Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K150187

    Validate with FDA (Live)

    Date Cleared
    2015-05-19

    (112 days)

    Product Code
    Regulation Number
    870.1250
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cordis ELITECROSS™ Support Catheter is intended to facilitate the intraluminal placement of diagnostic/ interventional devices beyond stenotic lesions (including chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention, and to deliver saline or contrast medium. Additionally, ELITECROSS™ can be used as an accessory with the FRONTRUNNER® XP CTO Catheter.

    Device Description

    The ELITECROSS™ Support Catheter is a single-use, 5F sheath-compatible sterile catheter designed to provide additional support to the distal portion of ancillary diagnostic/interventional devices, including the FRONTRUNNER® XP CTO Catheter, as well as to deliver saline or contrast medium. After crossing the occlusion with the ancillary device, the ELITECROSS™ may be used to facilitate placing a guide wire across the occlusion.

    The ELITECROSS™ Support Catheter device is a single lumen torqueable tube containing a full-length PTFE inner liner that is surrounded by a stainless steel braid, which is further encompassed by a polymer jacket, and features a final external hydrophilic coating on the distal 40 cm of the catheter body. The proximal end utilizes a molded hub with a luer fitting for flushing, with winged tabs designed to facilitate maneuvering and torqueing in the vasculature, while the distal tip contains a radiopaque marker band for visibility under fluoroscopy. The ELITECROSS™ Support Catheter will be available in various configurations and several lengths. The ELITECROSS™ Support Catheter is provided sterile (by EO) and intended for single use only.

    AI/ML Overview

    This document is a 510(k) Pre-market Notification for the ELITECROSS Support Catheter. It seeks to demonstrate substantial equivalence to a predicate device, the Cordis Micro Guide Catheter ELITE. Therefore, the information provided focuses on the substantial equivalence and performance testing compared to the predicate, rather than a standalone study proving the device meets de novo acceptance criteria for an AI/ML device.

    Because this is a submission for a medical device (catheter) and not an AI/ML device, the typical acceptance criteria and study design elements you've requested for AI/ML performance (e.g., sample size for test sets, data provenance, number of experts for ground truth, MRMC studies, standalone performance) are not applicable in the context of this document.

    Instead, the "acceptance criteria" for a medical device like this are generally related to its functional performance, physical dimensions, material properties, and biological safety, demonstrating that it performs as intended and is as safe and effective as a legally marketed predicate device.

    Here's how to interpret the provided information in relation to your request, keeping in mind the device type:


    1. A table of acceptance criteria and the reported device performance

    Based on the document, the "acceptance criteria" are implied by the performance characteristics tested, demonstrating equivalence to the predicate and ensuring the device functions as intended. The reported performance is that the device "meets applicable performance requirements" and "continues to meet all previous performance specifications" of the predicate.

    Acceptance Criteria (Implied)Reported Device Performance
    Material & Design Equivalence: Identical design, materials, dimensions, configurations, operating principle, control mechanism, and site of manufacture to the predicate.The subject device is identical to the predicate in these aspects.
    Intended Use Equivalence: Same intended use as the predicate.The subject device has the same intended use as the predicate.
    Labeling Changes Justification: Labeling modifications (trade name, sheath compatibility, Indications for Use edits) do not alter fundamental technology, operating principles, mechanism of action, or intended use, and do not raise new questions of safety and effectiveness.Supported by: Verification and validation activities, risk analyses, similarities to cleared reference device. Additional testing supported 5F CSI compatibility and delivery of saline/contrast. Labeling modifications do not raise new questions of safety and effectiveness.
    Functional Performance (Specific Tests): Catheter Sheath Introducer (CSI) CompatibilityMeets requirements; additional testing supported 5F CSI compatibility.
    Functional Performance (Specific Tests): Static Burst TestingMeets applicable performance requirements.
    Functional Performance (Specific Tests): Flow Rate Performance TestingMeets applicable performance requirements.
    Overall Performance (Equivalence to Predicate): Continues to meet previous performance specifications of the predicate; critical clinical performance parameters unchanged.The ELITECROSS™ continues to meet all previous performance specifications for Micro Guide Catheter ELITE, and none of the critical clinical performance parameters have changed.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified in the provided document. For physical device testing, sample sizes are typically determined by statistical methods or industry standards but are not usually detailed in this summary section of a 510(k).
    • Data Provenance: Not specified nor is it typically relevant for this type of physical device performance testing. The tests are benchtop, laboratory evaluations.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable. This is not an AI/ML device where expert consensus on interpretations or diagnoses would be required for ground truth. Ground truth for a catheter involves objective physical and functional measurements (e.g., burst pressure, flow rate, dimensions).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable. As above, this is for AI/ML interpretative tasks, not for physical device performance validation.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is a physical medical device (catheter), not an AI/ML diagnostic or assistive tool. MRMC studies are not relevant here.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This is a physical medical device. There is no algorithm or "standalone" performance in the AI/ML sense.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Objective Technical Measurements: The "ground truth" for this type of device testing consists of objective, quantifiable measurements of physical properties and performance characteristics (e.g., dimensions, burst pressure, flow rates, compatibility with other devices). These are typically verified against engineering specifications and industry standards.

    8. The sample size for the training set

    • Not Applicable. This is a physical medical device, not an AI/ML device that requires a training set.

    9. How the ground truth for the training set was established

    • Not Applicable. No training set is involved.
    Ask a Question

    Ask a specific question about this device

    K Number
    K150836

    Validate with FDA (Live)

    Date Cleared
    2015-04-29

    (30 days)

    Product Code
    Regulation Number
    870.1250
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The OUTBACK Elite Re-Entry Catheter is intended to facilitate placement and positioning of guidewires and catheters within the peripheral vasculature. The OUTBACK Elite Re-Entry Catheter is not intended for use in the coronary or cerebral vasculature.

    Device Description

    The OUTBACK® Elite Re-Entry Catheter is a single-use device designed to facilitate placement and positioning of guidewires within the peripheral vasculature. The device consists of three primary elements: 1) Cannula, 2) Catheter shaft, and 3) Deployment handle with deployment control slide. The OUTBACK® Elite Re-Entry Catheter is supplied sterile and is available in two useable lengths.

    AI/ML Overview

    The provided document is a 510(k) summary for the OUTBACK Elite Re-Entry Catheter. It focuses on demonstrating substantial equivalence to a predicate device rather than providing a detailed clinical study for a novel device. Therefore, much of the requested information regarding acceptance criteria, study design, and ground truth establishment, which are typical for studies validating AI/software-driven medical devices, is not available in this document.

    However, I can extract the information provided about device performance testing:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of acceptance criteria with corresponding performance results in a quantitative manner as would be expected for an AI study. Instead, it states that "Design verification and validation testing demonstrate that the catheter continues to meet all previous performance specifications and that none of the critical clinical performance parameters have changed." and "The OUTBACK® Elite Re-Entry Catheter continues to meet all previous performance specifications and none of the critical clinical performance parameters have changed."

    The performance data listed are primarily related to physical, chemical, and biological properties of the catheter, not diagnostic accuracy or clinical outcomes as would be relevant for devices with AI components. The types of testing performed, and the general statement of conformity, are:

    Acceptance Criteria CategoryReported Device Performance
    Biocompatibility TestingCompliant with U.S. FDA GLP regulations (21 CFR Part 58) and ISO 10993-1:2009/Cor 1:2010. Specific tests performed: In vitro Cytotoxicity MEM Elution, In vitro Hemolysis (ASTM Extract & Direct Contact), USP <661> Containers - Plastics, Physicochemical Tests.
    Device Dimensional and Functional TestingAll previous performance specifications met. Specific tests performed: Device Joint Tensile Strength, Catheter Torqueability, Device Joint Torque to Failure.
    Packaging and Sterilization TestingAll previous performance specifications met. Specific tests performed: Sterilization Validation, Sterilization Loading Configuration Evaluation, Bioburden, EO residuals, Bacterial Endotoxin, NPRT, D-Value, Blue Dye Penetration, Peel Strength.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    This information is not provided in the document as the study described is a device verification and validation study, not a clinical study involving a test set of patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not applicable/provided as the study did not involve establishing ground truth from expert interpretation of a test set.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not applicable/provided.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable/provided. The device is a physical catheter, not an AI or software-driven diagnostic tool that would typically undergo an MRMC study.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This information is not applicable/provided. This device is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    This information is not applicable/provided. For the physical and performance tests, the "ground truth" would be established by validated test methods and specifications, not by expert consensus or pathology on patient data.

    8. The sample size for the training set

    This information is not applicable/provided. This is a physical device, not an AI model, and therefore does not have a training set in the AI sense.

    9. How the ground truth for the training set was established

    This information is not applicable/provided.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1