510(k) Data Aggregation

    K Number
    K220970

    Validate with FDA (Live)

    Date Cleared
    2022-07-15

    (102 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Renuvion® APR Handpiece is intended for the delivery of radiofrequency energy and/or helium plasma for cutting, coagulation and ablation of soft tissue during open surgical procedures.

    The Renuvion® APR Handpiece is indicated for use in subcutaneous dermatological and aesthetic procedures to improve the appearance of lax (loose) skin in the neck and submental region.

    The Renuvion® APR Handpiece is intended to be used with compatible electrosurgical generators owned by Apyx Medical (specifically BVX-200H, BVX-200P, APYX-200H, APYX-200P, APYX-RS3, and APYX-JS3).

    Device Description

    The Renuvion® APR Handpiece is a sterile, single-use electrosurgical (monopolar) device intended to be used in conjunction with compatible electrosurgical generators. The compatible generators operate at an adjustable power of up to 40W (expressed as 0-100% where 100% is 40W) and provide an adjustable helium gas flow of 1-5 LPM. Radiofrequency energy is delivered to the handpiece by the generator and used to energize the electrode. When helium gas passes over the energized electrode, a helium plasma is generated for soft tissue cutting, coaqulation or ablation.

    The Renuvion® APR Handpiece has a non-extendable electrode to generate helium plasma. The handpiece is available in two different lengths: 15cm and 27cm. The 15cm length is available in a single port (APYX-15-SP) as well as a twin port configuration (APYX-15-TP). The 27cm length is only available with a twin port configuration (APYX-27-TP).

    AI/ML Overview

    The provided document describes the K220970 Premarket Notification for the Renuvion APR Handpiece. The focus of this submission is not on a new device but on an expanded indication for use for an existing, previously cleared device (Renuvion APR Handpiece, cleared under K191542). Therefore, the "acceptance criteria" and "study that proves the device meets the acceptance criteria" are specifically related to proving the safety and effectiveness of the device for this new indication, rather than the core functionality of the electrosurgical device itself, as no modifications were made to the hardware.

    Here's a breakdown of the requested information based on the document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are effectively the primary and safety endpoints defined for the clinical study.

    Acceptance Criterion (Endpoint)Reported Device Performance
    Primary Effectiveness Endpoint: Improvement in the appearance of lax tissue in the neck and submental region at 180-days as determined by 2 out of 3 blinded Independent Photographic Reviewers.82.5% (52/63 subjects demonstrated improvement, with a 97.5% one-sided lower CL=70.9%, p<.0001)
    Primary Safety Endpoint: Proportion of subjects with none-to-moderate pain at 7 days, on a Numeric Rating Scale (NRS) through the 7-day follow-up visit. (Baseline NRS score was 0 in 100% of subjects).96.9% (62/64 subjects, with a 97.5% one-sided lower CL=89.2%, p<.0001)

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: 65 adults. The effectiveness endpoint was assessed on 63 subjects, and the safety endpoint on 64 subjects.
    • Data Provenance: The study was a "prospective, multi-center, evaluator-blinded study." The document does not explicitly state the country of origin, but given the FDA submission, it implicitly refers to data from a US-based or FDA-compliant clinical trial.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Number of Experts: 3 blinded Independent Photographic Reviewers.
    • Qualifications of Experts: The document does not explicitly state the qualifications of these reviewers (e.g., radiologist with X years of experience). They are referred to as "Independent Photographic Reviewers," implying expertise in assessing aesthetic outcomes from photographs.

    4. Adjudication Method for the Test Set

    • Adjudication Method: "Correct identification of the 'after' images by at least 2 of 3 blinded Independent Photographic Reviewers." This is a 2-out-of-3 majority consensus method.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • Was an MRMC study done? No, this was not an MRMC study comparing human readers with and without AI assistance. The study assessed the clinical effectiveness of the device itself by human evaluators of photographic outcomes. The device is not an AI algorithm.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • This is not applicable as the Renuvion APR Handpiece is a physical medical device that delivers energy and plasma for treatment, not an AI algorithm. Its performance is directly observed in patient outcomes or through human assessment of those outcomes. The "performance data" sections (Bench Testing, Electrical Safety, Biocompatibility, Pre-Clinical & Ex-Vivo) were all "N/A" for new testing because no modifications were made to the commercially available Handpiece cleared under K191542, indicating that these aspects were previously evaluated for the predicate device.

    7. The Type of Ground Truth Used

    • Type of Ground Truth: The ground truth for effectiveness was established by expert consensus based on the visual assessment of 2D photography images by 3 blinded Independent photographic reviewers. For safety, the ground truth was patient-reported outcomes (pain levels via Numeric Rating Scale).

    8. The Sample Size for the Training Set

    • Training Set Sample Size: This information is not applicable and not provided. The device isn't an AI model that requires a "training set" in the conventional sense. The entire clinical study (n=65) serves as the "test set" to prove the device's performance for its expanded indication.

    9. How the Ground Truth for the Training Set was Established

    • This is not applicable, as there is no "training set" for this device in the context of an algorithm or AI. The clinical trial data is the performance data used to support the claim.
    Ask a Question

    Ask a specific question about this device

    K Number
    K191484

    Validate with FDA (Live)

    Date Cleared
    2019-07-30

    (56 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Renuvion®/J-Plasma® Precise Handpiece is intended to be used with compatible electrosurgical generators for the delivery of helium plasma for cutting, coagulation and ablation of soft tissue during open and laparoscopic surgical procedures.

    The Renuvion®/J-Plasma® Precise Handpiece is compatible with the Electrosurgical Generators BVX-200H and BVX-200P manufactured by Apyx Medical.

    Device Description

    The Renuvion®/J-Plasma® Precise Handpiece is a sterile, single use electrosurgical accessory intended to be used in conjunction with compatible electrosurgical generators for the delivery of helium gas plasma for cutting, coagulating, and ablating soft tissue. The compatible Generators operate at an adjustable power of up to 40W (expressed as 0-100% where 100% is 40W) and provide an adjustable helium gas flow of 1-5 LPM. The Renuvion/J-Plasma Precise Handpiece is available with a retractable cutting tip blade for excising tissue. The blade tip serves as an electrode to generate helium plasma.

    The blade can be extended in 2mm increments from 0 to 10mm from the distal tip of the shaft via a ratcheted slider and retracted via a release latch. The device is activated via pressing the purple activation trigger. The handpiece is to be used with compatible electrosurgical generators, BVX-200H or BVX-200P, manufactured by Apyx Medical.

    The Renuvion®/J-Plasma® Precise Handpiece is available in a 33 cm length for use in laparoscopic or open surgical procedures. The 33 cm is a standard length for laparoscopic instruments and are compatible with standard 5 mm trocars.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification from Apyx Medical Corporation for their Renuvion®/J-Plasma® Precise Handpiece (Model # BVX-330 BPS). This submission describes a modification of an already cleared device and aims to demonstrate substantial equivalence to previously marketed predicate devices. Therefore, the "acceptance criteria" and "device performance" described are focused on proving this equivalence through various tests rather than establishing initial clinical efficacy with novel endpoints.

    Here's an analysis of the acceptance criteria and study that proves the device meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria / Test ObjectiveReported Device Performance (Result)
    Mechanical Performance & Functionality: Verify Mechanical functionality of the Renuvion®/J-Plasma® Precise Handpiece.Mechanical functionality requirements met.
    Tissue Effect (Plasma Activation): Verify that the tissue effects are similar between the subject device and the Primary Predicate device (K183610 & K151325).Tissue effects are equivalent between the subject device and Primary Predicate device.
    Tissue Effect (Monopolar Coagulation): Verify that the tissue effects are similar between the subject device and the Reference device (K183610 & K170188).Tissue effects are equivalent between the subject device and Reference device.
    Electrical Safety: Compliance with IEC 60601-1 and IEC 60601-2-2 standards.Determined to be in conformance with these standards.
    Electromagnetic Compatibility (EMC): Compliance with IEC 60601-1-2 standard.Determined to be in conformance with this standard.
    Biocompatibility: Evaluation in accordance with FDA guidance "Use of International Standard ISO 10993-1" for cytotoxicity, sensitization, irritation, systemic toxicity, hemolysis, and material mediated pyrogen/pyrogenicity.Biocompatibility has been established per ISO 10993 guidelines for the device's classification (external communicating device with indirect blood path contact < 24 hours). Biocompatibility verification testing was satisfactorily conducted.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the sample sizes (e.g., number of units tested) for the individual bench tests. The tests were performed as "bench testing," meaning they were conducted in a laboratory setting, not on human or animal subjects. The data provenance is internal to Apyx Medical Corporation and based on their design and development procedures and risk assessment in accordance with ISO 14971. No geographical provenance (country of origin for data) is specified beyond the company's location in Clearwater, Florida, USA. The tests are retrospective in the sense that they are comparing a modified device to previously cleared predicates, rather than a de novo clinical investigation.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This information is not provided in the document. For bench testing related to mechanical functionality, electrical safety, EMC, and biocompatibility, "experts" in the traditional sense of medical specialists establishing ground truth (like radiologists reading images) are not typically involved. Instead, the ground truth is defined by established engineering standards, material science principles, and biological safety guidelines. For tissue effect tests, conclusions are drawn from bench experiments and comparison to predicate devices, where the "ground truth" would be the observed tissue response under controlled conditions, compared to the known response of the predicate. The document doesn't detail the personnel or their qualifications who interpreted these tissue effects.

    4. Adjudication Method for the Test Set:

    An adjudication method (like 2+1 or 3+1 expert review) is not applicable here. These methods are common for clinical imaging studies where there's subjectivity in interpretation. For the bench tests described (mechanical, electrical, EMC, biocompatibility, and comparing tissue effects), the results are typically objectively measured and evaluated against predefined thresholds or comparative equivalence, not through expert consensus on subjective findings.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    An MRMC comparative effectiveness study was not performed, nor is it applicable to this submission. MRMC studies are used to evaluate the diagnostic performance of a device (often AI-based) in a clinical setting with multiple human readers and cases, typically to assess how the device aids human interpretation. This submission is for an electrosurgical handpiece, and the performance assessment is based on physical and biological characteristics, not diagnostic interpretation by human readers.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

    A standalone performance study is not applicable here. This device is a surgical instrument, not an algorithm or AI system. Its function is directly performed by the device itself, often with a human operator, but its primary performance endpoints are physical effects (cutting, coagulation) and safety, not an algorithmic output that could be independently evaluated.

    7. The Type of Ground Truth Used:

    The ground truth used for these tests is generally based on:

    • Engineering Specifications and Standards: For mechanical performance, electrical safety, and EMC, the ground truth is defined by established industry and international standards (e.g., IEC 60601 series) and the device's own design specifications.
    • Predicate Device Performance: For tissue effects, the ground truth for "equivalence" is the documented and cleared performance of the primary predicate device (for J-Plasma mode) and the reference device (for Monopolar Coagulation mode). The results of the subject device are compared to these established performances.
    • Biological Safety Guidelines: For biocompatibility, the ground truth is established by international standards like ISO 10993 guidelines, which define acceptable biological responses for device materials.

    8. The Sample Size for the Training Set:

    This information is not applicable because this is a medical device, not an AI/ML product that requires a training set for algorithm development. The "design controls process" and "verification and validation" mentioned refer to engineering and quality assurance processes for medical devices, not to machine learning training.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable as there is no training set for an AI/ML algorithm involved in this device submission.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1