Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K233418

    Validate with FDA (Live)

    Date Cleared
    2024-05-09

    (212 days)

    Product Code
    Regulation Number
    870.2300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Biofourmis Everion+ (G2) provides continuous monitoring of the following vital signs in adults, 18 years of age or older, when at rest:

    • · Pulse rate
    • · Respiration rate
    • · Movement
    • · Skin temperature

    Biofourmis Everion+ (G2) also provides Blood oxygen saturation (SpO2) as a vital for continuous data collection in adults, 18 years of age or older, when at rest.

    Biofourmis Everion+ (G2) is intended for use in a hospital or home environment to support monitoring of wearers under the care of a trained healthcare professional. Biofourmis Everion+ (G2) is not intended for use in a critical care environment such as an ICU or operating room. The device information should not be the sole basis for clinical decisions.

    Device Description

    The Biofourmis Everion+ (G2) is a wireless multi-parameter vital-signs monitoring system. The Everion+ was includes an Application Programming Interface (API), which is intended to allow development of user interface applications that enable clinicians and medically-qualified personnel to access recorded vital signs information for patient monitoring.

    The system is comprised of the following components:

    • . Wearable device with multiple sensors
    • . Secure cloud environment with an API
    • Charger with accessories
    • . Armband

    The Everion+ G2 wearable is battery-operated with integrated sensors and wireless transceiver. The device is reusable and considered multi-patient use. After a healthcare professional (HCP) prescribes a device to a patient, they can clean the device according to the accompanying documentation for normal expected wear and buildup on the device. When the patient no longer needs the device for remote monitoring, the device can be returned to the HCP and undergo a low-level disinfection process, so it can be prescribed to a new patient.

    The wearable is worn on the upper arm via the adjustable armband that snaps to it. The armband is made of a stretchy material and has an adjustable clip to enable fitting to most adults. The patient contacting components primarily involved in permanent contact are the bottom device housing and the armband. The wearable continuously gathers multiparameter vital signs data from the person being monitored and securely transmits the data to the server component of the system, via cellular communication, when in range of a third-party receiver. When not in range, the collected data is stored on the Everion+ G2 wearable and transmitted when connection has been restored. Through APIs of the cloud environment, the data may be accessed from the cloud storage or integrated into a third-party application for monitoring.

    AI/ML Overview

    I am sorry, but the provided text from the FDA 510(k) submission does not contain the detailed information necessary to fully answer your request regarding the acceptance criteria and the study that proves the device meets them.

    Specifically, the document lists:

    • Indications for Use for the Biofourmis Everion+ (G2) for continuous monitoring of pulse rate, respiration rate, movement, skin temperature, and blood oxygen saturation (SpO2) in adults (18+) at rest in hospital or home environments.
    • A Summary of Non-Clinical Tests indicating that the device met applicable standards for electrical, mechanical, thermal safety (IEC 60601-1), electromagnetic compatibility (IEC 60601-1-2, ANSI IEEE C63.27, AIM 7351731), packaging (ISTA 3A), biocompatibility (ISO 10993-1), and cleaning/disinfection (ISO 17664-2).
    • A Summary of Animal & Clinical Studies mentions that SpO2 accuracy was assessed by comparing the device to arterial blood samples analyzed by CO-Oximetry, aiming for a root-mean-square (RMSE) comparison of no greater than 3.5% difference over a range of 70-100% SaO2, in accordance with ISO 80601-2-61 and FDA Guidance. It also mentions validation of skin temperature accuracy with laboratory test data per ISO 80601-2-56.

    However, the document does not provide:

    1. A table of specific acceptance criteria and the reported device performance for each vital sign, outside of the SpO2 RMSE target.
    2. Sample sizes used for the test set (clinical studies) for SpO2, and other parameters like pulse rate, respiration rate, movement, or skin temperature. It only broadly mentions "multiple subjects."
    3. Data provenance (country of origin, retrospective/prospective).
    4. Number of experts and their qualifications for establishing ground truth.
    5. Adjudication method.
    6. Whether an MRMC comparative effectiveness study was done, or any effect size of human readers improving with AI assistance.
    7. Whether a standalone (algorithm only) performance was done.
    8. Type of ground truth for all parameters (beyond CO-Oximetry for SpO2, and "corresponding FDA cleared reference devices" generally).
    9. Sample size for the training set.
    10. How the ground truth for the training set was established.

    The provided text focuses on demonstrating substantial equivalence to predicate devices and general compliance with regulatory standards, rather than a detailed breakdown of specific performance study results against defined acceptance criteria for each monitored parameter.

    Ask a Question

    Ask a specific question about this device

    K Number
    K182344

    Validate with FDA (Live)

    Device Name
    RhythmAnalytics
    Date Cleared
    2019-03-07

    (191 days)

    Product Code
    Regulation Number
    870.1425
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RhythmAnalytics is a software application for the assessment of cardiac arrhythmias using single-lead ECG data in subjects over 18 years of age. It is intended for use by a healthcare solution integrator to build web or mobile applications to let qualified healthcare professionals review and confirm the analytic result. The product supports downloading and analysing data recorded in compatible formats from any FDA cleared device used for the arrhythmia diagnostics such as Holter, event recorder, or other similar devices when of the rhythm is necessary. RhythmAnalytics can also be electronically interfaced, and perform analysis with data transferred from other computer based ECG systems, such as an ECG management system. RhythmAnalytics provides ECG signal processing and analysis, QRS and Ventricular Ectopic Beat detection, QRS feature extraction, interval measurement, heart rate measurement, and rhythm analysis. RhythmAnalytics is not for use in life supporting or sustaining systems or ECG monitor and Alarm devices.

    The product can be integrated into medical devices. In this case, the medical device manufacturer will identify the indication for use depending on the application of their device.

    RhythmAnalytics interpretation results are not intended to be the sole means of diagnosis. It is offered to physicians and clinicians on an advisory basis only in conjunction with the physician's knowledge of ECG patterns, patient background, clinical history, symptoms, and other diagnostic information.

    Device Description

    RhythmAnalytics consists of (1) A web application programming interface (API) which an authentic user to upload single-lead ECG data and reports ECG interpretation results, and (2) An automated proprietary algorithm, i.e., cardiac beats/arrhythmias detection which measures and analyzes ECG data to provide qualified healthcare professional supportive information for review.

    RhythmAnalytics is only intended to analyze recordings performed on adults (over the age of 18). RhythmAnalytics works in the following sequence:

    • Accept uploading digital ECG files via secure API;
    • Analyse the uploaded ECG using RhythmAnalytics proprietary algorithm, which detects cardiac beats/arrhythmias and intervals including:
      • Heart rate determination
      • RR Interval measurements
    • ORS
    • Non-paced arrhythmias
    • Non-paced ventricular arrhythmia calls
    • Ventricular ectopic beats
    • RhythmAnalytics returns the interpretation result to be reviewed by a qualified healthcare professional.
    AI/ML Overview

    The provided text describes the RhythmAnalytics device and its clearance by the FDA. Let's break down the information to address your specific questions about acceptance criteria and the study proving the device meets them.

    Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly present a table of acceptance criteria with specific numerical thresholds for metrics like sensitivity or specificity side-by-side with reported performance. Instead, it states that "Performance testing included the evaluation of sensitivity, specificity, and positive and negative values. All clinical input requirements were validated against a gold standard." It also mentions "No residual anomalies appeared during verification and software validation tests." and that "All software validation testing was completed successfully and met all requirements."

    While the document confirms these metrics were evaluated and requirements were met, it does not provide the specific numerical acceptance criteria (e.g., "Sensitivity must be >90%") nor the reported numerical performance values (e.g., "Achieved Sensitivity: 92%").

    Therefore, for question 1, I can only state what the document says was evaluated, but not the specific quantitative details.

    Acceptance Criteria (Implied)Reported Device Performance (Implied)
    Software functions as intendedAll software validation testing completed successfully and met all requirements. No residual anomalies appeared.
    Sensitivity (for arrhythmia detection)Evaluated and validated against a gold standard. (Specific values not provided)
    Specificity (for arrhythmia detection)Evaluated and validated against a gold standard. (Specific values not provided)
    Positive Predictive Value (for arrhythmia detection)Evaluated and validated against a gold standard. (Specific values not provided)
    Negative Predictive Value (for arrhythmia detection)Evaluated and validated against a gold standard. (Specific values not provided)
    UsabilityGeneral usability tests (login, upload, review, download) performed and met all requirements.
    Compliance with relevant standards (IEC 62304, FDA Guidance, AAMI/ANSI EC57:2012, IEC 62366-1)Followed and completed in compliance with listed standards and guidance documents.

    Let's address the remaining questions based on the provided text:

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not explicitly state the sample size used for the test set for performance evaluation (sensitivity, specificity, etc.) nor does it specify the data provenance (country of origin, retrospective/prospective). It only mentions "All clinical input requirements were validated against a gold standard."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The document does not provide information on the number of experts used to establish the ground truth for the test set, nor their specific qualifications. It only states that validation was performed "against a gold standard."

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    The document does not specify any adjudication method used for establishing the ground truth of the test set. It only refers to a "gold standard."

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The document does not mention a multi-reader multi-case (MRMC) comparative effectiveness study. The device is described as providing "supportive information for review" to "qualified healthcare professionals" and its interpretation results "are not intended to be the sole means of diagnosis." This suggests it's an assistive tool, but no study on human-AI collaboration performance or effect size is detailed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, a standalone performance evaluation was done. The "Summary of Performance Testing" section states, "Performance testing included the evaluation of sensitivity, specificity, and positive and negative values. All clinical input requirements were validated against a gold standard." This indicates the algorithm's performance was assessed independently against a "gold standard."

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The document explicitly states that "All clinical input requirements were validated against a gold standard." However, it does not specify the precise nature of this "gold standard" (e.g., whether it was expert consensus, pathology, or another form of definitive diagnosis).

    8. The sample size for the training set

    The document does not provide the sample size used for the training set of the proprietary algorithm.

    9. How the ground truth for the training set was established

    The document does not describe how the ground truth for the training set was established. It only refers to the algorithm as an "automated proprietary algorithm, i.e., cardiac beats/arrhythmias detection which measures and analyses ECG data."

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1