510(k) Data Aggregation

    K Number
    K131522

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-08-09

    (73 days)

    Product Code
    Regulation Number
    888.3070
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Core Pedicle Screw System is a posterior pedicle screw system indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

    In addition, the Core Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

    The Core Hook System is intended for use as a posterior, noncervical, nonpedicle system indicated for degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma(i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis); tumor; pseudoarthrosis; and failed previous fusion. The Core Hook System can be used in conjunction with Core Pedicle Screw System.

    Device Description

    The Core Pedicle Screw System is a top-loading multiple component, posterior spinal fixation system that consists of pedicle screws, rods, hooks, set screws, connectors, and a transverse (cross) linking mechanism. The Core Pedicle Screw System allows surgeons to build a spinal implant construct to stabilize and promote spinal fusion.

    AI/ML Overview

    This document is a 510(k) Premarket Notification for the Core Pedicle Screw System. It seeks clearance to market the device based on its substantial equivalence to a previously cleared predicate device.

    Here's an analysis of the provided information concerning acceptance criteria and studies:

    Acceptance Criteria and Device Performance:

    The document states: "The subject device is identical to the previously cleared Rexious System in terms of indications for use, device dimensions, instrumentation, manufacturing process, cleaning/sterilization process and labeling." This implies that the acceptance criteria for the Core Pedicle Screw System are met by demonstrating its identical nature to the predicate. The "reported device performance" is implicitly that it performs the same as the predicate device.

    Acceptance CriterionReported Device Performance
    Indications for UseIdentical to predicate device (Dio Medical Rexious Spinal Fixation System)
    Device DimensionsIdentical to predicate device
    InstrumentationIdentical to predicate device
    Manufacturing ProcessIdentical to predicate device
    Cleaning/Sterilization ProcessIdentical to predicate device
    LabelingIdentical to predicate device

    Study Information:

    The document explicitly states: "Non-clinical testing was not performed as part of this submission."

    Therefore, regarding the specific questions about studies:

    1. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective): Not applicable. No test set was used for this submission. The device is being cleared based on substantial equivalence to a predicate device.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience): Not applicable. No test set was used.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable. No test set was used.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is a medical device (spinal fixation system), not an AI diagnostic tool. No MRMC study was conducted.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is a medical device, not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc): Not applicable. No original ground truth was established for this submission. The "truth" is established by the predicate device's prior clearance and demonstrated safety and effectiveness.
    7. The sample size for the training set: Not applicable. No algorithm was trained.
    8. How the ground truth for the training set was established: Not applicable. No algorithm was trained.
    Ask a Question

    Ask a specific question about this device

    K Number
    K131520

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-07-11

    (44 days)

    Product Code
    Regulation Number
    888.3060
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nexus Anterior Cervical Plate System is intended for anterior fixation to the cervical spine. The specific clinical indications include:

    degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.

    Device Description

    The Nexus Anterior Cervical Plate System consists of a variety of shapes and sizes of main plates, screws, sub-plates, rivets and associated instruments. The sub-plate is pre-assembled to the main plate and designed to prevent screws from backing out using the elastic behavior during the screw insertion.

    The rivets are pre-assembled to the main plate, which firmly attach the sub-plate component to the main plate. Each component is color anodized to differentiate the screw type and diameter and to facilitate the surgical process.

    The plates range in length to accommodate one, two, three, and four level procedures. Main plates are available from 20mm to 110mm. Screws are available in lengths from 10mm to 20mm in 2mm increments. The screws have either a 3.5mm or 4.0mm diameter. They are provided in fixed self-tapping, variable self-tapping, fixed self-drilling and variable self-drilling configurations.

    AI/ML Overview

    This document describes a 510(k) submission for the Nexus Anterior Cervical Plate System. This is a medical device for spinal fixation, not an AI/ML device, and therefore the requested information regarding acceptance criteria and studies (like sample size, ground truth, expert opinions, MRMC studies, standalone performance, training set) is not applicable in the context of this submission.

    The core of this submission is a demonstration of substantial equivalence to a previously cleared predicate device (Dio Medical Rex Anterior Cervical Plate System, K121862). This means the device is being cleared because it is deemed to be as safe and effective as a device already on the market, not through a process involving performance metrics against acceptance criteria tested in a clinical or AI performance study.

    Here's why the AI/ML specific questions are not applicable:

    • No AI/ML Component: The Nexus Anterior Cervical Plate System is hardware (plates, screws, sub-plates, rivets) used for physical fixation in cervical spine surgery. It is a traditional medical device, not a software algorithm, diagnostic tool, or any other device that would typically involve AI/ML.
    • Substantial Equivalence (Predicate Device): The submission explicitly states: "The subject device is identical to the previously cleared Rex System in terms of indications for use, device dimensions instrumentation, manufacturing process, cleaning/sterilization process and labeling." And "Non-clinical testing was not performed as part of this submission." This indicates that the approval relies on the fact that the new device is essentially the same as one already approved, and therefore, extensive new testing (especially AI/ML performance testing) is not required.

    Therefore, I cannot provide a table of acceptance criteria and reported device performance or answer questions 2-9 from your prompt because they relate to the evaluation of AI/ML models or clinical studies that were not performed or required for this type of 510(k) submission.