Found 2 results

510(k) Data Aggregation

    K Number
    K090720

    Validate with FDA (Live)

    Date Cleared
    2009-06-17

    (91 days)

    Product Code
    Regulation Number
    874.3302
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cochlear Baha BP100 sound processor is intended for use with the Baha auditory osseointegrated implant (for children aged 5 and older, or adults), or with the Baha Headband or Baha Softband (no age limitations), for the following patients and indications:

    • Patients who have a conductive or mixed hearing loss and can still benefit from sound amplification. The pure tone average bone-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) should be better than or equal to 45 dB HL.
    • Bilateral fitting of the BP100 is intended for patients who meet the above criterion in both ears, with bilaterally symmetric moderate to severe conductive or mixed hearing loss. Symmetrical bone-conduction thresholds are defined as less than a 10 dB average difference between ears (measured at 0.5, 1, 2, and 3 kHz), or less than a 15 dB difference at individual frequencies.
    • Patients who suffer from unilateral sensorineural deafness in one ear with normal hearing in the other ear (i.e. single-sided deafness or "SSD"). Normal hearing is defined as a pure tone average air-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) of better than or equal to 20 dB HL.
    • Baha for SSD is also indicated for any patient who is indicated for an airconduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.
    Device Description

    The Baha implant system works by combining a sound processor with an abutment and a small titanium implant placed in the skull behind the ear. The system is based on the process of "osseointegration" through which living tissue integrates with titanium in the implant. Thus, the titanium implant becomes one with the bone, allowing high-quality amplified and processed sound to be conducted via the skull bone directly to a cochlea with residual functionality. Baha sound processors can also be fitted as external (non-implanted) bone-conduction vibrators with either the Baha Headband or Baha Softband as an alternative to a conventional bone-conduction hearing aid.

    The Baha BP100 will be the newest addition to a current family of three marketed sound processors for use with the Baha auditory osseointegrated implant, or with the Baha Headband/Softband setup. In its initial release, it will provide a moderate gain ear-level sound processor that will serve as a premium-feature option to the currently marketed Baha Divino. At a later date, the BP100 platform may be used to provide a range of programmable products to meet end-user needs.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Cochlear Baha BP100, a bone conduction hearing aid. The submission focuses on demonstrating substantial equivalence to predicate devices rather than a de novo clinical study with specific acceptance criteria and performance metrics.

    Here's an analysis based on the provided text, addressing your questions:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not explicitly state formal "acceptance criteria" in terms of specific performance metrics (e.g., sensitivity, specificity, accuracy) for a new clinical study. Instead, the primary "acceptance criterion" for this 510(k) submission is demonstrating substantial equivalence to existing, legally marketed predicate devices.

    The reported device performance is framed in terms of comparability to the predicate Baha Divino.

    Aspect of Performance/ComparisonAcceptance Criterion (Implicit)Reported Device Performance
    Gain/OutputTo be "comparable to" or "essentially equivalent (or better) than" the Baha Divino sound processor."Bench testing shows that the gain/output of the Baha BP100 are comparable to those for the marketed Baha Divino sound processor..." "Bench testing shows that the Baha BP100 is essentially equivalent (or better) than the Baha Divino in terms of gain/output..." "Bench testing supports the proposed Indications For Use, since gain/output are equivalent to the Baha Divino..."
    Intended UseTo have the "same Indications For Use" as the Baha Divino.The BP100 offers gain/output comparable to the Baha Divino, and "Thus, it will be marketed for use for conductive or mixed hearing loss patients who have average bone-conduction thresholds up to < 45 dB HL (across 0.5, 1, 2, and 3 kHz), the same Indications For Use as cleared for marketing of the Baha Divino." The stated Indications for Use in the submission for BP100 match those of the Baha Divino for the relevant patient population.
    Technological CharacteristicsTo have "substantially equivalent technology" to other marketed sound processors in the Baha family."It has substantially equivalent technology, and intended use, as the other three currently marketed sound processors for the Baha system (Baha Divino, Baha Intenso, Baha Cordelle II)."
    Software/Programming SystemThe programming software and interface should be "substantially equivalent to other programming software that has been used for fitting of hearing devices that have digital signal processing algorithms."The programming software and interface "...is substantially equivalent to other programming software that has been used for fitting of hearing devices that have digital signal processing algorithms." The fitting software is "...substantially equivalent to other programming software that has been used for fitting of hearing devices that have digital signal processing algorithms."
    Direct Bone Conduction (DBC) MeasurementThe intended use and process to accomplish DBC measurements should be "substantially equivalent to a procedure used by a previous hearing device cleared for marketing under the 510(k) process."The production of pure tones through the hearing device for standard audiometric measurements to be used in a prescription has the "same intended use, function, and technology as the predicate [K984547 for the LGOB test using the Resound digital 5000 series hearing devices]."
    Safety and Efficacy (Overall)To be considered safe and effective for the indicated patient population."Published data in the literature support the safety and efficacy of the Baha Divino for patients with average bone-conduction thresholds of < 45 dB HL (e.g. Kompis et al., 2007)." "...further clinical performance data are unnecessary to prove that the BP100 can successfully fit the same patient population..."

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: No specific sample size for a "test set" or a new clinical study involving human subjects for the Baha BP100 is reported. The primary evidence presented is bench testing comparing the BP100 to predicate devices.
    • Data Provenance: The document refers to "Published data in the literature" (Kompis et al., 2007) to support the safety and efficacy of the Baha Divino (a predicate device). This suggests the provenance is retrospective clinical literature on a different device, not new data generated specifically for the BP100. Bench testing data would be generated from the device itself.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This information is not applicable as no new clinical study with a "test set" requiring expert-established ground truth was conducted for the Baha BP100 for this submission. The submission relies on bench testing and previously published clinical data on predicate devices.

    4. Adjudication Method for the Test Set:

    This information is not applicable for the same reason as above. No new clinical test set requiring adjudication was performed.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done:

    No, a Multi Reader Multi Case (MRMC) comparative effectiveness study was not reported. The submission explicitly states that "further clinical performance data are unnecessary" given the bench testing equivalence to the Baha Divino and its existing clinical literature.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done:

    The device is a hearing aid, which requires a human user (patient). The "algorithm" here refers to the digital signal processing within the hearing aid. The document implicitly refers to standalone device performance in terms of its gain/output characteristics as measured by bench testing, independently of human interaction beyond fitting. However, this is not an "algorithm-only" study in the typical sense of AI diagnostics, but rather engineering performance of the device's internal processing.

    7. The Type of Ground Truth Used:

    For the demonstration of substantial equivalence, the "ground truth" implicitly relies on:

    • Bench Testing Data: Direct measurements of the BP100's gain/output characteristics, compared to similar measurements for the Baha Divino.
    • Predicate Device Clinical Performance: The established safety and efficacy of the Baha Divino (supported by published literature like Kompis et al., 2007) served as the "ground truth" for clinical performance for the patient population, which the BP100 is then argued to serve equally well due to its comparable technical performance.

    8. The Sample Size for the Training Set:

    This information is not applicable. The Baha BP100 is a medical device, not an AI/ML algorithm that is "trained" in the typical sense. Its digital signal processing algorithms are designed and programmed, not learned from a dataset.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable as there is no "training set" for the device's inherent functionality described in the conventional AI/ML context. The device's design and programming are based on established audiological principles and engineering practices for hearing aids.

    Ask a Question

    Ask a specific question about this device

    K Number
    K080363

    Validate with FDA (Live)

    Device Name
    BAHA CORDELLE II
    Date Cleared
    2008-04-10

    (59 days)

    Product Code
    Regulation Number
    874.3302
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Baha Cordelle II sound processor is intended for use with the Baha auditory osseointegrated implant for the following patients and indications;

    • . Patients who have a conductive or mixed hearing loss and can still benefit from sound amplification. The pure tone average bone-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) should be better than or equal to 65 dB HL.
    • Bilateral fitting of the Cordelle II is intended for patients who meet the above e criterion in both ears, with bilaterally symmetric moderate to severe conductive or mixed hearing loss. Symmetrical bone-conduction thresholds are defined as less than a 10 dB average difference between ears (measured at 0.5, 1, 2, and 3 kHz), or less than a 15 dB difference at individual frequencies.
    • Patients who suffer from unilateral sensorineural deafness in one ear with normal # hearing in the other ear (i.e. single-sided deafness or "SSD"). Normal hearing is defined as a pure tone average air-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) of better than or equal to 20 dB HL.
    • . Baha for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.
    Device Description

    The Baha system works by combining a sound processor with an abutment and a small titanium implant placed in the skull behind the ear. The system is based on the process of "osseointegration" through which living tissue integrates with titanium in the implant. Thus, the titanium implant becomes one with the bone, allowing high-quality amplified and processed sound to be conducted via the skull bone directly to a cochlea with residual functionality.

    The Cordelle II is one of three currently marketed sound processors for use with the Baha auditory osseointegrated implant. It is the only analog signal processing and body-worn sound processor, and it offers the highest power output of all the devices.

    AI/ML Overview

    The provided text describes the Baha® Cordelle II hearing aid, focusing on an expanded indication for use. Here's an analysis of the acceptance criteria and supporting studies based on the provided input:

    Acceptance Criteria and Device Performance

    The core of this submission is to expand the audiometric fitting range for the Baha Cordelle II. The original acceptance criterion for conductive and mixed hearing loss was a bone-conduction threshold of < 45 dB HL. The proposed expanded criterion is < 65 dB HL.

    Acceptance Criteria (Expanded)Reported Device Performance (Implied by supporting studies)
    For patients with conductive or mixed hearing loss, the pure tone average bone-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) should be better than or equal to 65 dB HL. This replaces the previous standard of < 45 dB HL.The Baha Cordelle II provides higher gain and maximum output levels than other Baha sound processors, allowing patients with bone-conduction hearing loss up to 65 dB HL to significantly benefit from the device. Studies show improved audiological outcomes for this expanded range.
    For bilateral fitting, patients should meet the above criterion in both ears, with bilaterally symmetric moderate to severe conductive or mixed hearing loss. Symmetrical bone-conduction thresholds are defined as less than a 10 dB average difference between ears (measured at 0.5, 1, 2, and 3 kHz), or less than a 15 dB difference at individual frequencies.Implied: The bilateral fitting performance is considered consistent with the expanded unilateral indication, as the symmetry criteria focus on suitability for bilateral application of the device's extended capabilities.
    For patients with unilateral sensorineural deafness (SSD) in one ear with normal hearing in the other ear, "normal hearing" is defined as a pure tone average air-conduction hearing threshold (measured at 0.5, 1, 2, and 3 kHz) of better than or equal to 20 dB HL. (This indication was already existing, and not explicitly changed in the context of the Cordelle II's expanded audiometric range, but included in the overall indications.)Implied: The Cordelle II provides effective sound conduction for single-sided deafness, consistent with its general function for bone-anchored hearing, and is suitable for patients who cannot use AC CROS devices.
    Baha for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS. (This indication was already existing, and not explicitly changed in the context of the Cordelle II's expanded audiometric range, but included in the overall indications.)Implied: As an alternative to AC CROS for SSD patients, the Cordelle II demonstrates its capability to route sound effectively in these cases.

    Study Information for Device Performance

    The submission relies on published clinical data to support the expanded indications for use.

    1. Sample size used for the test set and the data provenance:

      • The document refers to studies by van der Pouw et al. (1998), Tjellstrom et al. (2001), and Bosman et al. (2006). The specific sample sizes for these individual studies are not provided in the given text.
      • Data Provenance: The studies are "published clinical data" and "studies that were not sponsored by the applicant." This suggests they are retrospective analyses of existing patient data or prospective clinical trials conducted independently of Cochlear Americas. The countries of origin for the data are not explicitly stated, but authors' affiliations in the references (e.g., Scandinavian Audiology, International Journal of Audiology, Otolaryngologic Clinics of North America) suggest an international context, likely including European data.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This information is not provided in the submission. Since the device is a hearing aid and the studies likely focus on audiological outcomes, the "ground truth" would implicitly be established through standard audiological assessments (e.g., pure tone audiometry, speech perception tests) conducted by qualified audiologists and/or ENT physicians, but the specific number or qualifications of these experts are not detailed in the context of establishing a specific ground truth for a test set for this submission.
    3. Adjudication method for the test set:

      • Not applicable / Not provided. The studies referenced are clinical performance studies, not typically involving an adjudication panel for a test set in the way an imaging AI algorithm might. The outcomes are based on measurable audiological data.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC study was not done. This is not an AI-based device, nor is it an imaging device requiring human reader interpretation. The studies focus on the direct clinical effectiveness of the device itself by measuring audiological improvement.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. The Baha Cordelle II is a physical hearing aid that works in conjunction with a patient's auditory system. Its performance is measured in a human-in-the-loop context (i.e., when worn by a patient).
    6. The type of ground truth used:

      • The "ground truth" for these clinical studies implicitly relies on audiological outcome measures. This would include:
        • Pure-tone average bone-conduction thresholds.
        • Hearing level (dB HL) measurements.
        • Potentially speech recognition scores or other functional hearing assessments.
      • These are considered clinical outcomes data directly reflecting the patient's hearing ability with the device.
    7. The sample size for the training set:

      • Not applicable. The Baha Cordelle II is an analog hearing aid, not a machine learning algorithm that requires a "training set." The device's design and functionality are based on established audiological principles and hardware, not iterative training on data.
    8. How the ground truth for the training set was established:

      • Not applicable. As there is no training set for an AI algorithm, there is no ground truth established in this context. The device's performance relies on its physical and electronic design to process sound effectively.