed by history and radiographic studies, Spondylolisthesis, fracture, spinal stenosis, spinal deformities such as scoliosis, tumor, pseudoarthrosis, or revision of failed fusion attempts.

    Device Description

    The LOSPA IS Spinal Fixation System is a temporary, multiple component system comprised of a variety of non-sterile, single use components, made of titanium alloy or cobalt chrome alloy, that allow the surgeon to build a spinal implant construct. The system is attached to the vertebral body by means of screw fixation to the non-cervical spine. The LOSPA® ISTM Spinal Fixation System consists of an assortment of pedicle screws, set screws, lateral offsets, bone screws and screw bodies. The LOSPA® ISTM Spinal Fixation System implants are not compatible with components or metal from any other manufacturer's system.

    AI/ML Overview

    I am unable to find the acceptance criteria and the study that proves the device meets the acceptance criteria from the provided text. The document appears to be a 510(k) premarket notification approval letter for a medical device, which primarily focuses on establishing "substantial equivalence" to existing predicate devices rather than providing detailed acceptance criteria and performance study results in the format requested.

    The "Performance Data" section mentions that "Performance testing - mechanical testing was carried out to demonstrate substantial equivalence and the subject device performed either similar or better than comparable predicate devices." It also lists the types of mechanical tests performed (e.g., ASTM F1717, ASTM F543) but does not provide specific acceptance criteria or the reported device performance values for these tests within the document.

    Therefore, I cannot populate the table or answer the specific questions about sample size, data provenance, ground truth, expert qualifications, or MRMC studies. This type of detailed performance data is typically found in the full 510(k) submission, which is not included here.