Search Filters

Search Results

Found 4 results

510(k) Data Aggregation

    K Number
    K003050

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2000-12-26

    (85 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K974320

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1998-02-03

    (78 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    2 - 120
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CryoGen Cardiac Cryosurgical System is indicated for use in minimally invasive cardiac surgery procedures, including surgical treatment of cardiac arrhythmias. The cardiac cryoprobes freeze the target tissue and block the electrical conduction pathway by creating an inflammatory response, or cryonecrosis.

    Device Description

    The CryoGen Cardiac Cryosurgery System consists of three components: the Console, which contains the compressors and the dewar. The CryoGen Cardiac Cryosurgery System is a cryosurgical unit incorporating a gas cooled cryoprobe. Operation of the cryosurgical System is based on the Joule-Thomson principle in which pressurized coolants are expanded through a small orifice to produce cooling. The device is intended to produce extreme cold. Temperatures of -100 to -120 °C are developed at the tip of the cryoprobe.

    AI/ML Overview

    The provided text (K974320) does not contain information about studies conducted to prove device performance against acceptance criteria. It primarily focuses on the device description, intended use, technological characteristics, and its substantial equivalence to predicate devices for regulatory clearance.

    Therefore, I cannot extract the following information from the provided text:

    1. A table of acceptance criteria and the reported device performance
    2. Sample sized used for the test set and the data provenance
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    4. Adjudication method for the test set
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, or its effect size
    6. If a standalone performance (algorithm only) study was done
    7. The type of ground truth used
    8. The sample size for the training set
    9. How the ground truth for the training set was established

    This 510(k) summary is a premarket notification for a Class II medical device, and substantial equivalence to existing devices is typically the primary focus for clearance, rather than extensive clinical efficacy studies with predefined acceptance criteria as might be required for a Class III device or a novel technology. The "studies" mentioned refer to comparisons with predicate devices regarding design, materials, and principle of operation, rather than performance studies against specific clinical endpoints.

    Ask a Question

    Ask a specific question about this device

    K Number
    K972662

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1997-10-01

    (90 days)

    Product Code
    Regulation Number
    878.4350
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CryoGen Cryosurgical System is intended for use in the surgical ablation of tissue by the application of extreme cold in the fields of dermatology, general surgery, neurosurgery, thoracic surgery, E.N.T., gynecology, oncology, proctology and urology.

    Device Description

    The CryoGen Cryosurgery System consists of three components: the disposable Control Unit, the Cryoprobe and the Console, which contains the compressor system, microprocessor and user interface. The CryoGen Cryosurgery System is a cryosurgical device incorporating a gas cooled cryoprobe. Operation of the System is based on the Joule-Thomson principle in which pressurized coolants are expanded through a small orifice to produce cooling. The device is intended to destroy tissue by the application of extreme cold. Temperatures of -100 to -120 ℃ are developed at the tip of the cryoprobe. These temperatures are within the range of the predicate devices and is sufficient to achieve the desired tissue effect. None of the coolant comes into contact with the patient or physician. In addition, none of the coolant gases are exhausted into the atmosphere, the system is closed. There is no coeling along the shaft of the probe nor at the handle that is held by the user during treatment.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the CryoGen Cryosurgery System, which focuses on establishing substantial equivalence to predicate devices rather than proving a new device's meeting of acceptance criteria through a dedicated study with performance metrics.

    Therefore, many of the requested details about acceptance criteria, specific studies, sample sizes, and expert adjudication are not available in the provided document, as they are not typically required for a 510(k) submission where substantial equivalence to existing devices is claimed.

    However, I can extract and infer some information based on the content related to substantial equivalence.

    Here's a breakdown of what can be gleaned and what is explicitly not mentioned:

    1. Table of Acceptance Criteria and Reported Device Performance

    This information is not provided in the document. A 510(k) summary primarily focuses on demonstrating substantial equivalence to predicate devices. It doesn't typically include a table of specific acceptance criteria (e.g., minimum temperature achieved, speed of freezing, lesion size) and a corresponding performance report from a novel study designed to meet those criteria.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided. The document discusses the technical characteristics and intended use in comparison to predicate devices, but it does not describe a "test set" in the context of a performance study with specific metrics.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    This information is not provided. There is no mention of a test set requiring ground truth establishment by experts.

    4. Adjudication Method for the Test Set

    This information is not provided. As there's no mention of a test set requiring adjudication, this method is not discussed.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and the Effect Size

    This information is not provided. The device is a physical cryosurgical unit, not an AI or imaging diagnostic tool. An MRMC study is irrelevant in this context.

    6. If a Standalone (Algorithm only without human-in-the-loop) Performance Study was done

    This information is not provided. This is not an AI or algorithmic device; therefore, a standalone performance study in that context is not applicable. The device's operation is based on the Joule-Thomson principle, a physical process.

    7. The Type of Ground Truth Used

    This information is not provided. As there's no mention of a performance study requiring ground truth, its type is not discussed.

    8. The Sample Size for the Training Set

    This information is not provided. The device is not an AI model requiring a training set.

    9. How the Ground Truth for the Training Set was Established

    This information is not provided. Not applicable to this type of device.


    What is available/inferable from the document regarding "acceptance criteria" and "proof":

    While not framed as "acceptance criteria" in the traditional sense of a performance study, the entire 510(k) submission acts as a demonstration that the device acceptably performs similarly to predicate devices.

    • Implicit Acceptance Criteria (Substantial Equivalence): The primary "acceptance criteria" for a 510(k) clearance is demonstrating substantial equivalence to legally marketed predicate devices. This means that the device must be as safe and effective as a legally marketed device in the same class and for the same indications for use.

    • "Study" (Comparison to Predicates): The "study" that proves the device meets these implicit criteria is the comparison of its technological characteristics and intended use to predicate devices.

      • Device Performance (as reported in the document):
        • Principle of Operation: "Operation of the System is based on the Joule-Thomson principle in which pressurized coolants are expanded through a small orifice to produce cooling."
        • Temperature Achieved: "Temperatures of -100 to -120 ℃ are developed at the tip of the cryoprobe."
        • Sufficiency of Temperature: "These temperatures are within the range of the predicate devices and is sufficient to achieve the desired tissue effect."
        • Safety Features: "None of the coolant comes into contact with the patient or physician. In addition, none of the coolant gases are exhausted into the atmosphere, the system is closed. There is no cooling along the shaft of the probe nor at the handle that is held by the user during treatment."
        • Technological Characteristics Comparison: "The technological characteristics of the CryoGen Cryosurgical System 2 are the same as those of the CryoGen Cryosurgical System 1, and the other predicates listed elsewhere... These devices are substantially equivalent in terms of design, materials, principle of operation, product specifications and sterilization."
        • Intended Use Comparison: "The CryoGen Cryosurgical System is intended for use in the surgical ablation of tissue by the application of extreme cold in the fields of dermatology, general surgery, neurosurgery, thoracic surgery, E.N.T., gynecology, oncology, proctology and urology. This intended use is identical to the intended use for the predicate cryosurgical devices."
    • Ground Truth (for Substantial Equivalence): The "ground truth" for determining substantial equivalence is the established safety and effectiveness of the identified predicate devices. The new device is evaluated against these known safe and effective precedents.

    In summary, the provided document does not describe a study in the sense of a performance trial with specific calculated metrics against predefined acceptance criteria for a novel device. Instead, it details a 510(k) submission which relies on demonstrating the new device's equivalence to existing, already-cleared devices based on shared design, materials, principle of operation, product specifications, sterilization, and intended use. The "proof" is this detailed comparison allowing the FDA to conclude "substantial equivalence."

    Ask a Question

    Ask a specific question about this device

    K Number
    K964971

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1997-03-28

    (106 days)

    Product Code
    Regulation Number
    878.4350
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1