510(k) Data Aggregation

    K Number
    K234033

    Validate with FDA (Live)

    Date Cleared
    2024-05-06

    (138 days)

    Product Code
    Regulation Number
    876.5980
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ViSiGi® LUX is indicated for use in gastric and bariatric surgical procedures for the application of suction, stomach decompression, drainage of gastric fluids, irrigation and to serve as a sizing quide.

    Device Description

    VISIGi® LUX is a non-sterile, single patient use device for use in gastric and bariatric surgery. It is used to apply suction, decompress the stomach, drain gastric fluids, irrigate and to serve as a sizing guide. The design is derived from the predicate by addition of battery-powered LED lights. The device comprises a tube with a closed, rounded tip, and holes at the distal end. The proximal end includes a slide valve, integral suction regulator and a battery case. The non-rechargeable batteries power up an array of LEDs enclosed within the distal end of the tube. The purpose of the LED lights is to aid visualization of the tube by tissue transillumination during insertion and surgery under laparoscopic vision. The device is inserted by an anesthesiologist under supervision of the surgeon. The added lights do not change the intended use and are not required for the surgery to proceed safely.

    AI/ML Overview

    The provided text describes the 510(k) premarket notification for the ViSiGi LUX device. However, it does not contain information about acceptance criteria, device performance against specific metrics, sample sizes, ground truth establishment, expert qualifications, or MRMC studies for an AI/algorithm-driven device.

    The document focuses on demonstrating substantial equivalence of a physical medical device (a gastrointestinal tube with added LED lights) to a predicate device. The tests mentioned are for physical and electrical safety, biocompatibility, and functional performance (suction, drainage, irrigation) of the tube itself.

    Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving device performance as it relates to AI or algorithmic performance against specific metrics, as this information is not present in the provided text.

    Specifically:

    • 1. A table of acceptance criteria and the reported device performance: Not available for an AI/algorithm. The document lists general tests like "Suction Testing," "Drainage Testing," etc., and states "Passing these tests demonstrates substantial equivalence." It doesn't define quantitative acceptance criteria or specific performance numbers for these tests.
    • 2. Sample sized used for the test set and the data provenance: Not applicable in the context of an AI/algorithm for this device. The tests mentioned are laboratory bench tests on physical devices.
    • 3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience): Not applicable, as this is a physical device submission, not an AI/imaging algorithm.
    • 4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
    • 5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable, as this device does not involve human readers or AI assistance in image interpretation.
    • 6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    • 7. The type of ground truth used (expert concensus, pathology, outcomes data, etc): Not applicable for an AI/algorithm. Ground truth for a physical device typically refers to engineering specifications and performance benchmarks.
    • 8. The sample size for the training set: Not applicable.
    • 9. How the ground truth for the training set was established: Not applicable.

    The device, ViSiGi LUX, is a gastrointestinal tube with an added LED light subassembly. Its primary function is mechanical (suction, drainage, irrigation, sizing guide). The LED lights are for visualization, not for generating or processing diagnostic data that would typically involve AI or complex algorithmic performance evaluation metrics as requested in the prompt.

    Ask a Question

    Ask a specific question about this device

    K Number
    K151990

    Validate with FDA (Live)

    Date Cleared
    2015-09-11

    (53 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Tissue Removal System is indicated for the contained removal of tissue, including contained manual tissue sectioning, during minimally invasive surgical procedures.

    Device Description

    The Tissue Removal System is comprised of the Tissue Removal Pouch cleared under K150781 and an additional accessory Sectioning Device. It is provided sterile, and is for single patient use.

    The Tissue Removal Pouch of the Tissue Removal System includes a bag with a single large opening held open by a thin, opening ring. During laparoscopic surgery, the bag is placed within the peritoneal space via an existing port site. Tissue that has been resected is placed within the bag for isolation, containment and removal from the patient. The bag opening is exteriorized. Two halves of the Tissue Removal Pouch flip ring are attached to each other and to the bag is rolled around the flip ring by inverting the flip ring, in order to draw the resected tissue toward the port site.

    The resected tissue is then removed en bloc (for smaller specimens), or by first dividing the specimen using the accessory Sectioning Device. The Sectioning Device is comprised of a blunt wire, a flexible passer and a handle with a blunt hook. The passer is used to encircle the specimen with the wire. The handle includes a blunt hook that can be used to aid in the advancement of the passer. The specimen is divided by the manual application of a back and forth motion to the wire. Use of the accessory Sectioning Device permits division of the specimen while maintaining the containment effectiveness of the Tissue Removal Pouch

    AI/ML Overview

    Here's an analysis of the provided text regarding acceptance criteria and the supporting study, structured according to your request:

    Unfortunately, the provided document does not contain information related to an AI/ML device. The document is a 510(k) premarket notification for a medical device called "Tissue Removal System," which is a physical device used in surgery to contain and remove tissue.

    Therefore, many of your requested points, such as AI-related performance metrics, sample sizes for training or test sets for an algorithm, expert adjudication, or MRMC studies, are not applicable to this document.

    However, I can extract the information that is present regarding the non-clinical testing performed for this physical device.


    Description of Acceptance Criteria and Supporting Study for the Tissue Removal System

    The document describes non-clinical testing performed to demonstrate the safety and effectiveness of the "Tissue Removal System," particularly focusing on the integrity and containment capabilities of the Tissue Removal Pouch when used with its accessory Sectioning Device.

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria CategorySpecific Test/DescriptionReported Device Performance
    Containment IntegritySimulated Use Testing followed by Bubble Leak, Dye Penetration, and Viral Barrier TestingDemonstrated that the Tissue Removal System performs as intended and that the Tissue Removal Pouch maintains containment integrity after use with the accessory Sectioning Device.
    Extreme ContainmentExtreme Use Testing followed by Bubble Leak, Dye Penetration, and Viral Barrier TestingDemonstrated that the Tissue Removal System maintains its integrity and containment effectiveness after sectioning of multiple tissue specimens, far in excess of actual clinical conditions.
    Puncture ResistanceSectioning Device Puncture Resistance TestingDemonstrated that the flexible passer of the Sectioning Device will not puncture the Tissue Removal Pouch of the Tissue Removal System.
    Tear ResistanceSectioning Device Hook Tear Resistance TestingDemonstrated that the blunt hook of the hooked handle will not tear the Tissue Removal Pouch of the Tissue Removal System.
    Film Cutting ResistanceFilm Cutting TestingDemonstrated that forcing the wire of the Sectioning Device into the film of the Tissue Removal Pouch does not result in a cut to the Tissue Removal Pouch.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: The document does not specify the sample sizes (e.g., number of pouches, sectioning devices, or test repetitions) used for any of the non-clinical tests.
    • Data Provenance: The document does not specify the country of origin of the data or whether the tests were retrospective or prospective, though non-clinical tests are inherently prospective laboratory studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable. This document describes non-clinical engineering and material integrity tests on a physical device, not an AI/ML diagnostic system requiring expert interpretation or ground truth establishment in the traditional sense. The "ground truth" here is the physical performance of the device against predefined engineering standards (e.g., no leaks, no punctures, no tears).

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    • Not Applicable. As above, this is not an interpretive diagnostic study requiring adjudication. The outcomes are objective measurements of physical integrity (e.g., presence/absence of bubbles, dye penetration, tears, punctures).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is not a study involving human readers or AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This document pertains to a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • The "ground truth" in this context refers to the objective performance of the physical device as measured by specific non-clinical test methods. For example, for "Bubble Leak" testing, the ground truth for failure would be the observation of bubbles, and for "Dye Penetration," it would be the observation of dye. These are direct physical observations, not interpretive diagnoses.

    8. The sample size for the training set

    • Not Applicable. There is no "training set" as this is not an AI/ML model.

    9. How the ground truth for the training set was established

    • Not Applicable. There is no "training set."

    Summary of Device and Testing Context:

    The Tissue Removal System is a physical device for containing and removing tissue during minimally invasive surgery. Its key innovation over a predicate device is the inclusion of an accessory Sectioning Device that uses a blunt wire for dividing specimens, in contrast to predicate devices that might require sharp instruments.

    The non-clinical tests aim to prove that this new Sectioning Device does not compromise the primary function of the Tissue Removal Pouch, which is to maintain containment and integrity. The tests specifically assessed physical characteristics such as leak prevention, puncture resistance, and tear resistance under various conditions, including simulated and extreme use. The "conclusions" state that the device is "as safe and effective as, and performs as well as, or better than, the legally marketed predicate device" based on these non-clinical tests.