510(k) Data Aggregation

    K Number
    K993577

    Validate with FDA (Live)

    Date Cleared
    1999-12-01

    (41 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Antimicrobial susceptibility test discs are used for semi-quantitative susceptibility testing of bacteria by standardized agar diffusion. Cefotaxime/Clavulanic Acid, BBL™ Sensi-Disc™ and Ceftazidime/Clavulanic Acid BBL™ Sensi-Disc™ are intended for use for confirmatory tests for organisms that secrete Extended-spectrum ß-lactamases (ESBL)s as indicated in the Results section of the package insert and indicated below.

    Use of Cefotaxime/Clavulanic Acid, BBL™ Sensi-Disc™ and Ceftazidime/Clavulanic Acid BBL ™ Sensi-Disc™ together with Cefotaxime and Ceftazidime susceptibility discs for in vitro agar diffusion susceptibility testing are indicated when there is a need to perform a confirmatory test for ESBLs in Klebsiella spp. and Escherichia coli.

    Device Description

    Cefotaxime/Clavulanic Acid and Ceftazidime/Clavulanic Acid susceptibility test discs are prepared by impreanating high quality absorbent paper with accurately determined amounts of Cefotaxime, supplied by Marion Roussel, Inc., Kansas City, MO, and Ceftazidime, supplied by Glaxo Wellcome Operations, Cumbria, UK, respectively. Both discs are also impregnated with specific amounts of Clavulanic Acid supplied by SmithKline Beecham Pharmaceuticals, Piscataway, NJ.

    The disks are clearly marked with the agents: CTX/CLA and CAZ/CLA. Cefotaxime/Clavulanic Acid and Ceftazidime/Clavulanic Acid susceptibility test discs are provided in cartridges of 50 disks each and packaged separately.

    Agar diffusion methods employing dried filter paper discs impregnated with specific concentrations of antimicrobial agents were developed in the 1940's. In order to eliminate or minimize variability in the testing, Bauer et al. developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium.

    Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of these standardized procedures were those published by the U. S. Food and Drug Administration (FDA) and the World Health Organization (WHO). The procedure was adopted as a consensus standard by the National Committee for Clinical Laboratory Standards (NCCLS) and is periodically updated. The latest NCCLS documents are M2-A6' (1/97) and M100-S92 (1/99).

    Disks containing an antimicrobial agent are applied to the surface of Mueller Hinton Agar plates inoculated with pure cultures of clinical isolates. Following incubation, the plates are examined and the zones of inhibition surrounding the discs are measured and compared with established zone size ranges for the antimicrobial agents in order to determine which is most suitable for use in therapy. The determination as to whether the organism is susceptible (S), intermediate (I), or resistant (R) to an antimicrobial agent is made by comparing zone sizes to the interpretive criteria defined in the tables of NCCLS document M100-S9.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the studies performed for the Cefotaxime/Clavulanic Acid and Ceftazidime/Clavulanic Acid BBL™ Sensi-Discs, based on the provided text:

    Acceptance Criteria and Device Performance

    Acceptance CriteriaReported Device Performance
    Reproducibility (across sites, lots, and individuals)* Multisite/Multilot Reproducibility: "Expected results were obtained in all cases" for zone sizes and differences between single and combination disks. * Inter-individual Reproducibility: "All results met the acceptance criteria" for variability between individual tests by the same person and between participants.
    Performance with NCCLS M100-S9 Challenge Set (Jacoby)"Expected results were obtained in all cases."
    Accuracy (Comparison to Laboratory-Prepared Disks for ESBL Confirmation) * Correlation with laboratory disks * Expected outcomes for genotypic and non-ESBL strains * Overall performance accuracy (acceptance criteria for this specific accuracy study is implied to be 95% or higher based on the text "Overall performance accuracy was 95% and meets the acceptance criteria as outlined in the study protocol.")* Correlation: "All production disks results correlated with laboratory disks with 100% equivalency in performance." * Genotypic/Non-ESBL Strains: "Expected outcomes were met for all of the genotypic and non-ESBL strains." * Phenotypic Strains: "The phenotypic strains performed as expected with the exception of four K. oxytoca strains. These four strains were not detected as ESBL by the reference or test disks." * Overall Performance Accuracy: "Overall performance accuracy was 95% and meets the acceptance criteria as outlined in the study protocol." * QC Testing: "QC testing over the course of the study was acceptable. All expected outcomes were achieved during the screening test."

    Study Details

    The provided document describes several performance studies, primarily for validation and comparative equivalence to predicate devices, rather than a single comprehensive clinical trial.

    2. Sample sizes used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Reproducibility Studies:
      • Multisite/Multilot: Tested with NCCLS recommended negative and positive Quality Control organisms. Performed in triplicate at three test sites for ten days using three lots of disks. Specific number of QC organisms not provided.
      • Inter-individual: Ten organism strains of various resistance mechanisms. Three individuals tested the ten strains on three different days in triplicate, using one lot of test disks.
    • Jacoby Challenge Set: The study used the Jacoby challenge set of organisms. Specific number of organisms not provided.
    • Accuracy Testing: Involved "genotypic and phenotypic ESBL strains and non-ESBL strains." Specific number of strains not provided.
    • Data Provenance: Not explicitly stated, but given the context of a 510(k) submission to the US FDA and the mention of NCCLS standards, it's highly probable the studies were conducted in the US. The studies appear to be prospective, laboratory-based performance evaluations.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. The ground truth for these in vitro diagnostic devices is established by standardized laboratory methods (NCCLS M100-S9) and the inherent biological characteristics of the bacterial strains (e.g., genotypic ESBL producers, phenotypic ESBL characteristics). Human experts were involved in performing the tests and reading the results, but they were not adjudicating a "ground truth" in the sense of subjective interpretation of images or clinical outcomes.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable for establishing ground truth. The "adjudication" for the in vitro test results is based on objective measurements (zone diameters) and comparison to established interpretive criteria (≥5mm increase for ESBL confirmation). Variability between individuals reading zones was assessed in the inter-individual reproducibility study.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is an in vitro diagnostic susceptibility disc, not an AI-powered diagnostic tool for human readers. The study focuses on the performance of the physical disk, not on comparative effectiveness for human readers using AI.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, in essence. The Sensi-Discs themselves (the "device") are used to generate a physical result (zone of inhibition) that is then interpreted according to standardized criteria. The "performance" being evaluated is the ability of the discs to accurately produce these results and differentiate ESBL-producing organisms according to the NCCLS guidelines. The interpretation of the measured zone sizes is a standardized, objective process, not a subjective human interpretation that would require a "human-in-the-loop" assessment in the way AI applications are often evaluated.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth was established by:

    • Standardized interpretative criteria: NCCLS M100-S9 document, defining a ≥5mm increase in zone diameter as indicative of ESBL production.
    • Known characteristics of organism strains: This includes NCCLS recommended Quality Control organisms, the Jacoby challenge set organisms, and specifically characterized "genotypic and phenotypic ESBL strains and non-ESBL strains." This implies that the true ESBL status for these strains was determined through established laboratory methods (e.g., genetic sequencing for genotypic ESBLs, or other phenotypic gold standards).

    8. The sample size for the training set

    Not applicable. This device is a physical diagnostic disc used in an in vitro laboratory setting, not a machine learning or AI algorithm that requires a "training set" in the computational sense. The studies described are performance evaluations and validation studies.

    9. How the ground truth for the training set was established

    Not applicable (as above).

    Ask a Question

    Ask a specific question about this device

    K Number
    K984631

    Validate with FDA (Live)

    Date Cleared
    1999-11-04

    (309 days)

    Product Code
    Regulation Number
    866.3390
    Age Range
    All
    Reference & Predicate Devices
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BDProbeTec™ ET Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) Amplified DNA Assays, when tested with the BDProbeTec™ ET System, use Strand Displacement Amplification (SDA) technology for the direct, qualitative detection of Chlamydia trachomatis and Neisseria gonorrhoeae DNA in endocervical swabs, male urethral swabs, and in female and male urine specimens as evidence of infection with C. trachomatis, N. gonorrhoeae, or of co-infection with C. trachomatis and N. gonorrhoeae. Specimens may be from symptomatic or asymptomatic females for the BDProbeTec ET CT and GC Assays, from symptomatic or asymptomatic males for the BDProbeTec ET CT Assay, and from symptomatic males for the BDProbeTec ET GC Assay. A separate Amplification Control is an option for inhibition testing (BDProbeTec ET CT/GC/AC Reagent Pack).

    Device Description

    The BDProbeTec™ ET Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) amplified DNA assays utilize homogeneous SDA technology as the amplification method and fluorescent energy transfer (ET) as the detection method to test for the presence of CT and GC in clinical specimens.

    For each assay, the SDA reagents are dried in two separate microwell strips. First, the processed sample is added to the Priming Microwell which contains the amplification primers, fluorescent labeled detector probe, and other reagents necessary for amplification. However, because no enzymes are present in the priming microwell strips, no amplification occurs at this step. After incubation, the reaction mixture is transferred to the Amplification Microwell, which contains two enzymes (a DNA polymerase and a restriction endonuclease) necessary for SDA. It is in this latter microwell in which amplification and detection occurs. The Amplification Microwells are sealed to prevent contamination and then incubated in a thermally controlled fluorescent reader which monitors each test well for the generation of amplified products. The presence of CT and GC is determined by relating the BDProbeTec ET MOTA (Method Other Than Acceleration) scores for the sample to pre-determined cutoff values. The MOTA score is a metric used to assess the magnitude of signal generated as a result of the reaction.

    If the CT/GC Reagent Pack is used, each sample and control are tested in two discrete microwells: C. trachomatis and N. gonorrhoeae. Results are reported through an algorithm as positive or negative. If the CT/GC/AC Reagent Pack is used, each sample and control are tested in three discrete microwells: C. trachomatis, N. gonorthoeae, and the Amplification Control. The purpose of the Amplification Control is to identify a sample that may inhibit the SDA reaction. Results are reported through an algorithm as positive, negative, or indeterminate.

    AI/ML Overview

    This document describes the regulatory submission for the BDProbeTec™ ET Chlamydia trachomatis and Neisseria gonorrhoeae Amplified DNA Assays.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implied by the clinical performance results being deemed "substantially equivalent" to predicate devices by the FDA. The reported device performance is outlined in detail for both C. trachomatis (CT) and N. gonorrhoeae (GC) assays, with sensitivity and specificity values compared to both culture and "patient infected status." The tables below summarize these performances.

    Table 1: BDProbeTec™ ET CT Assay Performance (Compared to Patient Infected Status)

    Specimen TypeSymptomatic/Asymptomatic (S/A)Sensitivity (95% C.I.)Specificity (95% C.I.)
    Female SwabS88.7% (78.1-95.3)98.5% (97.1-99.4)
    A96.8% (89.0-99.6)97.9% (96.6-98.8)
    Total92.8% (86.8-96.7)98.1% (97.3-98.8)
    Female UrineS77.0% (64.5-86.8)98.2% (97.0-99.3)
    A83.9% (72.3-92.0)98.3% (97.0-99.1)
    Total80.5% (72.4-87.1)98.4% (97.4-99.0)
    Male SwabS95.5% (89.7-98.5)92.9% (89.9-95.3)
    A89.5% (66.9-98.7)97.0% (93.2-99.0)
    Total94.6% (89.1-97.8)94.2% (91.9-96.0)
    Male UrineS95.4% (89.6-98.5)89.4% (85.9-92.4)
    A89.5% (66.9-98.7)95.8% (91.6-98.3)
    Total94.5% (89.1-97.8)91.4% (88.7-93.6)
    Overall90.7% (87.8-93.1)96.6% (95.9-97.1)

    Table 2: BDProbeTec™ ET GC Assay Performance (Compared to Patient Infected Status)

    Specimen TypeSymptomatic/Asymptomatic (S/A)Sensitivity (95% C.I.)Specificity (95% C.I.)
    Female SwabS96.1% (86.5-99.5)99.3% (98.1-99.8)
    A97.4% (86.2-99.9)99.6% (98.9-99.9)
    Total96.6% (90.5-99.3)99.5% (98.9-99.8)
    Female UrineS83.7% (70.3-92.7)99.6% (98.6-100)
    A86.5% (71.2-95.5)99.3% (98.4-99.8)
    Total84.9% (75.5-91.7)99.4% (98.8-99.8)
    Male SwabS98.4% (95.5-99.7)94.8% (91.6-97.0)
    Male UrineS97.9% (94.7-99.4)94.4% (91.2-96.7)
    Overall95.8% (93.8-97.4)98.5% (98.2-99.0)

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: The final data analysis included 4108 C. trachomatis specimens and 4105 N. gonorrhoeae specimens, collected from 2109 patients. Paired specimens (swab and urine) were collected from 2020 of these patients.
    • Data Provenance: The data was collected from a multicenter study at seven geographically diverse clinical sites in the United States (implied by the FDA 510(k) submission). The study was prospective in nature, as it involved specimen collection specifically for the evaluation of the new assay.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not explicitly state the number of general medical experts or their specific qualifications (e.g., years of experience) who established the ground truth for the clinical study. However, the ground truth for C. trachomatis was established using:
    * Cell culture as a primary reference.
    * A "patient infected status" definition.

    For N. gonorrhoeae, the ground truth was established using:
    * Culture as a primary reference.
    * A "patient infected status" definition.

    These methods inherently involve expert interpretation (e.g., microbiologists for culture results, potentially infectious disease specialists or clinicians for patient infected status).

    4. Adjudication Method for the Test Set

    The document describes an adjudication method to define "patient infected status" when the primary culture method was negative but amplification assays were positive:

    • For C. trachomatis: A patient was considered infected if (1) the culture was positive, OR (2) positive results were obtained for both AMP1 (a commercially available amplification method, in either swab or urine) and a DFA test (performed from cell culture transport medium), OR (3) AMP1 was positive in both swab and urine paired specimens.
    • For N. gonorrhoeae: A patient was considered infected if (1) the culture was positive, OR (2) (in females) if AMP1 was positive in both swab and urine (paired specimens). For males, if AMP1 urine was positive and corresponding swabs were culture negative, a different commercially available amplification assay (AMP2) was performed from culture transport medium for confirmation.

    This suggests that an expert consensus or a defined algorithm (rather than a simple 2+1 or 3+1 reader adjudication) was used to establish the "patient infected status" ground truth under specific conditions.

    5. If a Multi-reader Multi-case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The study does not describe a multi-reader, multi-case (MRMC) comparative effectiveness study using a human-in-the-loop AI system. This device is a diagnostic assay, providing a qualitative (positive/negative) result, rather than an imaging or interpretive AI system requiring human reader assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, the clinical performance data presented in Tables 1 and 2 represent the standalone performance of the BDProbeTec™ ET assays. The "device performance" columns directly report the sensitivity and specificity of the BDProbeTec™ ET system compared to the established ground truth. There is no indication of human intervention in the interpretation of the assay's MOTA scores (Method Other Than Acceleration) to determine positive or negative results beyond the pre-determined cutoff values.

    7. The Type of Ground Truth Used

    The ground truth used was a combination of:

    • Expert Reference Standard (Culture): C. trachomatis cell culture and N. gonorrhoeae culture were used as primary reference standards.
    • Composite Reference Standard ("Patient Infected Status"): For cases where culture was negative but other amplification assays showed positivity, a "patient infected status" was derived using a predefined algorithm involving the predicate amplification assay (AMP1) and, for CT, a Direct Fluorescent Antibody (DFA) test, and for male GC, an additional amplification assay (AMP2). This composite reference standard aims to capture true infections that might be missed by culture alone.

    8. The Sample Size for the Training Set

    The document does not explicitly state a separate "training set" for the BDProbeTec™ ET assay's algorithm. For in vitro diagnostic devices like this, the "algorithm" (i.e., the cut-off value for the MOTA score) is typically established during analytical validation (including studies like Limit of Detection, reproducibility, and precision) using characterized samples, and then validated with clinical samples.

    The analytical studies section describes using several panels for precision, reproducibility, and analytical sensitivity, which could be considered part of the development and optimization (training) process:

    • Precision panel: Five-member panel (4 dilutions of CT and GC, and a negative) tested with 6 replicates twice a day for 3 days at 3 sites.
    • Reproducibility panels: 30-member swab panels and 30-member urine panels (various seeded levels and unseeded samples) tested across 23 operators.
    • Analytical sensitivity: 15 C. trachomatis serovars and 39 N. gonorrhoeae strains diluted and assayed in triplicate.

    9. How the Ground Truth for the Training Set Was Established

    For the analytical studies that would contribute to establishing optimal parameters or "training" the assay:

    • Known Concentrations: Samples were prepared with known concentrations of C. trachomatis (EBs/rxn) and N. gonorrhoeae (cells/rxn) through serial dilutions of quantitated cultures. This provides a clear, quantitative ground truth.
    • Uninoculated Samples: Negative controls (sample diluent or unseeded samples) served as a known negative ground truth.
    • Known Strains/Serovars: Specific serovars of C. trachomatis and strains of N. gonorrhoeae were used, characterized by standard microbiological methods.
    Ask a Question

    Ask a specific question about this device

    K Number
    K981517

    Validate with FDA (Live)

    Date Cleared
    1998-06-09

    (42 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Use of BBL® Cefdinir Sensi-Discs® for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of bacteria to Cefdinir. Cefdinir has been shown to be active against most strains of microorganisms listed below, as described in the Parke-Davis package insert for this antimicrobic.

    Active In Vitro and In Clinical Infections Against:
    Aerobic Gram-Positive Microorganisms
    Staphylococcus aureus (including ß-lactamase producing strains, but excluding methicillin-resistant staphylococci) Streptococcus pneumoniae (penicillin-susceptible strains only) Streptococcus pvogenes
    Aerobic Gram-Neqative Microorganisms
    Haemophilus influenzae (including ß-lactamase producing strains) Haemophilus parainfluenzae (including ß-lactamase producing strains) Moraxella catarrhalis (including ß-lactamase producing strains)

    Active In Vitro Only Against:
    Aerobic Gram-Positive Microorganisms Staphylococcus epidermidis (methicillin-susceptible strains only) Streptococcus agalactiae Viridans group streptococci Aerobic Gram Negative Microorganisms Citrobacter diversus Escherichia coli Klebsiella pneumoniae Proteus mirabilis

    Device Description

    Antimicrobial Susceptibility Test Discs are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Cefdinir Sensi-Discs® are intended for use in determining the susceptibility to Cefdinir of a wide range of bacteria, as described under Indications For Use below. Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, Parke-Davis, a Division of Warner-Lambert Co., and received FDA approval under NDA Nos. 50-739 and 50-749.

    Cefdinir Susceptibility Test Discs are prepared by impregnating high quality paper with accurately determined amounts of Cefdinir supplied by the manufacturer. Parke-Davis. Each Cefdinir disc is clearly marked on both sides with the agent and content. Cefdinir discs are furnished in cartridges of 50 discs each. Cefdinir cartridges are packed as either a single cartridge in a single box, or in a package containing ten cartridges.

    Agar diffusion methods employing dried filter paper discs impregnated with specific concentrations of antimicrobial agents were developed in the 1940's. In order to eliminate or minimize variability in the testing, Bauer et al developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium.

    Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of these standardized procedures were those published by the U.S. Food and Drug Administration (FDA) and the World Health Organization (WHO). The procedure was adopted as a consensus standard by the National Committee for Clinical Laboratory Standards (NCCLS) and is periodically updated. The latest NCCLS documents are M2-A6 (1/97) and M100-S8 (1/98).

    Discs containing a wide variety of antimicrobial agents are applied to the surface of Mueller Hinton Agar plates [or Haemophilus Test Medium Agar for Haemophilus influenzae or Mueller Hinton Agar with 5% Sheep Blood for Streptococcus pneumoniae] inoculated with pure cultures of clinical isolates. Following incubation, the plates are examined and the zones of inhibition surrounding the discs are measured and compared with established zone size ranges for individual antimicrobial agents in order to determine the agent(s) most suitable for use in antimicrobial therapy. The determination as to whether the organism in question is susceptible (S), intermediate (I), or resistant (R) to an antimicrobial agent is made by comparing zone sizes to those found in the respective organism tables of National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A6 ("Performance Standards for Antimicrobial Disk Susceptibility Tests - Sixth Edition, Approved Standard", 1/97) and of NCCLS Document M100-S8 ("Performance Standards for Antimicrobial Susceptibility Testing", Eighth Informational Supplement, 1/98).

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the Cefdinir, 5 µg, Sensi-Discs:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategoryAcceptance Criteria (Implicit)Reported Device Performance (Summary)
    Performance StandardConformity to NCCLS standardsDemonstrated conformant performance based on interpretation of zone sizes against NCCLS M2-A6 and M100-S8.
    Zone Size InterpretationComparison to established rangesZone sizes are compared with established zone size ranges for individual antimicrobial agents to determine susceptibility.
    Control Organism LimitsWithin defined limitsControl organism limits determined by antimicrobic manufacturer (Parke-Davis) and received FDA approval.

    Note: The document itself does not explicitly list numerical acceptance criteria in a pass/fail format. Instead, it refers to industry-standardized procedures and interpretation guidelines. The "reported device performance" is essentially that the device functions according to these standards, allowing for accurate interpretation.

    2. Sample size used for the test set and the data provenance

    • Test Set Sample Size: Not explicitly stated. The document refers to "pure cultures of clinical isolates" but does not give a number.
    • Data Provenance: The document does not explicitly state the country of origin or if the data was retrospective or prospective. It refers to "clinical isolates," suggesting real-world samples.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not explicitly stated.
    • Qualifications of Experts: The ground truth for interpreting zone sizes and control organism limits was "determined by the antimicrobic manufacturer, Parke-Davis, a Division of Warner-Lambert Co., and received FDA approval" and by reference to "National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A6" and "NCCLS Document M100-S8." This implies that the standards themselves, developed by expert committees and validated by regulatory bodies, serve as the "ground truth establishment." There is no mention of individual experts reviewing the test set results.

    4. Adjudication method for the test set

    • Adjudication Method: Not applicable in the traditional sense of human consensus for individual test results. The device's performance is adjudicated against pre-established, standardized criteria (NCCLS documents and manufacturer-defined zone sizes/control limits). Interpretation of results involves comparing measured zone sizes to these established standards.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No. This device is an antimicrobial susceptibility test disc, a consumable used in a laboratory procedure. It does not involve AI or human "readers" in the context of image interpretation or diagnostic scanning for which MRMC studies are typically performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Standalone Performance: Not applicable in the context of an algorithm. The device itself is a physical disc. Its "standalone performance" is its ability to produce a measurable zone of inhibition when used according to standardized laboratory procedures. The interpretation of this zone into "susceptible," "intermediate," or "resistant" is a manual human step, guided by the NCCLS standards. There is no automated algorithm performing this interpretation described.

    7. The type of ground truth used

    • Type of Ground Truth: The primary ground truth is expert consensus/standardization as defined by the National Committee for Clinical Laboratory Standards (NCCLS) documents (M2-A6 and M100-S8) and manufacturer-established (Parke-Davis) zone size interpretation guidelines and control organism limits, which received FDA approval. This is essentially a standardized, accepted reference for what constitutes "susceptible," "intermediate," or "resistant."

    8. The sample size for the training set

    • Training Set Sample Size: Not applicable. This is not a machine learning or AI device that requires a "training set." The performance is based on chemical properties and standardized biological reactions, not statistical model training.

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set: Not applicable, as there is no training set for this type of device. The "ground truth" for the interpretation of the disc's results is established through the rigorous standardization process of the NCCLS and validation by the manufacturer and FDA.
    Ask a Question

    Ask a specific question about this device

    K Number
    K980683

    Validate with FDA (Live)

    Date Cleared
    1998-05-01

    (67 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Use of BBL Trovafloxacin Sensi-Discs® for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of bacteria to Trovafloxacin has been shown to be active against most strains of microorganisms listed below, as described in the Roerig package insert for this antimicrobic.

    Device Description

    Trovafloxacin Susceptibility Test Discs are prepared by impregnating high guality paper with accurately determined amounts of Trovafloxacin supplied by the manufacturer, Roerig. Each Trovafloxacin disc is clearly marked on both sides with the agent and content. Trovafloxacin discs are furnished in cartridges of 50 discs each. Trovafloxacin cartridges are packed as either a single cartridge in a single box, or in a package containing ten cartridges.

    Agar diffusion methods employing dried filter paper discs impregnated with specific concentrations of antimicrobial agents were developed in the 1940's. In order to eliminate or minimize variability in the testing, Bauer et al. developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium.

    Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of these standardized procedures were those published by the U.S. Food and Drug Administration (FDA) and the World Health Organization (WHO). The procedure was adopted as a consensus standard by the National Committee for Clinical Laboratory Standards (NCCLS) and is periodically updated. The latest NCCLS documents are M2-A6 (1/97) and M100-S7 (1/97).

    Discs containing a wide variety of antimicrobial agents are applied to the surface of Mueller Hinton Agar plates {or Haemophilus Test Medium Agar for Haemophilus influenzae or Mueller Hinton Aqar with 5% Sheep Blood for Streptococcus pneumoniae] inoculated with pure cultures of clinical isolates. Following incubation, the plates are examined and the zones of inhibition surrounding the discs are measured and compared with established zone size ranges for individual antimicrobial agents in order to determine the agent(s) most suitable for use in antimicrobial therapy. The determination as to whether the organism in question is susceptible (S), intermediate (I), or resistant (R) to an antimicrobial agent is made by comparing zone sizes to those found in the respective organism tables of National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A6 ("Performance Standards for Antimicrobial Disk Susceptibility tests - Sixth Edition, Approved Standard", 1/97) and of NCCLS Document M100-S8 ("Performance Standards for Antimicrobial Susceptibility Testing", Eighth Informational Supplement, 1/98).

    AI/ML Overview

    Based on the provided text, here's an analysis of the acceptance criteria and study information for the Trovafloxacin Sensi-Discs:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't explicitly state "acceptance criteria" in a quantitative, pass/fail table format that is typical for modern device submissions. Instead, it relies on alignment with established industry standards for antimicrobial susceptibility testing. The accepted performance is essentially defined by adherence to these standards and the established zone size ranges for Trovafloxacin.

    Performance Metric/CriteriaReported Device Performance
    Zone Sizes for InterpretationZone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, Roerig, a Division of Pfizer Inc., and received FDA approval under NDA Nos. 20-759 and 20-760. The determination as to whether the organism in question is susceptible (S), intermediate (I), or resistant (R) is made by comparing zone sizes to those found in the respective organism tables of National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A6 ("Performance Standards for Antimicrobial Disk Susceptibility tests - Sixth Edition, Approved Standard", 1/97) and NCCLS Document M100-S8 ("Performance Standards for Antimicrobial Susceptibility Testing", Eighth Informational Supplement, 1/98).
    Standardized Test Procedure AdherenceThe device performance implicitly meets the acceptance criteria by conforming to standardized agar diffusion test procedures, specifically those based on the Bauer-Kirby method as adopted by the National Committee for Clinical Laboratory Standards (NCCLS), and documented in M2-A6 (1/97) and M100-S7 (1/97) and M100-S8 (1/98).
    Activity against specified microorganisms (In Vitro and In Clinical Infections)Demonstrated activity against the list of microorganisms provided (e.g., Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, Haemophilus influenzae, Bacteroides fragilis, Chlamydia pneumoniae, etc.) as described in the Roerig package insert for Trovafloxacin.
    Activity against specified microorganisms (In Vitro Only)Demonstrated activity against the list of microorganisms provided for in vitro only (e.g., penicillin-resistant Streptococcus pneumoniae, Citrobacter freundii, Bacteroides distasonis, Mycoplasma hominis, etc.) as described in the Roerig package insert for Trovafloxacin.
    Product Manufacturing Quality (e.g., accurate amounts of Trovafloxacin, clear marking)"Trovafloxacin Susceptibility Test Discs are prepared by impregnating high quality paper with accurately determined amounts of Trovafloxacin supplied by the manufacturer, Roerig. Each Trovafloxacin disc is clearly marked on both sides with the agent and content." (This is a description of the product and implicitly a quality criterion).

    2. Sample Size Used for the Test Set and Data Provenance:

    The document refers to "Performance Data: See attached Roerig product insert section on Susceptibility Tests - Diffusion Techniques for TROVAN™ Tablets (trovafloxacin mesylate tablets) and TROVAN™ I.V. (alatrofloxacin mesylate injection) for intravenous infusion."

    • Sample Size: The specific sample size for the test set is not provided in the excerpt. It defers to the Roerig product insert, which is not included.
    • Data Provenance: The document does not specify the country of origin of the data. It seems to refer to data generated by Roerig (a division of Pfizer Inc.), which is a pharmaceutical company. The type of data would be related to clinical trials and in vitro susceptibility testing that formed the basis for the drug's FDA approval (NDA Nos. 20-759 and 20-760). This would implicitly be prospective data collected during the drug's development.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of those Experts:

    This information is not explicitly provided in the excerpt. The ground truth for antimicrobial susceptibility testing, especially for establishing zone size breakpoints, is typically determined through extensive in vitro and in vivo correlation studies, pharmacokinetic/pharmacodynamic modeling, and epidemiological cutoff values. This process involves numerous clinical microbiologists, pharmacologists, and infectious disease specialists, but their specific number and qualifications are not detailed for this submission. The document states that the zone sizes and control organism limits "were determined by the antimicrobic manufacturer, Roerig... and received FDA approval." This implies expert consensus and rigorous review by regulatory bodies.

    4. Adjudication Method for the Test Set:

    The document does not describe any adjudication method. For antimicrobial susceptibility testing, the "ground truth" (i.e., whether an organism is S, I, or R to an agent) is established by comparing measured zone sizes to predetermined interpretive criteria (breakpoints) set by standardized bodies like the NCCLS, which are themselves derived from extensive studies. It's not a subjective interpretation requiring adjudication in the way medical imaging might.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done:

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done or described. This type of study is highly relevant for subjective diagnostic interpretations (e.g., AI in radiology). Here, the device is a disc for in vitro laboratory testing, not a diagnostic imaging AI. The "readers" are laboratory technicians measuring zone diameters, which is a relatively objective measurement compared to interpreting complex clinical images.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done:

    The device itself (Trovafloxacin Sensi-Discs) is not an "algorithm" in the AI sense. It's a consumable product used in a manual laboratory procedure.

    However, the "performance data" referred to in the Roerig product insert would represent the standalone performance of the antimicrobial agent (Trovafloxacin) in determining susceptibility, based on the established zone size breakpoints. This is a form of standalone performance in that it evaluates the accuracy of the drug's activity and the interpretive criteria, independent of the specific disc manufacturer, as long as the disc meets quality standards (e.g., accurate drug concentration).

    7. The Type of Ground Truth Used:

    The ground truth used is primarily expert consensus based on extensive in vitro (microbiological) and in vivo (clinical outcomes) correlation data, pharmacokinetic/pharmacodynamic studies, and epidemiological cutoff values. This is distilled into the standardized interpretive criteria (zone size breakpoints) published by organizations like the NCCLS and approved by the FDA (as indicated by the references to NDA approvals for the drug itself). The product relies on the established validity of these breakpoints.

    8. The Sample Size for the Training Set:

    This information is not provided in the excerpt. The concept of a "training set" in the context of machine learning doesn't directly apply to this device. For the drug itself (Trovafloxacin), the data used to establish its activity profile and breakpoints would have involved a very large number of microbial isolates tested in vitro and patients treated in vivo.

    9. How the Ground Truth for the Training Set Was Established:

    Similar to point 8, the concept of a "training set" ground truth is not directly applicable. However, for the underlying interpretive breakpoints, the ground truth was established through:

    • Clinical Efficacy Studies: For the drug Trovafloxacin, its efficacy against various microorganisms would have been established through clinical trials (human outcomes data).
    • Microbiological Studies: Extensive in vitro testing of thousands of bacterial isolates to determine Minimum Inhibitory Concentrations (MICs) and correlate them with zone diameters.
    • Pharmacokinetic/Pharmacodynamic (PK/PD) Modeling: Studies to understand how the drug behaves in the human body and how its concentration correlates with bacterial killing.
    • Expert Panels: Review and approval by expert committees (e.g., NCCLS, FDA) who synthesize all available data to set the final interpretive criteria (susceptible, intermediate, resistant breakpoints).
    Ask a Question

    Ask a specific question about this device

    K Number
    K974578

    Validate with FDA (Live)

    Date Cleared
    1998-02-23

    (77 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Antimicrobial Susceptibility Test Discs are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Grepafloxacin Sensi-Discs® are intended for use in determining the susceptibility to Grepafloxacin of a wide range of bacteria, including Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus agalactiae, Streptococcus pneumoniae. Streptococcus pyogenes, Citrobacter freundii, Citrobacter (diversus) koseri, Enterobacter aerogenes, Enterobacter cloacae,, Escherichia coli, Haemophilus parainfluenzae, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, and Proteus vulgaris. Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, GlaxoWellcome, Inc., and received FDA approval under NDA No. 50-717.

    Use of BBL® Grepafloxacin Sensi-Discs® for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of bacteria to Grepafloxacin.

    Grepafloxacin has been shown to be active against most strains of microorganisms listed below, both in vitro and in clinical infections, as described in the GlaxoWellcome, Inc., package insert for this antimicrobic.

    Aerobic Gram-Positive Microorganisms

    Streptococcus pneumoniae (penicillin-susceptible strains) Aerobic Gram-Negative Microorganisms

    Haemophilus influenzae Moraxella catarrhalis Neisseria gonorrhoeae Other microorganisms Chlamydia trachomatis Mycoplasma pneumoniae

    Grepafloxacin exhibits in vitro minimum inhibitory concentrations (MICs) of 1 ug/ml or less against most (≥90%) strains of the microorganisms listed below: however, the safety and effectiveness of Grepafloxacin in treating clinical infections due to these microorganisms have not been established in adequate and well-controlled clinical trials.

    Aerobic Gram-Positive Microorganisms (/n Vitro Only)

    Staphylococcus aureus (methicillin-susceptible strains) Staphylococcus epidermidis (methicillin-susceptible strains) Streptococcus agalactiae Streptococcus pneumoniae (penicillin-resistant strains) Streptococcus pyogenes

    Aerobic Gram-Negative Microorganisms (/n Vitro Only)

    Citrobacter freundii Citrobacter (diversus) koseri Enterobacter aerogenes Enterobacter cloacae Escherichia coli Haemophilus parainfluenzae Klebsiella oxytoca Klebsiella pneumoniae Morganella morganii Proteus mirabilis Proteus vulgaris

    Device Description

    Antimicrobial Susceptibility Test Discs are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Grepafloxacin Sensi-Discs® are intended for use in determining the susceptibility to Grepafloxacin of a wide range of bacteria, including Staphylococcus aureus, Staphylococcus epidermidis. Streptococcus agalactiae, Streptococcus pneumoniae, Streptococcus pyogenes, Citrobacter freundii, Citrobacter (diversus) koseri, Enterobacter aerogenes, Enterobacter cloacae,, Escherichia coli, Haemophilus parainfluenzae, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, and Proteus vulgaris. Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, GlaxoWellcome, Inc., and received FDA approval under NDA No. 50-717.

    Grepafloxacin Susceptibility Test Discs are prepared by impregnating high quality paper with accurately determined amounts of Grepafloxacin supplied by the manufacturer, GlaxoWellcome, Inc., Research Triangle Park, North Carolina. Each Grepafloxacin disc is clearly marked on both sides with the agent and content. Grepafloxacin discs are furnished in cartridges of 50 discs each. Grepafloxacin cartridges are packed as either a single cartridge in a single box, or in a package containing ten cartridges.

    Agar diffusion methods employing dried filter paper discs impregnated with specific concentrations of antimicrobial agents were developed in the 1940's. In order to eliminate or minimize variability in the testing, Bauer et al, developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium.

    Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of these standardized procedures were those published by the U.S. Food and Drug Administration (FDA) and the World Health Organization (WHO). The procedure was adopted as a consensus standard by the National Committee for Clinical Laboratory Standards (NCCLS) and is periodically updated. The latest NCCLS documents are M2-A6 (1/97) and M100-S7 (1/97).

    Discs containing a wide variety of antimicrobial agents are applied to the surface of Mueller Hinton Agar plates for Haemophilus Test Medium Agar for Haemophilus influenzae or Mueller Hinton Agar with 5% Sheep Blood for Streptococcus pneumoniae] inoculated with pure cultures of clinical isolates. Following incubation, the plates are examined and the zones of inhibition surrounding the discs are measured and compared with established zone size ranges for individual antimicrobial agents in order to determine the agent(s) most suitable for use in antimicrobial therapy. The determination as to whether the organism in question is susceptible (S), intermediate (I), or resistant (R) to an antimicrobial agent is made by comparing zone sizes to those found in the respective organism tables of National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A6 ("Performance Standards for Antimicrobial Disk Susceptibility tests - Sixth Edition, Approved Standard", 1/97) and of NCCLS Document M100-S7 ("Performance Standards for Antimicrobial Susceptibility Testing", Seventh Informational Supplement. 1/97).

    AI/ML Overview

    This document describes the Grepafloxacin, 5 mcg, Sensi-Discs, an antimicrobial susceptibility test device. The information provided heavily references an attached product insert for RAXAR™ Tablets (grepafloxacin hydrochloride tablets) from GlaxoWellcome, Inc. However, this specific submission (K974578) from Becton Dickinson Microbiology Systems does not contain the detailed performance data or acceptance criteria that would typically be found in a study report proving the device meets those criteria.

    The submission primarily focuses on the device description, intended use, indications for use, and a declaration of substantial equivalence to a predicate device. It states that "Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, GlaxoWellcome, Inc., and received FDA approval under NDA No. 50-717." It also references NCCLS documents M2-A6 and M100-S7 for interpretation.

    Therefore, many of the requested details about the study are not present in the provided text.

    Based on the available information:

    1. Table of acceptance criteria and the reported device performance:

    The document states that zone sizes and control organism limits "were determined by the antimicrobic manufacturer, GlaxoWellcome, Inc., and received FDA approval under NDA No. 50-717." However, the specific quantitative acceptance criteria (e.g., accuracy percentages, major error rates) and reported device performance against these criteria are not provided in this submission. The submission refers to an attached GlaxoWellcome, Inc., product insert, which is not included in the provided text.

    Acceptance CriteriaReported Device Performance
    Not specified in this document; referenced in GlaxoWellcome, Inc. product insert and NCCLS documents M2-A6 and M100-S7.Not specified in this document; referenced in GlaxoWellcome, Inc. product insert.

    2. Sample size used for the test set and the data provenance:

    • Sample size: Not specified in the provided text. The submission mentions "clinical isolates" but gives no specific numbers.
    • Data provenance: Not specified in the provided text. The testing procedures mentioned (Bauer-Kirby method, Mueller Hinton Agar) are standard laboratory practices, implying lab-generated data, but details on country of origin or whether it was retrospective/prospective are absent.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    Not specified in the provided text. The ground truth would typically be established by comparing the disc diffusion results to a reference method like broth microdilution Minimum Inhibitory Concentration (MIC) testing. The involvement and qualifications of experts for this comparison are not mentioned.

    4. Adjudication method for the test set:

    Not specified in the provided text.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This is a medical device for in vitro susceptibility testing (disc diffusion), not an AI-powered diagnostic device involving human readers for interpretation. The interpretation is based on measuring zones of inhibition and comparing them to established breakpoints.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This device is a physical disc impregnated with an antimicrobial agent, used in a traditional laboratory procedure. There is no "algorithm only" performance as it requires human setup, inoculation, incubation, and measurement of inhibition zones.

    7. The type of ground truth used:

    The ground truth for antimicrobial susceptibility testing is typically established by Minimum Inhibitory Concentration (MIC) values determined by a reference method (e.g., broth microdilution). The document mentions that "Grepafloxacin exhibits in vitro minimum inhibitory concentrations (MICs) of 1 ug/ml or less against most (≥90%) strains of the microorganisms listed below," implying MICs were used as a reference.

    8. The sample size for the training set:

    Not specified in the provided text. This type of device does not typically involve a "training set" in the context of machine learning. If this refers to the data used to initially establish the zone size breakpoints, those were determined by GlaxoWellcome, Inc., but the sample size is not stated here.

    9. How the ground truth for the training set was established:

    Not specified in the provided text. The document refers to the antimicrobic manufacturer, GlaxoWellcome, Inc., for the determination of zone sizes and interpretation, which would have been based on correlation with MIC data (the ground truth).

    Ask a Question

    Ask a specific question about this device

    K Number
    K970333

    Validate with FDA (Live)

    Date Cleared
    1998-01-28

    (365 days)

    Product Code
    Regulation Number
    866.2560
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BACTEC® MYCO/F Lytic culture vials when used with the 9000 Blood Culture series of instrumentation are intended as an adjunct to routine blood culture for patients suspected of having mycobacteria, yeast and fungi septicemia. Extended incubation times (7 days for yeast, 30 days for fungi, and 42 days for mycobacteria) will permit recovery of mycobacteria and fungi when more rapidly growing organisms are not present. This medium may also be used for the culture of sterile body fluids when yeast or fungi are suspected.

    Device Description

    BACTEC MYCO/F LYTIC Culture medium is a Middlebrook 7H9 and Brain Heart Infusion broth formulation for the recovery of mycobacteria from blood specimens and fungi from blood and sterile body fluids. The range of specimen volume which can be cultured is one to five mL. with optimum recovery obtained at three to five mL. Specific modifications were made to enhance the growth and recovery of mycobacteria, veast, and fungi. These modifications include ferric ammonium citrate to provide an iron source for specific strains of mycobacteria and fungi, the addition of saponin as a blood lysing agent and the addition of specific proteins and sugars to provide nutritional supplements. Each vial contains a sensor which can detect decreases in oxygen concentration in the vial resulting from microorganism and growth. The sensor is monitored by the BACTEC 9000 Blood Culture Systems for increasing fluorescence which is proportional to the decrease in oxygen. A positive determination indicates the presumptive presence of viable microorganisms in the vial.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    Acceptance Criteria and Device Performance

    The BACTEC MYCO/F LYTIC Blood Culture Medium is deemed substantially equivalent to predicate devices (BACTEC 13A for mycobacteria and BACTEC NR FUNGAL for yeast/fungi) based on internal and clinical studies demonstrating "equivalent performance." While explicit numerical acceptance criteria for recovery rates or time to detection are not provided as fixed thresholds, the studies aim to show that the new device performs comparably or better than the predicate devices across various clinically relevant scenarios.

    Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance Criteria (Implied by Substantial Equivalence Goal)Reported Device Performance (BACTEC MYCO/F LYTIC)Predicate Device Performance (BACTEC 13A / BACTEC NR FUNGAL)Notes
    Recovery of Mycobacteria (Clinical)Equivalent or improved recovery compared to BACTEC 13A.10 (9%) isolates recovered only by Myco/F Lytic.3 (3%) isolates recovered only by BACTEC 13A.Myco/F Lytic demonstrated improved unique recovery for mycobacteria. Total 111 pathogenic mycobacteria isolates.
    Recovery of Yeast & Fungi (Clinical)Equivalent or improved recovery compared to ISOLATOR™ System.7 (22%) isolates recovered only by Myco/F Lytic.6 (19%) isolates recovered only by ISOLATOR™ System.Myco/F Lytic demonstrated slightly improved unique recovery for yeast/fungi. Total 32 pathogenic yeast/fungal isolates.
    Recovery of Yeast & Fungi (Internal)Equivalent recovery and time to detection (TTD) compared to BACTEC NR FUNGAL.Improved recovery of Histoplasma capsulatum and Malesezzia furfur. Equivalent for various Candida and Cryptococcus species. Not detectable for Penicillium purpurescens and Blastomyces dermatitidis. Inconsistent for Hansenula anomala, Exophiala jeanseimelei, Actinomyces bovis, Rhodotorula rubra, Mucor ramosissimus at low inoculum.(See Table 2 for detailed TTD)Mixed results depending on the specific organism and inoculum level. The phrase "equivalent performance" might be an overarching claim, with noted exceptions.
    Recovery of Mycobacteria (Internal)Acceptable recovery and TTD compared to BACTEC 13A (implicitly).Acceptable for a majority of tested species. Detection delays/compromised recovery for M. intracellulare, M. malmoense, M. haemophilum, M. xenopi with < 3 mL blood.(See Table 3 for detailed TTD)Generally acceptable, with specific limitations noted for low blood volumes.
    False Positive Rate (Clinical)Acceptable rate for a blood culture system (no explicit number given).0.7% (11 out of 1,488 blood cultures)Not directly compared to a predicate here.Within expected range for such systems at the time.
    False Negative Rate (Clinical)Acceptable rate for a blood culture system (no explicit number given).0.07% (1 out of 1,488 blood cultures)Not directly compared to a predicate here.Within expected range for such systems at the time.
    Contamination Rate (Clinical)Acceptable rate for a blood culture system (no explicit number given).3.3%Not directly compared to a predicate here.Within expected range for such systems at the time.

    Study Details

    2. Sample sizes used for the test set and the data provenance:

    • Clinical Studies (Test Set):
      • Mycobacteria: 1,100 blood culture specimens.
      • Yeast and Fungi (Blood): 748 blood culture specimens.
      • Overall Clinical Evaluation (Mycobacteria, Yeast, Fungi, Other Bacteria): 1,488 blood cultures.
    • Internal Performance Studies (Test Set - In Vitro):
      • Yeast and Fungi: A variety of species at different CFU levels (e.g., TNTC, 170, 16, 80, 6 CFU/vial) and specimen volumes (0 mL, 1 mL, 5 mL blood). Each value is the average of "all vials per test condition" (specific number of vials per condition not detailed).
      • Mycobacteria: A variety of species at different CFU levels (e.g., 0, 1, 2, 3, 5, 7, 12, 13, 16, 20, 31, 44, 45, 49, 53, 58, 68 CFU/vial) and specimen volumes (1 mL, 3 mL, 5 mL blood). Two replicates ("Replicate" and original reading) are shown for each condition.
    • Data Provenance:
      • Clinical Studies: Conducted at "two clinical sites considered large tertiary care teaching hospitals in geographically diverse areas" (for mycobacteria) and "four clinical sites considered large tertiary care teaching hospitals" (for fungi). Patient populations included HIV, immunocompromised, transplant patients, and those suspected of mycobacterial or fungal infections. This indicates prospective clinical data from diverse, real-world patient samples.
      • Internal Performance Studies: Conducted by Becton Dickinson Microbiology Systems. These are retrospective/in-vitro laboratory studies using controlled inoculums of specific organism strains.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    The document does not explicitly state the number of experts or their specific qualifications (e.g., radiologists with X years of experience). However, for the clinical studies, ground truth was established by:

    • Determining the "total number of pathogenic mycobacteria isolates recovered" and "total number of pathogenic yeast and fungal isolates recovered" from the various culture media.
    • For false positive/negative rates, instrument results were compared to "smear and/or subculture-negative" or "smear and/or subculture-positive." This implies standard microbiological techniques and interpretation by laboratory professionals, rather than image interpretation by radiologists.

    4. Adjudication method for the test set:

    The document does not describe a formal adjudication method (like 2+1 or 3+1). The ground truth for the clinical studies appears to be based on the established clinical laboratory results from the two or four tertiary care hospitals involved, likely following standard diagnostic protocols of the time. For false positives/negatives, smear and/or subculture results served as the determinant.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This is not applicable to this device. The BACTEC MYCO/F LYTIC system is a blood culture medium used with an automated instrument for microbial growth detection, not an AI-assisted diagnostic imaging device that involves "human readers" in the traditional sense of image interpretation. The comparison is between different culture media/systems and their ability to recover and detect microorganisms.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    The BACTEC MYCO/F LYTIC is a culture medium used with an instrument (BACTEC 9000 Blood Culture Series). The instrument automates the detection of growth (based on oxygen metabolism), but the "algorithm only" concept usually refers to AI in image analysis or similar fields. The performance measured is that of the medium and instrument system in detecting growth. While automated, human intervention is still required for specimen collection, inoculation, and interpretation of positive results (e.g., Gram stain, subculture for identification). Therefore, it's a device-only performance rather than a standalone algorithm in the AI sense.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • Clinical Studies: Ground truth was established by microbiological culture results from the comparative methods (BACTEC 13A, ISOLATOR™ System) and confirmed by subculture and/or smear for positive/negative determinations. For identifying pathogenic isolates, standard laboratory identification methods would have been used.
    • Internal Performance Studies: Ground truth was established by known inoculum levels of specific microbial strains (CFU/vial) in a controlled laboratory setting.

    8. The sample size for the training set:

    • The document does not explicitly describe a "training set" in the context of machine learning. The studies are traditional clinical and internal performance evaluations demonstrating the device's efficacy and substantial equivalence.
    • The "Substantial Equivalence" section mentions "Internal and clinical studies demonstrated equivalent performance with all predicate devices," implying these studies were used to demonstrate performance rather than to "train" an algorithm.

    9. How the ground truth for the training set was established:

    • As there's no explicitly defined "training set" in the AI/ML context, this question is not applicable in the sense of how an algorithm's ground truth was established by experts for training.
    • The "ground truth" for the overall evaluation involves the known presence/absence of microorganisms and their identification through standard microbiological laboratory procedures and controlled laboratory inoculations, as described in point 7.
    Ask a Question

    Ask a specific question about this device

    K Number
    K970512

    Validate with FDA (Live)

    Date Cleared
    1998-01-08

    (331 days)

    Product Code
    Regulation Number
    866.2560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BACTEC ® MYCO/F LYTIC Culture vial when used with the BACTEC 9000MB System is a qualitative test for the culture and recovery of mycobacteria in human blood speciments from patients who are suspected of having septicemia.

    Device Description

    BACTEC MYCO/F LYTIC blood culture medium is a non-selective growth medium intended for the culture and recovery of mycobacteria and designed for blood volumes of one to five mL. BACTEC MYCO/F LYTIC culture medium is a Middlebrook 7H9 and Brain Heart Infiusion broth formulation with specific formulation modifications made to enhance the growth of mycobacteria. It is used specifically with the BACTEC 9000MB instrument in the monitoring of clinical blood specimens for the presence of microorganisms. This medium contains the same fluorescence senor as the BACTEC MYCO/F Sputa culture medium and detection is based on changes in oxygen concentration in the vial resulting from metabolism and growth of microorganisms. The sensor is monitored by the BACTEC 9000MB System for increasing fluorescence which is proportinal to the decrease in oxygen. A positive determination indicates the presumptive presence of viable microorganisms in the vial.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study details for the BACTEC MYCO/F LYTIC Culture Medium, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly define formal "acceptance criteria" with specific thresholds (e.g., "sensitivity must be >X%"). However, it implies acceptance criteria by comparing the performance of the BACTEC MYCO/F LYTIC medium to a predicate device (BACTEC 13A) and by reporting internal performance characteristics.

    The implied objective is that the BACTEC MYCO/F LYTIC medium should be at least comparable to, or ideally better than, the predicate device in terms of mycobacteria recovery and detection, with acceptable false positive and false negative rates.

    Since explicit acceptance criteria are missing as numerical targets, I will present the key performance metrics reported in the studies.

    Performance MetricAcceptance Criteria (Implied)Reported Device Performance (BACTEC MYCO/F LYTIC)
    Clinical Recovery (Overall)Comparable or improved recovery of pathogenic mycobacteria compared to BACTEC 13A.Total 39 pathogenic mycobacterial isolates recovered. 5 (13%) recovered ONLY in BACTEC MYCO/F LYTIC. 2 (5%) recovered ONLY by BACTEC 13A. 32 recovered by both.
    Clinical Recovery (Species-specific)Demonstrate recovery of various pathogenic mycobacteria species.Mycobacterium avium: 3/30 recovered only by MYCO/F LYTIC, 1/30 only by 13A, 26 by both. Mycobacterium tuberculosis: 6/6 recovered by both. Mycobacterium kansasii: 2/3 recovered only by MYCO/F LYTIC, 1/3 only by 13A.
    Internal Recovery (Species Diversity)Detect a variety of mycobacteria species as positive.Detected: M. tuberculosis, M. kansasii, M. fortuitum, M. intracellulare, M. bovis, M. terrae, M. simiae, M gordonae, M. celatum, M. abscessus, M. maimoense. Unsatisfactory recovery: M. xenopi and M. szulgai.
    False Positive RateAcceptably low false positive rate. (No explicit numerical threshold given, but generally, lower is better).0.4% (1 out of 284 blood specimens). For instrument positive MYCO/F LYTIC vials: 2.6% (1 out of 38). (Note: 16 false positives out of 28 overfilled vials were excluded from the study due to protocol deviation).
    False Negative RateAcceptably low false negative rate. (No explicit numerical threshold given).0% (Based on terminal subcultures of 50% of negative vials).
    Contamination RateAcceptably low contamination rate. (No explicit numerical threshold given).0.9%
    Time to Detection (Internal Study)General indication of detection within a reasonable timeframe (implied, not explicitly quantified as a criterion for clinical relevance).Varies by species and blood volume. Examples: M. tuberculosis avg 22.9 days (1 mL), 18.7 (3 mL), 17.3 (5 mL). M. avium avg 8.0-8.1 days. M. fortuitum avg 8.0-5.1 days. (See Table 2 for full details).

    2. Sample Size and Data Provenance

    • Clinical Test Set Sample Size: 284 blood specimens.
    • Data Provenance: Prospective clinical study conducted at "two clinical sites considered large tertiary care teaching hospitals in geographically diverse areas." The specific country of origin is not mentioned but typically for FDA submissions of this era, the studies would be conducted in the United States.

    3. Number of Experts and Qualifications for Ground Truth

    The document does not explicitly state the number of experts or their specific qualifications for establishing the "ground truth" (e.g., "smear and/or subculture-negative/positive") for the clinical test set. It mentions "microbiological workup" and validation against "smear and/or subculture." This implies standard laboratory practices performed by qualified laboratory personnel, but details on expertise (e.g., years of experience, specific certifications) are absent.

    4. Adjudication Method

    The document does not describe an explicit adjudication method (like 2+1 or 3+1) for resolving discrepancies in the ground truth for the clinical test set. The ground truth ("smear and/or subculture-negative/positive") appears to be determined by confirmed laboratory results.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not conducted. This study compares a device (the BACTEC MYCO/F LYTIC medium) directly against a predicate device (BACTEC 13A medium) in a clinical evaluation, but it is not a "human reader" study; it's a comparison of culture media performance. Therefore, an effect size of human readers improving with or without AI assistance is not applicable.

    6. Standalone (Algorithm Only) Performance Study

    Yes, a standalone performance study was conducted. The "INTERNAL PERFORMANCE" section and "Table 2: Detection of Mycobacteria in the Myco/F Lytic Medium" represent a standalone evaluation. This study assessed the recovery and time to detection of various mycobacteria species at different CFU levels specifically with the BACTEC MYCO/F LYTIC medium and the BACTEC 9000MB instrument, without direct comparison to human reading or other media as the primary objective.

    7. Type of Ground Truth Used

    • Clinical Study: The ground truth for the clinical performance evaluation was established through laboratory confirmation (smear and/or subculture results). This represents definitive microbiological results, which would fall under a form of "pathology" in a broader sense of laboratory diagnostics.
    • Internal Study: The ground truth for the internal performance study (Table 2) was based on known mycobacteria strains and quantified CFU/bottle (Colony Forming Units per bottle), with the outcome being the time to detection by the BACTEC 9000MB instrument.

    8. Sample Size for the Training Set

    The document does not mention a training set for the BACTEC MYCO/F LYTIC culture medium. This type of device (a culture medium for microbial growth detection) does not typically involve machine learning algorithms that require explicit "training sets" in the conventional sense. The "internal performance" study (Table 2) could be considered an initial validation or characterization of the medium's performance with known isolates under controlled conditions, serving a similar purpose to testing the device's inherent capabilities before clinical evaluation.

    9. How the Ground Truth for the Training Set Was Established

    Since there is no explicit mention of a "training set" in the context of machine learning, this question is not directly applicable. If the "internal performance" study is considered a foundational or characterization study, the ground truth was established by using known, cultured mycobacteria strains with quantified concentrations (CFU/bottle).

    Ask a Question

    Ask a specific question about this device

    K Number
    K972758

    Validate with FDA (Live)

    Date Cleared
    1997-08-08

    (53 days)

    Product Code
    Regulation Number
    866.2560
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MYCO/F-Sputa culture media BACTEC Supplement /F when used with the BACTEC Brand 9000MB fluorescent series instrument is a qualitative procedure for the in vitro culture and recovery of mycobacteria from digested decontaminated clinical specimens and sterile body fluids other than blood.

    MYCO/F-Sputa culture media with the addition of BACTEC Supplement/F when used with the BACTEC Brand 9000MB fluorescent series instrument is a qualitative test for the in-vitro culture and recovery of mycobacteria from digested decontaminated clinical specimens and sterile body fluids other than blood from patients suspected of pulmonary or disseminated mycobacterial infection.

    Device Description

    BACTEC® MYCO/F-Sputa Culture Vials containing 7H9 Middlebrook broth base with nutrient additives and antimicrobial supplement (Polymyxin B, amphotericin B, nalidixic acid, trimethoprim & azlocillin (PANTA)). Growth detection is by fluorescent detection of O₂ consumption by mycobacterial growth using the BACTEC® 9000MB automated system.

    AI/ML Overview

    Here's the analysis of the provided text regarding the BACTEC® MYCO/F-Sputa Culture Vials, structured according to your request:

    Acceptance Criteria and Study Performance for BACTEC® MYCO/F-Sputa Culture Vials

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly defined by comparing the new device against two predicate devices: BACTEC 12B Culture Vials (using the BACTEC 460TB system) and Conventional Media (Lowenstein-Jensen agar slants). The study aims to demonstrate "equivalence of mycobacterial growth detection methods".

    Acceptance Criterion (Implicit)Predicate 1: BACTEC 460TB SystemPredicate 2: Conventional Media (Lowenstein-Jensen)BACTEC® MYCO/F-Sputa Culture Vials PerformanceDevice Meets Criterion?
    Time to Detection (Overall All Isolates)13.3 days24.3 days12.2 daysYes (No significant difference vs. BACTEC 460TB, statistically significantly faster than Conventional Media)
    Time to Detection (MTB Complex)17.2 days22.1 days18.4 daysYes
    Time to Detection (M Avium Complex)10.2 days28.3 days7.9 daysYes
    Mycobacterial Recovery (Pathogenic Isolates)30 (78.9%) of 38 total24 (63.2%) of 38 total29 (76.3%) of 38 totalYes (No statistical difference vs. either predicate)
    Combined Recovery (New Device + Conventional Media)Not applicableNot applicable89.5% of total pathogenic isolatesN/A (reported, but not a direct comparison for equivalence)
    False Positive RateNot explicitly stated for predicates, but generally accepted to be low for equivalent predicate systemsNot explicitly stated, but generally accepted to be low for equivalent predicate systems5.0% (Overall for the BACTEC 9000MB system)Yes (Reported, and context implies acceptance despite variation from respiratory specimens)
    Breakthrough Contamination Rate (Norm. Sterile Specimens)Not explicitly stated for predicatesNot explicitly stated for predicates4.7% - 18.9%Yes (Reported, acceptance implied through clearance)
    Breakthrough Contamination Rate (Non-sterile Specimens)Not explicitly stated for predicatesNot explicitly stated for predicates8.2% - 73.9%Yes (Reported, acceptance implied through clearance)
    Overall Breakthrough Contamination RateNot explicitly stated for predicatesNot explicitly stated for predicates14.9%Yes (Reported, acceptance implied through clearance)

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size:
      • Time to Detection Study: The document mentions "Paired t-tests were performed to compare time to detection...". It does not explicitly state the total number of positive cultures included in these specific analyses, but it does provide overall average detection times.
      • Recovery Performance Study: 803 non-respiratory specimens were tested. From these, 38 pathogenic mycobacteria positive isolates were recovered.
    • Data Provenance: The recovery performance study was conducted "at a large tertiary care teaching hospital". This suggests a real-world clinical setting. The document does not specify the country of origin, but given the FDA 510(k) submission, it is highly likely to be U.S.-based. The study appears to be prospective in nature, as it describes a controlled comparison of testing methods on collected specimens.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    The document does not specify the number of experts or their qualifications for establishing the ground truth. However, for mycobacterial culture and identification, ground truth is typically established by:

    • Standard microbiological culture techniques and subsequent identification methods (e.g., biochemical tests, genetic probes).
    • Clinician's diagnosis and patient outcomes.

    Given the context of an in vitro diagnostic device for culture and recovery, the "ground truth" for recovery and time to detection would be based on the established gold standard methods for mycobacterial identification. It's implied that the results from the predicate devices (BACTEC 460TB and Conventional Media) served as reference points or "ground truth comparators" for the new device.

    4. Adjudication Method for the Test Set

    The document does not describe a formal "adjudication method" in the sense of multiple independent reviewers resolving discrepancies. The comparison is between the performance metrics of the BACTEC MYCO/F-Sputa culture vials and the predicate devices (BACTEC 12B and Conventional Media). Statistical tests (paired t-tests and McNemar's paired comparison) were used to determine the significance of observed differences, which is a form of objective comparison rather than expert adjudication of individual case disagreement.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size of Human Readers Improvement with AI vs. Without AI Assistance

    This question is not applicable. The device described (BACTEC® MYCO/F-Sputa Culture Vials) is an in vitro diagnostic device for laboratory use to detect microbial growth. It is not an AI-assisted diagnostic tool that directly aids human readers in interpreting medical images or other complex data. Therefore, an MRMC study and effects on human reader performance with AI assistance are outside the scope of this device.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, the studies described are essentially "standalone" performance evaluations of the device. The BACTEC® 9000MB system automates the incubation, agitation, and fluorescent detection of oxygen consumption, indicating mycobacterial growth. The reported time to detection and recovery rates are inherent to the device and system, operating without direct human interpretation of a reading (other than setting up the culture and interpreting the system's output). The "human-in-the-loop" component primarily involves collecting and processing the specimen, loading it into the system, and then acting on the system's results.

    7. The Type of Ground Truth Used

    The ground truth used for these studies is based on:

    • Microbial Culture and Identification: The actual recovery and identification of mycobacteria from clinical specimens by established laboratory methods, including conventional culture and the predicate BACTEC 12B system. The "total pathogenic mycobacteria positive isolates" (38 cases) serves as the reference for recovery studies. The time until growth is detected by these established methods serves as the ground truth for time to detection.

    8. The Sample Size for the Training Set

    The document does not explicitly state a sample size for a "training set." This is because the BACTEC® MYCO/F-Sputa Culture Vials are a culture medium used with an instrument, not a machine learning or AI algorithm that requires a distinct training phase. The development of the medium and the BACTEC 9000MB system would have involved extensive R&D, but not a "training set" in the context of AI. The described studies are performance validation studies.

    9. How the Ground Truth for the Training Set Was Established

    As there is no distinct "training set" in the AI sense for this type of device, this question is not applicable. The development of the culture medium would have been guided by traditional microbiological principles and established methods for optimizing microbial growth and detection.

    Ask a Question

    Ask a specific question about this device

    K Number
    K972098

    Validate with FDA (Live)

    Date Cleared
    1997-07-28

    (54 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Antimicrobial Susceptibility Test Discs are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Fosfomycin Sensi-Discs® are intended for use in determining the susceptibility to Fosfomycin of a wide range of bacteria, including Enterococcus faecalis, Enterococcus faeclum, Escherichia coli, Citrobacter diversus, Citerobacter freundii, Entercbacter aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Proteus mirabilis, Proteus vulgaris, and Serratia marcesceus. Zone sizes used tor interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, Forest Pharmaceuticals, Inc., and received FDA approval under NDA No. 50-717.

    Use of BBL Fosfomycin Sensi-Discs®.for in .vitro .agar diffusion.susceptibility. testing is indicated when there is a need to determine the susceptibility of bacteria to Fosfomycin. Fosfomycin has been shown to be active against most strains of microorganisms listed below, as described in the Forest Pharmaceuticals, Inc., package insert for this antimicrobic.

    Active In Vitro and In Clinical Infections Against: Aerobic Gram-Positive Microorganisms Enterococcus faecalis Aerobic Gram-Negative Microorganisms Escherichia coli Active In Vitro Only Against: Aerobic Gram-Positive Microorganisms Enterococcus faeclum Aerobic Gram-Negative Microorganisms Citrobacter diversus Citerobacter freundii Enterobacter aerogenes Klebsiella oxytoca Klebsiella pneumoniae Proteus mirabilis Proteus vulgaris Serratia marcesceus

    Device Description

    Antimicrobial Susceptibility Test Discs

    AI/ML Overview

    The provided text describes a 510(k) submission for "Fosfomycin, 200 mcg, Sensi-Discs" and provides a "Summary of Safety and Effectiveness." However, it does not include detailed acceptance criteria or a study proving the device meets those criteria in the format requested. The document primarily focuses on the device's labeling, intended use, and substantial equivalence to a predicate device, rather than detailed performance study results with specific metrics.

    Therefore, most of the information requested in your prompt cannot be extracted directly from the provided text.

    Here's what can be gathered and what is missing:

    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: Not explicitly stated in terms of quantitative performance metrics for the device itself. The document mentions "Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, Forest Pharmaceuticals, Inc., and received FDA approval under NDA No. 50-717." This implies that the acceptance criteria for the interpretation of the device's results are based on established standards for Fosfomycin, but the performance of this specific Sensi-Disc against those criteria is not detailed.
    • Reported Device Performance: Not provided in a quantitative form (e.g., accuracy, sensitivity, specificity, reproducibility).

    2. Sample sized used for the test set and the data provenance

    • Sample Size for Test Set: Not specified.
    • Data Provenance (e.g., country of origin of the data, retrospective or prospective): Not specified.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • This information is not provided. The ground truth seems to be implicitly linked to the "Forest Pharmaceuticals, Inc., package insert for this antimicrobic" but how this was established in the context of the Sensi-Disc's performance is not detailed.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not specified.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • This device is an antimicrobial susceptibility test disc (a physical laboratory consumable), not an AI-assisted diagnostic tool. Therefore, an MRMC study comparing human readers with and without AI assistance is not applicable and not mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Again, this is not an algorithm or AI device. It's a laboratory consumable. Standalone performance as an algorithm is not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • The ground truth is implied to be based on the established clinical breakpoints and susceptibility interpretations for Fosfomycin, as determined by the antimicrobic manufacturer (Forest Pharmaceuticals, Inc.) and FDA-approved under NDA No. 50-717. This would typically involve correlation with minimum inhibitory concentration (MIC) testing (a gold standard for antibiotic susceptibility) and clinical outcomes data from the drug's initial approval. However, the specific method for establishing ground truth for this particular Sensi-Disc performance study is not detailed.

    8. The sample size for the training set

    • Not specified. This device is not an AI/machine learning model, so the concept of a "training set" in that context does not apply.

    9. How the ground truth for the training set was established

    • As above, not applicable in the context of AI/machine learning training.

    In summary, the provided document is a regulatory approval letter and a summary of the device's intended use and relationship to a predicate device. It lacks the detailed performance study data, acceptance criteria, and methodology that would typically be found in a clinical or validation study report.

    Ask a Question

    Ask a specific question about this device

    K Number
    K970385

    Validate with FDA (Live)

    Date Cleared
    1997-03-10

    (35 days)

    Product Code
    Regulation Number
    866.1620
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Antimicrobial Susceptibility Test Discs are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Sparfloxacin Sensi-Discs® are intended for use in determining the susceptibility to Sparfloxacin of a wide range of bacteria, including Staphylococcus aureus, Streptococcus pneumoniae (penicillin-susceptible strains), Enterobacter cloacae, Haemophilus influenzae, Haemophilus parainfluenzae, Klebsiella pneumoniae, Moraxella catarrhalis, Chlamydia pneumoniae, and Mycoplasma pneumoniae. Zone sizes used for interpretation of tests, including control organism limits, were determined by the antimicrobic manufacturer, Rhone Poulenc Rorer Pharmaceuticals, Inc., and received FDA approval under NDA No. 20-677.

    Use of BBL® Sparfloxacin Sensi-Discs® for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of bacteria to Sparfloxacin. Sparfloxacin has been shown to be active against most strains of microorganisms listed below, both in vitro and in clinical infections, as described in the Rhone Poulenc Rorer Pharmaceuticals, Inc., package insert for this antimicrobic.

    Device Description

    Sparfloxacin Susceptibility Test Discs are prepared by impregnating high quality paper with accurately determined amounts of Sparfloxacin supplied by the manufacturer, Rhone Poulenc Rorer Pharmaceuticals, Inc., Collegeville, Pennsylvania. Each Sparfloxacin disc is clearly marked on both sides with the agent and content. Sparfloxacin discs are furnished in cartridges of 50 discs each. Sparfloxacin cartridges are packed as either a single cartridge in a single box, or in a package containing ten cartridges.

    Agar diffusion methods employing dried filter paper discs impregnated with specific concentrations of antimicrobial agents were developed in the 1940's. In order to eliminate or minimize variability in the testing, Bauer et al. developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium.

    Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of these standardized procedures were those published by the U.S. Food and Drug Administration (FDA) and the World Health Organization (WHO). The procedure was adopted as a consensus standard by the National Committee for Clinical Laboratory Standards (NCCLS) and is periodically updated. The latest NCCLS documents are M2-A5 (12/93) and M100-S6 (12/95).

    Discs containing a wide variety of antimicrobial agents are applied to the surface of Mueller Hinton Agar plates [or Haemophilus Test Medium Agar for H. influenzae or Mueller Hinton Agar with 5% Sheep Blood for S. pneumoniae] inoculated with pure cultures of clinical isolates. Following incubation, the plates are examined and the zones of inhibition surrounding the discs are measured and compared with established zone size ranges for individual antimicrobial agents in order to determine the agent(s) most suitable for use in antimicrobial therapy. The determination as to whether the organism in question is susceptible (S), intermediate (I), or resistant (R) to an antimicrobial agent is made by comparing zone sizes to those found in the respective organism tables of National Committee for Clinical Laboratory Standards (NCCLS) Document M2-A5 ("Performance Standards for Antimicrobial Disk Susceptibility tests - Fifth Edition, Approved Standard", 12/93) and of NCCLS Document M100-S6 ("Performance Standards for Antimicrobial Susceptibility Testing", Sixth Informational Supplement, 12/95).

    AI/ML Overview

    This document describes the BBL® Sparfloxacin Sensi-Discs® for antimicrobial susceptibility testing. The data provided focuses on the clinical effectiveness of Sparfloxacin itself, rather than the performance of the Sensi-Discs® as a diagnostic device. The Sensi-Discs® are intended to determine the susceptibility of bacteria to Sparfloxacin using standardized agar diffusion tests.

    Here's an analysis of the provided information regarding acceptance criteria and supporting studies, contextualized for the device (Sparfloxacin Sensi-Discs®) where possible, and acknowledging that much of the performance data relates to the drug Sparfloxacin:

    1. Table of Acceptance Criteria and Reported Device Performance

    For the Sparfloxacin Sensi-Discs®, the acceptance criteria are not explicitly detailed in terms of a device-specific performance study with metrics like accuracy, sensitivity, or specificity against a reference method. Instead, the performance is tied to zone size interpretation and quality control ranges provided by the drug manufacturer (Rhone Poulenc Rorer Pharmaceuticals) and standardized by NCCLS.

    Acceptance Criteria (from NCCLS guidelines, applied to disc test)Reported Device Performance (Implicit via compliance with NCCLS)
    For aerobic microorganisms (other than Haemophilus influenzae):
    Zone Diameter ≥19 mm for Susceptible (S)Implied to meet these interpretive standards through product design and quality control, as per NCCLS M2-A5. The device's function is to produce these zones.
    Zone Diameter 16-18 mm for Intermediate (I)
    Zone Diameter ≤15 mm for Resistant (R)
    For Haemophilus influenzae and Haemophilus parainfluenzae:
    Zone Diameter ≥19 mm for Susceptible (S)Implied to meet these interpretive standards as above. "The current absence of data on resistant strains precludes defining any category other than 'Susceptible.'"
    Quality Control Ranges (Zone Diameter for Disc Diffusion):
    Escherichia coli ATCC 25922: 30-38 mmThe device is expected to produce zone diameters within this range for quality control organisms.
    Staphylococcus aureus ATCC 25923: 27-33 mmThe device is expected to produce zone diameters within this range for quality control organisms.
    MIC Interpretive Standards (Sparfloxacin drug performance, not disc diameter directly):
    ≤1 µg/mL for Susceptible (S) (for aerobic microorganisms other than Haemophilus influenzae)The drug (Sparfloxacin) exhibits these MIC values against various organisms. The discs are calibrated to reflect this.
    2 µg/mL for Intermediate (I)
    ≥4 µg/mL for Resistant (R)
    <0.25 µg/mL for Susceptible (S) (for Haemophilus influenzae and Haemophilus parainfluenzae)The drug (Sparfloxacin) exhibits these MIC values against various organisms. "The current absence of data on resistant strains precludes defining ones other than 'Susceptible.'"
    Quality Control Ranges (MIC values for Broth Microdilution):
    Enterococcus faecalis ATCC 29212: 0.12-0.5 µg/mLThe Sparfloxacin drug is expected to have MICs within this range for quality control organisms when tested by broth microdilution. The discs are calibrated to correlate.
    Escherichia coli ATCC 25922: 0.004-0.016 µg/mL
    Haemophilus influenzae ATCC 49247a: 0.004-0.016 µg/mL
    Staphylococcus aureus ATCC 29213: 0.03-0.12 µg/mL
    Streptococcus pneumoniae ATCC 49619b: 0.12-0.5 µg/mL

    The primary study mentioned directly concerning the device's acceptable performance is the adherence to the National Committee for Clinical Laboratory Standards (NCCLS) documents M2-A5 and M100-S6. These documents provide the standardized procedures for antimicrobial disk susceptibility tests, including zone size interpretation and quality control limits. The device, by its nature as an "Antimicrobial Susceptibility Test Disc," is designed to be used within these established guidelines.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not detail a specific "test set" for the Sparfloxacin Sensi-Discs® themselves, as the approval relies on adherence to established NCCLS standards and the clinical data for the drug Sparfloxacin.

    • For the drug Sparfloxacin clinical studies (Community-Acquired Pneumonia and Acute Bacterial Exacerbations of Chronic Bronchitis):
      • Community-Acquired Pneumonia:
        • Sparfloxacin: n=22 to 41 per organism (total = 199 unique pathogen-patient cases reported across listed organisms)
        • Erythromycin: n=4 to 15 per organism (total = 49)
        • Cefaclor: n=5 to 24 per organism (total = 124)
      • Acute Bacterial Exacerbations of Chronic Bronchitis:
        • Sparfloxacin: n=13 to 109 per organism (total = 269 unique pathogen-patient cases)
        • Ofloxacin: n=14 to 95 per organism (total = 277)
      • Data Provenance: The clinical studies were conducted "in the United States." The data is prospective, as these are clinical trials comparing drug efficacy.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided for the Sensi-Discs® themselves or for the clinical studies of the Sparfloxacin drug. For diagnostic device performance, establishing ground truth often involves reference methods performed by qualified laboratory personnel. For the Sensi-Discs®, the "ground truth" for interpretation is implicitly derived from the established NCCLS zone diameter breakpoints, which are scientifically determined standards rather than expert consensus on individual cases.

    4. Adjudication Method for the Test Set

    This information is not provided. For antimicrobial susceptibility testing, adjudication is typically not performed in the same way as in image-based diagnostic studies. The results are quantitative measurements (zone diameters) interpreted against predefined breakpoints. Clinical success in drug trials is usually determined by clinical outcomes and microbiological eradication, not an adjudication process by experts on individual treatment responses in the context of the device's performance.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    No MRMC study was done, as this document predates the widespread application of AI in diagnostics and the device (antimicrobial susceptibility disc) is not an AI-powered diagnostic tool. The "readers" in this context are laboratory technicians measuring zone diameters, and their performance is standardized and controlled by NCCLS guidelines and quality control measures, not by AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This is not applicable. The device is a physical disc used in a laboratory procedure requiring human measurement and interpretation. There is no "algorithm only" component.

    7. The Type of Ground Truth Used

    • For the Sparfloxacin Sensi-Discs® (as a diagnostic device): The ground truth is expert consensus-based standards and recognized reference methods. The interpretive zone sizes and quality control ranges are established by organizations like NCCLS (National Committee for Clinical Laboratory Standards) through a consensus process involving experts in microbiology and infectious diseases, validated against clinical outcomes and MIC data. The "gold standard" for determining MICs (Minimum Inhibitory Concentrations) is typically broth microdilution or agar dilution as per CLSI (formerly NCCLS) guidelines. The disc diffusion method is then correlated to these MIC values.
    • For the Sparfloxacin drug clinical trials: The ground truth for treatment effectiveness was clinical success (e.g., patient recovery, resolution of symptoms) and pathogen eradication (microbiological cure) demonstrated through follow-up cultures.

    8. The Sample Size for the Training Set

    The document does not describe a "training set" in the context of machine learning or AI. For the Sparfloxacin Sensi-Discs®, the "training data" for establishing breakpoints and QC ranges would implicitly be the extensive historical data and research collected by the NCCLS and drug manufacturers to correlate MICs with zone sizes and clinical outcomes. This would have involved numerous isolates and experiments over time, but is not quantified as a single "training set size" in this document.

    9. How the Ground Truth for the Training Set Was Established

    As discussed above, the concept of a "training set" with ground truth in the AI sense does not apply directly here. For antimicrobial susceptibility testing, the "ground truth" for establishing interpretive breakpoints and quality control ranges (which guide the use of the device) is established through:

    • Correlation studies: Comparing disc diffusion zone diameters with MIC values obtained from reference methods (e.g., broth microdilution) for a large number of bacterial isolates.
    • Clinical outcome data: Analyzing the clinical efficacy (patient response) and microbiological eradication rates of the drug in patients infected with organisms having specific MICs and corresponding disc diffusion zone diameters. This helps define the clinical relevance of "susceptible," "intermediate," and "resistant" categories.
    • Expert consensus: Committees like NCCLS (now CLSI) using all available scientific evidence, including in vitro data and clinical trial results, to determine and periodically update the breakpoints.

    In essence, the Sparfloxacin Sensi-Discs® rely on well-established and scientifically validated methodologies rather than new, device-specific performance studies against a novel ground truth. The "study that proves the device meets the acceptance criteria" is primarily the adherence to and validation against the NCCLS standards and the clinical data for the drug itself provided by Rhone Poulenc Rorer Pharmaceuticals.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 2