510(k) Data Aggregation

    K Number
    K061323

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2007-05-23

    (377 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For immediate or delayed surgical placement of a Dental implant in the anterior region and to allow immediate restoration (for cosmetic purposes).

    Device Description

    The Reliadent Dental Implant System includes surgical implants, healing cap, restoration abutments, and surgical instruments.

    Implants: Includes one or two step dental implant devices which are designed as conical and cylindrical shapes. They consist of various diameters with a range of 3.6mm-6.0mm and lengths with a range of 8mm-21mm. The internal and external hexagonal shapes are important to maintain the implant stability. One group of the products is HA coated. This surface has been modified to enhance the osseointegration. The dental implants are composed of medical grade 4 pure titanium.

    Cover screw and healing cap: The cover screw and healing caps are supplied together with the implants. They cover the internal body of implant to allow gum free space for connection between the implants and restoration abutments.

    Abutment: Abutments and accessories are the support part to prosthetic restoration. Screw retained abutments are included in the Reliadent Dental Implant System. The abutments are composed of medical grade 2 titanium.

    Surgical Instrument Kit: The surgical instruments include the implants installation set, abutment connections, and drill set. There are hand tools, drill bits of different sizes, and handles in these sets. The instrument kit is designed to be used with a wide range of commercially available implant devices.

    AI/ML Overview

    This document is a 510(k) summary for the Reliadent Dental Implant System. It primarily focuses on demonstrating substantial equivalence to a predicate device rather than presenting a performance study with detailed acceptance criteria and results. Therefore, many of the requested details are not present in the provided text.

    Here's an analysis of what can be extracted and what is missing:

    The provided text does not contain a study that proves the device meets specific acceptance criteria in the way a clinical or technical performance study would for a novel device. Instead, it demonstrates substantial equivalence to an already cleared predicate device (MIS Dental Implant System, K040807). This is a common pathway for device clearance, where the new device is shown to have the same intended use, similar technological characteristics, and equivalent performance to a legally marketed predicate device.

    Therefore, the requested information about acceptance criteria, reported device performance metrics (like sensitivity, specificity, accuracy, etc.), sample sizes for test/training sets, experts, adjudication methods, MRMC studies, or standalone performance is not applicable in the context of this 510(k) submission, as these types of studies were not presented or required for this type of submission.

    Here's a breakdown based on your request, highlighting what's available and what's explicitly missing/not applicable:


    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (Explicitly Stated)Device Performance (Reported)
    Substantial Equivalence to Predicate Device (MIS Dental Implant System, K040807) concerning:The Reliadent Dental Implant System:
    - Intended Use- Has the same intended use.
    - Material- Composed of medical grade 4 pure titanium (implants) and medical grade 2 titanium (abutments), similar to predicate.
    - Design- Similar design (conical and cylindrical shapes, various diameters and lengths, internal and external hexagonal shapes). Note: The new device has a "modified surface" (HA coated) to "enhance osseointegration," but this is presented as an improvement without specific quantified performance metrics against the predicate for this aspect.
    - Performance Characteristics- Stated to have "equivalent performance capabilities." (No specific quantitative performance metrics comparing to predicate are provided.)
    - Safety and Effectiveness- "Does not raise any additional concerns regarding safety and effectivity."

    2. Sample size used for the test set and the data provenance

    • Not applicable / Not provided. No specific test set or clinical study data proving performance for the Reliadent Dental Implant System were presented in this 510(k) summary. The submission relies on demonstrating similarity to a predicate device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not applicable / Not provided. No test set requiring expert-established ground truth was detailed in this substantial equivalence submission.

    4. Adjudication method for the test set

    • Not applicable / Not provided. No test set requiring adjudication was detailed.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable / Not done. This device is a dental implant system, not an AI-powered diagnostic tool. MRMC studies are irrelevant to this product.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Not applicable / Not done. This device is a physical medical device (dental implant), not an algorithm or software. Standalone performance studies in this context typically refer to AI algorithms, which is not relevant here.

    7. The type of ground truth used

    • Not applicable / Not provided. As no performance study with a test set was detailed, no ground truth was established within this submission. The "truth" here is the prior clearance and presumed safety and effectiveness of the predicate device.

    8. The sample size for the training set

    • Not applicable / Not provided. No training set was used. This is not an AI/machine learning device.

    9. How the ground truth for the training set was established

    • Not applicable / Not provided. No training set or associated ground truth was established.

    Summary of the "Study" that Proves the Device Meets Acceptance Criteria:

    The "study" in this context is the 510(k) submission itself, which aims to prove substantial equivalence to a predicate device (MIS Dental Implant System, K040807). The argument for meeting the "acceptance criteria" (which is primarily substantial equivalence) is made by:

    • Comparing Intended Use: The Reliadent system has the "same intended use" as the MIS Dental Implant System.
    • Comparing Materials: Both devices use medical grade titanium. The Reliadent system specifies medical grade 4 pure titanium for implants and medical grade 2 titanium for abutments.
    • Comparing Design: The Reliadent system includes "similar" surgical implants, healing caps, restoration abutments, and surgical instruments, with conical and cylindrical shapes, various diameters and lengths, and internal/external hexagonal shapes. A key difference mentioned is the "modified surface" (HA coated) on one group of products in the Reliadent system, intended to "enhance osseointegration." However, this is presented as an enhancement rather than a deviation requiring explicit comparative performance data with the predicate.
    • Concluding Equivalence in Performance and Safety: The submission states, "All other technological characteristics are similar and both devices show equivalent performance capabilities," and that the Reliadent system "does not raise any additional concerns regarding safety and effectivity."

    The FDA's letter (K061323) confirms their review of the submission and states that the device is "substantially equivalent" to legally marketed predicate devices, allowing it to proceed to market. The "Indications for Use" section further clarifies the specific use recognized by the FDA for the RDI Dental Implant System.

    Ask a Question

    Ask a specific question about this device

    K Number
    K043428

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-07-12

    (211 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Indicated for use in surgical and restorative applications for placement in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, in order to restore the patient's chewing function.

    Device Description

    The Reliadent Dental Implant System includes surgical implants, healing cap, restoration abutments, and surgical instruments.

    Implants: Includes one or two step dental implant devices which are designed as conical and cylindrical shapes. They consist of various diameters with a range of 3.6mm-6.0mm and lengths with a range of 8mm-17mm. The internal and external hexagonal shapes are important to maintain the implant stability. One group of the products is HA coated. This surface has been modified to enhance the osseointegration. The dental implants are composed of medical grade 4 pure titanium.

    Cover screw and healing cap: The cover screw and healing caps are supplied together with the implants. They cover the internal body of implant to allow gum free space for connection between the implants and restoration abutments.

    Abutment: Abutments and accessories are the support part to prosthetic restoration. Screw retained abutments are included in the Reliadent Dental Implant System. The abutments are composed of medical grade 2 titanium.

    Surgical Instrument Kit: The surgical instruments include the implants installation set, abutment connections, and drill set. There are hand tools, drill bits of different sizes, and handles in these sets. The instrument kit is designed to be used with a wide range of commercially available implant devices.

    AI/ML Overview

    The provided text is a 510(k) summary for the Reliadent Dental Implant System. It primarily focuses on demonstrating substantial equivalence to a predicate device based on similar intended use, materials, and design. This type of document generally does not include detailed acceptance criteria or extensive study data comparing performance against specific metrics. Instead, it relies on inferring equivalent performance based on similarities to a device already on the market.

    Therefore, for the specific questions regarding acceptance criteria and studies proving the device meets them, much of the requested information is not present in the provided document.

    Here's an analysis based on the available information:


    Acceptance Criteria and Device Performance

    1. Table of Acceptance Criteria and Reported Device Performance

    Not explicitly stated in the document.
    The 510(k) summary asserts "equivalent performance characteristics" to the predicate device, but it doesn't define specific acceptance criteria (e.g., minimum tensile strength, fatigue life, osseointegration rates) or present a table of results directly from tests on the Reliadent device against such criteria. The "performance" is primarily inferred from the similarities in design, materials, and intended use as compared to the predicate device.

    2. Sample Size Used for the Test Set and Data Provenance

    Not applicable/Not provided.
    The document does not describe a "test set" in the context of a performance study with specific data points. The assessment is qualitative, comparing the Reliadent Dental Implant System to the MIS Dental Implant System. There is no mention of a prospective or retrospective study, nor any country of origin for specific data.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    Not applicable/Not provided.
    No ground truth establishment process for a test set is described. The equivalency claim is based on the submitter's assertion and FDA's review of the submission.

    4. Adjudication Method for the Test Set

    Not applicable/Not provided.
    Since no specific test set or multi-reader evaluation is described, no adjudication method is mentioned.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No.
    There is no mention of an MRMC study or any study involving human readers. This device is a dental implant system, not an imaging or diagnostic device that would typically involve human reader studies.

    6. Standalone (Algorithm Only) Performance Study

    No.
    This device is a physical medical device (dental implant system), not an algorithm or AI software. Therefore, a standalone algorithm performance study is not applicable.

    7. Type of Ground Truth Used

    Not applicable/Not provided in the context of performance data.
    The "truth" in this submission relies on the established safety and effectiveness of the predicate device (MIS Dental Implant System) and the argument that the Reliadent system is substantially equivalent. There's no mention of using pathology, outcomes data, or expert consensus to establish a "ground truth" for a performance study of the Reliadent device itself.

    8. Sample Size for the Training Set

    Not applicable/Not provided.
    As this is a physical medical device and not an AI/ML algorithm requiring training data, the concept of a "training set" is not applicable.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable/Not provided.
    Since there's no training set, there's no ground truth establishment process for it.


    Summary of what the document does provide regarding "proof":

    The "proof" for the Reliadent Dental Implant System's safety and effectiveness in this 510(k) summary is based on substantial equivalence to an already legally marketed predicate device (MIS Dental Implant System, K040807).

    The key arguments for substantial equivalence are:

    • Same Intended Use: "Indicated for use in surgical and restorative applications for placement in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, in order to restore the patient's chewing function." This is identical to the predicate's intended use.
    • Similar Performance Characteristics: The document states the predicate has "equivalent performance characteristics in its intended use, material and design." For the Reliadent system, it asserts "All other technological characteristics are similar and both devices show equivalent performance capabilities."
    • Similar Design and Materials: Both systems include implants (conical/cylindrical shapes, various diameters/lengths, internal/external hexagonal shapes), cover screws/healing caps, abutments, and surgical instruments. Both use medical grade pure titanium, with the Reliadent system specifying grade 4 for implants and grade 2 for abutments.
    • One Differentiating Feature: The Reliadent system "is substantially the same as the currently marketed MIS dental implant with a modified surface. This surface promotes osseointegration." The implication is that this modification enhances a desirable characteristic (osseointegration) without introducing new safety or effectiveness concerns, and thus does not alter the substantial equivalence.

    In conclusion, the provided document is a regulatory submission for substantial equivalence, not a detailed scientific study report with specific acceptance criteria and performance data from clinical trials or bench testing for the Reliadent device itself. The evidence for meeting criteria is indirect, rooted in its similarity to a predicate device.