510(k) Data Aggregation

    K Number
    K971169

    Validate with FDA (Live)

    Date Cleared
    1998-02-17

    (326 days)

    Product Code
    Regulation Number
    866.3830
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cambridge Biotech Human Lyme B. burgdorferi IgG Western Blot is intended for use in testing human serum samples which have demonstrated positive or equivocal responses using EIA or IFA test procedures to provide supportive evidence of infection with Borrelia burgdorferi.

    The Cambridge Biotech Human Lyme B. burgdorferi IgG Western Blot can be used at any time following onset of symptoms. It should also be used for follow up when (1) only IgM antibodies were originally detected, (2) lgG antibodies were detected but were not considered significant, or (3) previously tested seronegative individuals are shown to develop antibodies by EIA or IFA test procedures.

    The assay is not intended for use as a screening assay, nor should it be used for analysis of serum from patients who have not demonstrated symptoms of Lyme Disease.

    Device Description

    The device is a Western Blot assay. Proteins and other antigenic components of the Borrelia spirochete are fractionated by Polyacrylamide Gel Electrophoresis in the presence of Sodium Dodecylsulfate. The separated proteins are electrophoretically transferred from the gel to nitrocellulose membranes, which are subsequently blocked to minimize non-specific binding and cut into strips. These nitrocellulose strips with Borrelia burgdorferi antigens are then reacted with diluted serum and controls (positive and negative sera of defined reactivity) during an incubation period.

    During the incubation period, human antibodies specific to the B. burgdorferi antigens, if present in the sample or control, will bind to the antigen to which they have affinity. Unbound serum and non-specific antibodies are washed from the strip. Detection of bound IgG antibodies is accomplished by reacting and incubating the strips with a solution anti-human IgG antibodies conjugated with alkaline containing phosphatase. Unbound conjugate antibodies are removed by washing. The qualitative assessment of the detected IgG antibodies is then accomplished by the reaction of the alkaline phosphatase with a chemical substrate, which is cleaved into a colored, insoluble product that can be visualized. The determination of the reactivity of each unknown specimen is accomplished by comparison of the identified, visualized bands to the Band Identifying and Band Intensity Controls.

    AI/ML Overview

    This document describes the Cambridge Biotech Human Lyme Borrelia burgdorferi IgG Western Blot kit. Here's an analysis of its acceptance criteria and the study that proves it meets those criteria:

    Acceptance Criteria and Reported Device Performance

    CriterionAcceptance Criteria (Implicit)Reported Device Performance
    SpecificityHigh percentage agreement for negative controls and non-Lyme disease samples.100% (95% CI: 99.8%-100.0%) from 1062 total normal donor and disease specimens.
    Sensitivity (Overall)Adequate detection of Lyme disease in well-characterized samples, particularly in later stages.Varies by disease presentation and draw time. Overall from 287 specimens: - Before Treatment (<1 month): 21% - After Treatment (<1 month): 19% - Lyme Late (2-12 months): 88%
    PrecisionConsistent results across multiple replicates and sites for controls.100% agreement for disposition of six IgG Controls across three sites. 92% agreement for presentation of diagnostic band.
    ReproducibilityHigh agreement across different sites and comparison to expected results for a reference panel.100% agreement for IgG disposition scores for 20 specimens across four sites. 87.5% of diagnostic bands scored identically. 94% overall agreement with expected IgG band scores.
    Threshold DeterminationAbility to differentiate weakly reactive positive samples from highly reactive negative samples.Demonstrated in preclinical testing comparing intensities of 5 weakly reactive Lyme antibody-positive samples to 5 highly reactive Lyme antibody-negative samples.

    Note on Acceptance Criteria: The document implicitly defines acceptance criteria through the presented performance metrics. Explicit pre-defined thresholds for acceptance (e.g., "Sensitivity must be >X%") are not directly stated but are inferred from the reported results being deemed acceptable for 510(k) clearance.

    Study Information

    2. Sample Size Used for the Test Set and Data Provenance:

    • Specificity Test Set: 1062 samples. These included "normal donor (from endemic and non-endemic regions) and disease specimens." The specific types of disease specimens (other than Lyme) are not detailed, but they are implied to be non-Lyme conditions to assess specificity.
    • Sensitivity Test Set: 287 "characterized Lyme disease specimens." These specimens were collected at different times after disease onset. The specimens were from 169 individual patients, with second draws on 92 and third draws on 36.
    • Precision Test Set: Six IgG Controls, tested in duplicate on each of three days at three test sites (18 replicates per control).
    • Reproducibility Test Set: 10 positive and negative specimens from the CDC 47-member panel (total 20 specimens, likely 10 positive, 10 negative, or 10 unique, tested for both).
    • Data Provenance: The document states that "Each of the clinical trial sites provided specimens that were well-characterized by the site." There is no explicit mention of the country of origin, but the "CDC 47-member panel" suggests U.S. data. The studies appear to be prospective for some data collection (e.g., "draw time from disease onset") and retrospective for the use of "archived Lyme Disease specimens" and the CDC panel.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications:

    • Number of Experts: Not explicitly stated.
    • Qualifications of Experts: Not explicitly stated. However, ground truth was established by "clinical diagnosis of Lyme Disease based on the probability of exposure/infection (tick bite and/or patient presence in potential tick habitats in an endemic region within 30 days prior to the onset of EM), Borrelia isolation by culture (where possible), or, for non-EM patients, the presentation of Late Lyme clinical manifestations (e.g., cardiac, joint-involvement, or neurological symptoms)." Additionally, "Each of the clinical trial sites provided specimens that were well-characterized by the site using Lyme-specific serological analyses, including EIA and Western Blot testing." This implies clinical specialists and laboratory experts were involved in establishing the ground truth.

    4. Adjudication Method for the Test Set:

    • Adjudication Method: Not explicitly described. The reliance on "clinical diagnosis" and "well-characterized by the site" suggests that the site's standard diagnostic procedures, likely involving consensus among clinicians or adherence to established guidelines, served as the adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    • No, an MRMC comparative effectiveness study involving human readers with and without AI assistance was not done. This device is a diagnostic kit (Western Blot assay) for detecting antibodies, not an AI-powered image analysis or diagnostic aid that would assist human readers in interpreting complex data.

    6. If a Standalone Study (i.e., algorithm only without human-in-the-loop performance) Was Done:

    • Yes, this was a standalone study. The performance characteristics of the Western Blot kit were evaluated directly, without human interpretation being the primary variable. The "reading" of the bands is part of the test procedure itself, and while human interpretation is involved, the study assesses the kit's ability to produce those bands accurately and reproducibly. The "scoring" of bands in the reproducibility study is an assessment of consistency of interpretation, rather than human performance with or without AI assistance.

    7. The Type of Ground Truth Used:

    • Combined Clinical, Laboratory, and Outcome Data:
      • Clinical Diagnosis: Based on exposure, EM presentation, or Late Lyme clinical manifestations (cardiac, joint, neurological symptoms).
      • Microbiological Evidence: Borrelia isolation by culture (where possible).
      • Laboratory Serology: Lyme-specific serological analyses (EIA and Western Blot testing) at the clinical trial sites.
      • Reference Panels: Centers for Disease Control Lyme Disease Serum Panel.
      • Outcomes Data: Implied by "After Treatment" and categorization of "Lyme Late" presentations, suggesting assessment based on disease progression and response to treatment.

    8. The Sample Size for the Training Set:

    • The document describes performance evaluation (test sets) rather than a distinct "training set" for an algorithm. This is a traditional diagnostic assay, not a machine learning algorithm. Therefore, the concept of a separate training set as understood in AI/ML is not directly applicable. The "characterized samples used for the establishment of Substantial Equivalence" and the "well-characterized, archived Lyme Disease specimens" served as the basis for demonstrating performance, which is analogous to a validation set in traditional diagnostic development.

    9. How the Ground Truth for the Training Set Was Established:

    • As noted above, there isn't a "training set" in the AI/ML sense. The ground truth for the specimens used to establish performance (analogous to a validation set) was established through:
      • Clinical Diagnosis: As detailed in point 7, based on patient history, symptoms, and clinical presentation.
      • Borrelia Isolation by Culture: Direct microbiological confirmation where feasible.
      • Lyme-specific Serological Analyses by Clinical Sites: EIA and Western Blot testing performed by the trial sites as part of their standard diagnostic procedures.
      • Reference Panel Consensus: The CDC Lyme Disease Serum Panel specimens likely have established ground truth based on extensive characterization.
    Ask a Question

    Ask a specific question about this device

    K Number
    K971170

    Validate with FDA (Live)

    Date Cleared
    1998-02-17

    (326 days)

    Product Code
    Regulation Number
    866.3830
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cambridge Biotech Human Lyme B. burgdorferi IgM Western Blot is an in vitro test system for the qualitative detection of human Immunoglobulin M (IgM) antibodies to Borrelia burgdorferi antigens in human serum. The Cambridge Biotech Human Lyme B. burgdorferi IgM Western Blot is intended for use in testing human serum samples which have demonstrated positive or equivocal responses using EIA or IFA test procedures to provide supportive evidence of infection with Borrelia burgdorferi.

    The Cambridge Biotech Human Lyme B. burgdorferi IgM Western Blot can be used during the acute phase (0-4 weeks of symptoms onset) of B. burgdorferi infection. After this period, infected patients are usually found to be Western Blot positive for IgG. A positive IgM test alone is not recommended for use in determining active disease in persons with illness of longer than one month.

    Device Description

    The device is a Western Blot assay. Proteins and other antigenic components of the Borrelia spirochete are fractionated by Polyacrylamide Gel Electrophoresis in the presence of Sodium Dodecylsulfate. The separated proteins are electrophoretically transferred from the gel to nitrocellulose membranes, which are subsequently blocked to minimize non-specific binding and cut into strips. These nitrocellulose strips with Borrelia burgdorferi antigens are then reacted with diluted serum and controls (positive and neqative sera of defined reactivity) during an incubation period. During the incubation period, human antibodies specific to the B. burgdorferi antigens, if present in the sample or control, will bind to the antigen to which they have affinity. Unbound serum and non-specific antibodies are washed from the strip. Detection of bound IgM antibodies is accomplished by reacting and incubating the strips with a solution containing anti-human IgM antibodies conjugated with alkaline phosphatase. Unbound conjugate antibodies are removed by washing. The qualitative assessment of the detected IgM antibodies is then accomplished by the reaction of the alkaline phosphatase with a chemical substrate, which is cleaved into a colored, insoluble product that can be visualized. The determination of the reactivity of each unknown specimen is accomplished by comparison of the identified, visualized bands to the Band Identifying and Band Intensity Controls.

    AI/ML Overview

    Here's an analysis of the provided 510(k) summary regarding the Cambridge Biotech Borrelia burgdorferi Human Lyme IgM Western Blot kit:


    Acceptance Criteria and Device Performance Study

    1. Table of Acceptance Criteria and Reported Device Performance

    The 510(k) summary does not explicitly state pre-defined acceptance criteria with specific numerical targets for sensitivity, specificity, precision, or reproducibility. Instead, it presents the achieved performance characteristics from the clinical trial. However, we can infer that the reported values met the implicit criteria for substantial equivalence.

    Performance MetricAcceptance Criteria (Implied)Reported Device PerformanceComments on Acceptability
    SpecificitySufficiently high to minimize false positives97.5% (95% CI: 96.6% to 98.5%)Met, considered high.
    SensitivitySufficiently high for detection in relevant patient populationsOverall (Mixed Draw Times/Treatment): 57% (Before Treatment, 0-2 months), 64% (After Treatment, 0-2 months), 39% (Lyme Late, 0-12 months)Met, but noted variability based on disease stage and treatment. Specificity appears to be prioritized.
    Precision100% agreement between sites and within sites for controls100% agreement across three sites for disposition of 6 IgM controls and 3 diagnostic bands.Met, excellent consistency.
    ReproducibilityHigh agreement between sites for positive/negative scores and band scoring100% agreement for IgM disposition scores (20 specimens) across four sites. 86.7% agreement for 3 diagnostic bands across sites. 94% overall agreement with expected IgM band scores.Met, very good inter-site consistency.

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Specificity Test Set: 1062 total samples
      • Data Provenance: Normal donor specimens (from endemic and non-endemic regions) and disease specimens. The document doesn't specify the exact countries of origin but mentions endemic and non-endemic regions, suggesting geographical diversity. It is retrospective, as these were "well-characterized, archived Lyme Disease specimens" and samples from diverse disease conditions.
    • Sensitivity Test Set: 296 total characterized Lyme disease specimens.
      • Data Provenance: "Characterized Lyme disease specimens" drawn at different times after onset of disease. These specimens came from "169 individual patients." Second draws were done on 92 patients, and third draws on 36 patients. Clinical diagnosis of Lyme Disease was based on "probability of exposure/infection (tick bite and/or patient presence in potential tick habitats in an endemic region within 30 days prior to the onset of EM), Borrelia isolation by culture (where possible), or, for non-EM patients, the presentation of Late Lyme clinical manifestations." Specimens were provided by "clinical trial sites" and "well-characterized by the site using Lyme-specific serological analyses, including EIA and Western Blot testing." This data is retrospective.
    • Precision Test Set: Six IgM Controls, tested in duplicate on each of three days at three test sites.
    • Reproducibility Test Set: Ten positive and ten negative specimens from the CDC 47-member panel (total 20 specimens), tested at four sites.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not explicitly state the number of experts used to establish the ground truth or their specific qualifications (e.g., radiologist with X years of experience). However, it notes that:

    • "characterized samples used for the establishment of Substantial Equivalence have a clinical diagnosis of Lyme Disease" based on specific criteria (exposure, EM, culture, Late Lyme symptoms).
    • "Each of the clinical trial sites provided specimens that were well-characterized by the site using Lyme-specific serological analyses, including EIA and Western Blot testing."

    This implies that medical professionals (likely physicians specializing in infectious diseases, and laboratory professionals performing serological analyses) at the clinical trial sites established the clinical diagnoses and characterization, which served as the ground truth. Specific credentials or numbers are not provided.

    4. Adjudication Method for the Test Set

    The document does not explicitly describe an adjudication method for the test set results (e.g., 2+1, 3+1 consensus). The clinical diagnosis and characterization by individual sites appear to have served as the ground truth. For precision and reproducibility, results were compared across multiple sites, with agreement percentages reported, suggesting a comparison or consensus model rather than a formal adjudication process described for initial ground truth establishment.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study comparing human readers with and without AI assistance was not done. This device is an in-vitro diagnostic (IVD) kit for laboratory use, not an AI-assisted diagnostic tool. Therefore, the concept of "human readers improve with AI vs. without AI" is not applicable here.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study Was Done

    Yes, the performance study effectively evaluates the device in a standalone manner. The reported sensitivity, specificity, precision, and reproducibility values reflect the performance of the IgM Western Blot kit itself, as interpreted by laboratory personnel following the kit's instructions. While human technicians read the visualized bands, the "algorithm" is the Western Blot test itself, and its performance is reported independently of any additional human diagnostic steps beyond the qualitative assessment of the bands per the kit's comparison method. The human interpretation of the bands is integral to the "device performance."

    7. The Type of Ground Truth Used

    The ground truth used was a combination of:

    • Clinical Diagnosis: Based on "probability of exposure/infection (tick bite and/or patient presence in potential tick habitats in an endemic region within 30 days prior to the onset of EM (ervthema migrans)), Borrelia isolation by culture (where possible), or, for non-EM patients, the presentation of Late Lyme clinical manifestations (e.g., cardiac, joint-involvement, or neurological symptoms)."
    • Lyme-Specific Serological Analyses: Including EIA and Western Blot testing performed by the clinical trial sites themselves.
    • CDC Lyme Disease Serum Panel: Used for reproducibility testing, which represents a highly characterized reference panel.

    This is primarily a combination of expert clinical consensus and established serological test results from the providing sites.

    8. The Sample Size for the Training Set

    The document does not explicitly mention a "training set" in the context of machine learning or algorithm development. For this type of IVD, the development and optimization of the assay (e.g., protein fractionation, antibody concentrations, detection methods) are iterative processes that precede the clinical validation. The "threshold determination" (Section 7) used a preclinical testing set of 3 weakly reactive positive samples and 10 highly reactive negative samples, which could be considered an internal "optimization/training" set for establishing cut-offs.

    9. How the Ground Truth for the Training Set Was Established

    As noted above, for the "threshold determination" set:

    • Preclinical Testing: The ground truth for these samples was presumably established during the assay development by comparing "weakly reactive Lyme antibody-positive samples" to "highly reactive Lyme antibody-negative samples." The characteristics of these samples (positive/negative for Lyme antibodies) would have been determined using established laboratory methods and clinical knowledge during the product development phase. The "negative specimens included both normal donors and samples from patients with potentially cross-reactive conditions or infections," indicating a robust characterization.