Found 3 results

510(k) Data Aggregation

    K Number
    K190192

    Validate with FDA (Live)

    Date Cleared
    2020-02-10

    (371 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The K3Pro® Konus New Abutments and Implants are designed to be compatible with the K3Pro® Konus Dental Implant system and are for use in edentulous sites in the maxilla for support of a complete denture prosthesis, a final or intermediate abutment for fixed bridgework or for partial dentures, or as a single tooth replacement. Delayed loading is recommended.

    The Ø7, 8, and 9mm implants are intended only for implantation in the maxillary or mandibular molar region where bone exists and the surgeon has determined that the placement of a narrower diameter implant would increase the probability of failure due to poor primary stability, or increased surgical procedures leading to complications.

    All digitally designed abutments for use with K3Pro® New Abutments and Implants are intended to be sent to an Argon validated milling center for manufacture.

    Device Description

    The K3Pro® Konus New Abutments and Implants are components of the K3Pro® Konus Dental Implant System. The submission includes new implant bodies (7.0mm and 8.0mm diameter, 3.0mm platform, 8.0 to 11.0mm length) made of Grade 4 titanium with Osteo-Active™ surface treatment, and additional Ti-Base abutments (KSA, CG.V, and CS) in 2.0mm and 3.0mm platform diameters made of Grade 5 Ti-6Al 4V-ELI. The abutments are designed to fit and function only on previously cleared K3Pro® Konus Dental Implants (K141159, K160581) and the implants submitted in this submission. They have the same Konus connection and are screw retained. Abutment screws are made of Grade 4 titanium. All devices are for single use only. Digitally designed abutments are intended for fabrication of patient-specific abutments using FDA cleared CAD/CAM technology and manufactured by an Argon Medical Productions validated milling center. Zirconium coping and/or crown for Ti-Base abutments are made of ZrO2 and luted with an FDA cleared cement.

    AI/ML Overview

    The provided text does not describe acceptance criteria for a device's performance, nor does it detail a study that proves the device meets such criteria.

    Instead, the document is a 510(k) premarket notification letter from the FDA regarding the K3Pro® Konus New Abutments and Implants. It focuses on demonstrating substantial equivalence to previously cleared predicate devices, rather than establishing new performance criteria or conducting studies to meet specific acceptance thresholds.

    The document discusses:

    • Indications for Use: What the device is intended for.
    • Technological Characteristics: How the device is similar to predicate devices in terms of materials, design, and manufacturing.
    • Non-Clinical Testing: A list of tests performed (e.g., sterilization validation, biocompatibility, fatigue testing) to show that the new device performs similarly and safely to the predicate devices. These are equivalence tests, not performance tests against specified acceptance criteria.

    Therefore, I cannot provide the requested information as it is not present in the given text. The document explicitly states: "No animal testing or human clinical trials have been conducted." and focuses on "similarities between the predicate and proposed devices" and "non-clinical performance to the predicates listed" to support substantial equivalence.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160581

    Validate with FDA (Live)

    Date Cleared
    2017-03-24

    (388 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    K3Pro Konus Additional Abutments and Implants are designed to be compatible with the K3Pro Konus Dental Implant system and are for use in edentulous sites in the mandible or maxilla for support of a complete denture prosthesis, a final or intermediate abutment for fixed bridgework or for partial dentures, or as a single tooth replacement. Delayed loading is recommended. The prosthesis may be secured to the abutment by the use of adhesives or mechanically by the use of a screw.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) Clearance letter from the FDA for a dental implant system. It does not contain any information about a study that proves a device meets acceptance criteria, an AI/ML powered device, or any performance metrics. Therefore, I cannot generate the requested information based on the input.

    The document states that the device is "substantially equivalent" to legally marketed predicate devices, which is the basis for 510(k) clearance, rather than requiring performance data against specific acceptance criteria as would be needed for a novel device or AI/ML product.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160574

    Validate with FDA (Live)

    Date Cleared
    2016-12-20

    (294 days)

    Product Code
    Regulation Number
    880.6850
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1