510(k) Data Aggregation

    K Number
    K233596

    Validate with FDA (Live)

    Date Cleared
    2023-11-09

    (1 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VarseoSmile TriniQ is indicated as an indirect restorative for both anterior restorations, including occlusal surfaces. The VarseoSmile TriniQ material is used for fabricating permanent restorations such as inlays, veneers, full crown and bridge restorations. VarseoSmile TriniQ can also be used for the fabrication of artificial teeth and temporary crowns & bridges.

    Device Description

    The Subject device is a light-cured methacrylate-based resin used in 3D printers to produce permanent or dental restorations such as crowns and bridges, inlays, onlays, veneers and full crown restorations including occlusal surfaces. The Subject device is used by a dental technician for the CAD/CAM manufacturing of temporary or permanent dental restorations. Restorations fabricated using the Subject device are one-time use, prescription-only devices. Commonly used dental CAD software is used by dental professionals to virtually design a fixed indirect restoration and generate an industry standard "STL" 3D dataset which reflects the intended shape and contour. The Subject resin is used within a validated manufacturing workflow to create the intended restoration. The Subject device is available in a variety of optional shades to reproduce the intended tooth shade of the restoration. Methacrylates are known materials, commonly used in the dental industry for fixed and removable prosthetic devices due to their physical-chemical, mechanical, and biocompatible properties. The Subject device is intended to be sold by the bottle and used with compatible hardware in computer-aided and manufacturing (CAD/CAM) system that includes the following: scanner, design software, additive printer, and post-cure unit.

    AI/ML Overview

    The provided text describes the acceptance criteria and study for the VarseoSmile TriniQ device. This device is a light-cured methacrylate-based resin used in 3D printers to produce dental restorations.

    Here's a breakdown of the requested information:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document indicates that the device was tested against and met the requirements of specific ISO standards. It mentions a flexural strength criterion.

    Acceptance CriterionReported Device Performance
    ISO 4049:2019 (Dentistry — Polymer-based restorative materials)Met requirements
    ISO 10477:2020 (Dentistry – Polymer-based crown and veneering materials)Met requirements
    ISO 22112:2017 (Dentistry – Artificial teeth for dental prostheses)Met requirements (in most cases; comparative testing used where not met)
    Flexural Strength≥ 100 MPa
    Biological EvaluationMet requirements based on ISO 10993-1, 10993-5, 10993-10, 10993-17, 10993-18, 10993-23, and ISO/TS 21726
    MRI SafetyMet requirements based on FDA guidance "Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment"
    Manufacturing Process ConsistencyDemonstrated consistency of the process output with that of the process input

    2. Sample Size Used for the Test Set and the Data Provenance:

    The document does not specify the sample size used for the test set in terms of the number of dental restorations or materials tested for each performance criterion. It generally refers to "Physical property testing" and "Confirmatory testing" without providing specific numbers of samples.

    The data provenance is non-clinical performance testing, meaning it's laboratory-based testing of the material's properties rather than human patient data. There is no mention of country of origin for the data; the testing is against international ISO standards.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts:

    This information is not applicable and therefore, not provided. The testing described is for material characteristics against engineering and biocompatibility standards, not for diagnostic accuracy or clinical outcomes that would require expert-established ground truth.

    4. Adjudication Method for the Test Set:

    This information is not applicable and therefore, not provided. Adjudication methods are typically used in studies involving human interpretation or clinical outcomes, not for laboratory material property testing.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If so, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance:

    This information is not applicable and therefore, not provided. The device described is a dental restorative material, not an AI-powered diagnostic or treatment assistance tool. No MRMC study was mentioned.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    This information is not applicable and therefore, not provided. The device is a material, not an algorithm.

    7. The Type of Ground Truth Used:

    The "ground truth" for the non-clinical performance testing is the established requirements and specifications defined by international ISO standards (e.g., ISO 4049, ISO 10477, ISO 22112, ISO 10993 series) and FDA guidance for MRI safety. For manufacturing process validation, the ground truth is the expected or desired output consistent with the process input.

    8. The Sample Size for the Training Set:

    This information is not applicable and therefore, not provided. This is a material, not a machine learning model, so there is no concept of a "training set."

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable and therefore, not provided. As there is no training set mentioned, there is no ground truth to be established for it.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201668

    Validate with FDA (Live)

    Date Cleared
    2020-06-23

    (4 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VarseoSmile Crown plus is indicated as an indirect restorative for both anterior and posterior restorations, including occlusal surfaces. The VarseoSmile Crown Plus material is used for fabricating permanent restorations such as inlays, onlays, veneers and full crown restorations.

    Device Description

    VarseoSmile Crown plus is a light-cured, methacrylate-based resin used in 3D printers for the production of permanent crowns, inlays, onlays and veneers. The Subject device is used by a dentist or dental technician for the CAD/CAM manufacturing of permanent dental restorations such as inlays, onlays, veneers and full crown prosthetics in compatible 3Dprinters. Restorations fabricated using the Subject device are one-time use, permanent, prescription-only devices. VarseoSmile Crown is suitable for restoration of occlusal surfaces. VarseoSmile Crown is cured externally to the patient by light sources within a 3D printer and post-curing device. The Subject device is a viscous solution consisting of methacrylate-based resins, dental glass filler, photo initiators and pigments. Commonly used dental CAD software is used by dental professionals to virtually design a fixed indirect restoration and generate an industry-standard "STL" 3D dataset which reflects the intended shape and contour. The Subject resin is used within a validated manufacturing workflow to create the intended restoration. The Subject device is available in a variety of optional shades to reproduce the intended tooth shade of the restoration.

    AI/ML Overview

    This document is for a dental material (VarseoSmile Crown Plus), not an AI/ML powered medical device. Therefore, a table of acceptance criteria and reported device performance for an AI/ML device, as well as the other requested information related to AI/ML device studies (sample sizes, ground truth establishment, expert qualifications, adjudication methods, MRMC studies, standalone performance), are not applicable to the provided text.

    The information provided focuses on demonstrating substantial equivalence of the dental material to predicate devices based on indications for use, technological characteristics, and non-clinical performance testing against established ISO standards for dental materials.

    Here's a breakdown of the relevant information from the document regarding the device's acceptance criteria and how it was shown to meet them:

    Acceptance Criteria and Reported Device Performance (Non-AI/ML Device):

    ParameterAcceptance Criteria (ISO Standard)Reported Device Performance (VarseoSmile Crown Plus)
    Flexural StrengthISO 4049 ≥ 100 MPa> 100 MPa
    ISO 10477 ≥ 50 MPa-
    Water AbsorptionISO 4049 ≤ 40 µg/mm³< 40 µg/mm³
    ISO 10477 ≤ 40 µg/mm³-
    Water SolubilityISO 4049 ≤ 7.5 µg/mm³< 7.5 µg/mm³
    ISO 10477 ≤ 7.5 µg/mm³-
    BiocompatibilityYesYes
    Manufacturing ConsistencyConsistent process outputValidation performed

    Study Information (Non-AI/ML Device):

    • Sample size for test set and data provenance: Not applicable to this type of device and testing. The performance testing is on the material itself, not on a "test set" of patient data.
    • Number of experts and qualifications for ground truth: Not applicable. Ground truth for material properties is established by international standards and laboratory testing, not expert consensus.
    • Adjudication method for test set: Not applicable.
    • MRMC comparative effectiveness study: Not applicable.
    • Standalone (algorithm only) performance: Not applicable.
    • Type of ground truth used: International Standards (ISO 4049, ISO 10477) for physical properties, and biocompatibility testing criteria.
    • Sample size for training set: Not applicable. This is not an AI/ML device that requires a training set.
    • How ground truth for training set was established: Not applicable.

    The document states that "Physical property testing was performed on the Subject device to ISO 4049:2009, Dentistry — Polymer-based restorative materials and ISO 10477:2018, Dentistry – Polymer-based crown and veneering materials. Results demonstrated the Subject device meets the property requirements of the referenced standards."

    For biocompatibility, it states: "The Subject device was evaluated for biocompatibility by way of the BEGO (K193533) Reference device." This implies that the biocompatibility of the VarseoSmile Crown Plus was established by demonstrating its similarity to a previously cleared device (BEGO VarseoSmile Temp, K193533) which likely had its biocompatibility established. This is a common approach in 510(k) submissions for material equivalence.