510(k) Data Aggregation

    K Number
    K252412

    Validate with FDA (Live)

    Date Cleared
    2025-10-31

    (91 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Advanced Bipolar: The Voyant electrosurgical generator is indicated for use with advanced bipolar Voyant devices in open and minimally invasive procedures where the ligation of vessels up to and including 7mm in diameter and tissue bundles is desired.

    NOTE: For indications specific to each Voyant device used with the Voyant generator, refer to each device's Instructions for Use (IFU).

    Monopolar/Bipolar: Intended to provide energy to standard monopolar and bipolar surgical accessories.

    Device Description

    The Applied Medical Voyant Electrosurgical Generator (EA030) is a reusable, electrically isolated, microprocessor-controlled power supply intended to deliver radiofrequency (RF) energy for electrosurgical applications. The system provides energy output to compatible monopolar, bipolar, and Voyant advanced bipolar instruments for the cutting, coagulation, and sealing of vessels and tissue bundles. The Voyant EA030 operates outside the sterile field and interfaces with active surgical instruments that operate within the sterile field. The system comprises integrated mechanical, electrical, and software components, constructed from various metals and polymers. It features a front-panel LCD touchscreen that enables users to view, navigate and adjust operating modes and system settings.

    Voyant EA030 is designed to function as part of a system that includes optional accessories such as active devices, footswitches, and patient return electrodes. These components work together to ensure safe and effective energy delivery during surgical procedures.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K232880

    Validate with FDA (Live)

    Date Cleared
    2023-11-01

    (44 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Applied Medical's Inzii Ripstop Redeployable Retrieval System is indicated for use as a receptacle for the collection and extraction of tissue, organs, and calculi during general and laparoscopic surgical procedures.

    Device Description

    The Inzii Ripstop Redeployable Retrieval System is a single-use device designed for the containment and extraction of multiple tissue specimens. The device consists of a flexible specimen bag and an introducer tube which can be redeployed for multiple uses within a single procedure. The product will be available in two models, a 10 mm model with a 265 ml specimen bag and a 15 mm model with a 1600 ml specimen bag size. The device is provided sterile and is constructed of a Ripstop nylon specimen bag, various polymers and stainless steel. The major differences between the predicate and the subject device include the subject device featuring a stronger Ripstop nylon specimen bag and the ability to be redeployed multiple times within a single surgical procedure.

    AI/ML Overview

    The Inzii Ripstop Redeployable Retrieval System is a single-use device designed for the containment and extraction of multiple tissue specimens. The study aims to demonstrate substantial equivalence to its predicate device, the Inzii Tissue Retrieval System (K060051), by performing non-clinical bench tests and simulated use tests.

    Acceptance Criteria and Reported Device Performance:

    Performance TestAcceptance CriteriaReported Device Performance
    Specimen Retrieval System Functionality testingThe device must demonstrate proper deployment, retraction (for redeployment), and cinching mechanisms. It must effectively contain and allow for the extraction of specimens.The subject device demonstrated proper deployment, the ability to be retracted for redeployment multiple times within a single surgical procedure, and effective cinching for final retrieval. It successfully contained and allowed for extraction of specimens, meeting the functional requirements.
    Specimen Retrieval System Leak testingThe specimen bag must be liquid-tight and prevent leakage of contents during simulated use and retrieval, ensuring no spillage of bodily fluids or extracted materials.The specimen bags of the Inzii Ripstop Redeployable Retrieval System demonstrated liquid-tight integrity. No leakage was observed during simulated use or retrieval, confirming its ability to prevent spillage as required.
    Specimen Bag Closure testingThe bag closure mechanism (cord loop) must reliably and securely close the bag, preventing accidental opening or spillage of contents during retrieval.The cord loop closure mechanism was found to be reliable and secure, effectively closing the bag and preventing accidental opening or spillage of contents during simulated retrieval procedures.
    Specimen Bag Tear Resistance TestThe Ripstop nylon specimen bag must exhibit superior tear resistance compared to the predicate device's polyurethane bag, ensuring the integrity of the bag during specimen collection and retrieval.The Ripstop nylon specimen bag of the subject device demonstrated significantly higher tear resistance compared to the predicate device, as confirmed by additional testing referenced from K100959. This ensures enhanced integrity and durability during use.
    Specimen Bag Strength testingThe bag must withstand forces encountered during specimen retrieval, ensuring it does not rupture under typical surgical loads.The specimen bag demonstrated adequate strength, withstanding the forces typically encountered during specimen retrieval without any rupture or compromise to its integrity.
    Specimen Bag Pressure testingThe specimen bag must endure internal pressure from contained specimens without bursting or leaking.The specimen bag successfully endured internal pressure from contained specimens without bursting, leaking, or showing signs of structural failure.
    Specimen Bag Puncture testingThe specimen bag must resist accidental punctures from instruments or sharp edges of extracted specimens, maintaining its barrier function.The specimen bag exhibited resistance to accidental punctures from surgical instruments and sharp edges of extracted specimens, effectively maintaining its barrier function and preventing compromise of the contained material.
    Biocompatibility (Cytotoxicity, Sensitization, Intracutaneous Irritation, Acute Systemic Toxicity, Material Mediated Pyrogenicity)The device must pass all biological endpoints as per EN ISO 10993-1; 2020 for an externally communicating device with limited contact duration (up to 24 hours), contacting tissue/bone/dentin.The device successfully passed all required biological endpoints: Cytotoxicity, Sensitization, Intracutaneous Irritation, Acute Systemic Toxicity (AST), and Material Mediated Pyrogenicity (MMP), confirming its biocompatibility for the intended use and contact duration.

    Study Information:

    1. Sample sizes used for the test set and data provenance:

      • The document does not explicitly state the exact sample sizes for each specific performance test (e.g., number of devices tested for leak, strength, etc.). It refers to "sample size" generally in the context of the performance data summary.
      • The data provenance is from non-clinical bench tests and simulated use tests conducted by Applied Medical Resources Corporation. There is no indication of country of origin for data or whether it's retrospective or prospective, as these are bench tests.
    2. Number of experts used to establish the ground truth for the test set and qualifications:

      • This information is not applicable as the document describes performance testing of a physical medical device (specimen retrieval system), not an AI/software device that requires expert-established ground truth. The 'ground truth' here is the objective outcome of the physical/mechanical and biological tests.
    3. Adjudication method for the test set:

      • This is not applicable for the type of device and testing described. Adjudication methods like 2+1 or 3+1 are typically used for clinical studies involving reader interpretations, not for bench testing of physical device performance.
    4. Multi-Reader Multi-Case (MRMC) comparative effectiveness study:

      • No, an MRMC comparative effectiveness study was not done. This type of study is relevant for AI-powered diagnostic/interpretive devices where human readers' performance is augmented by AI. The Inzii Ripstop Redeployable Retrieval System is a physical surgical tool.
    5. Standalone (algorithm only without human-in-the-loop performance) study:

      • No, a standalone study was not done. This concept is specific to AI algorithms. The device described functions with human interaction during surgery.
    6. Type of ground truth used:

      • For the performance testing, the "ground truth" used was based on objective measurements and observations from the non-clinical bench tests and simulated use tests. This includes parameters like liquid tightness, resistance to tearing/puncture, and mechanical functionality, as well as established ISO standards for biocompatibility.
    7. Sample size for the training set:

      • This information is not applicable as the document describes performance testing of a physical medical device, not an AI/machine learning model that requires a training set.
    8. How the ground truth for the training set was established:

      • This information is not applicable as there is no training set for a physical medical device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K222284

    Validate with FDA (Live)

    Date Cleared
    2022-10-14

    (74 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Voyant Maryland Fusion Device with Single-Step Activation is a bipolar, electrosurgical device indicated for use with the Voyant electrosurgical generator in open and laparoscopic procedures where the ligation of vessels and tissue bundles is desired. The device can seal and divide vessels up to and including 7mm in diameter and tissue bundles that can be captured in the jaws of the device.

    The device has not been shown to be effective for tubal coagulation for sterilization procedures, and should not be used for these procedures.

    Device Description

    The Voyant Maryland Fusion device with Single Step is an advanced bipolar instrument that uses RF energy, provided by the Voyant Electrosurgical Generator (K182244), to seal vessels up to and including 7mm in diameter. The device may also be used to seal tissue bundles that can be captured in the device jaws. The device features a mechanical, user-actuated blade for the division of sealed tissue.

    AI/ML Overview

    The medical device in question is the Voyant® Maryland Fusion Device with Single-Step Activation. It is an electrosurgical device intended for use with the Voyant Electrosurgical Generator to seal and divide vessels and tissue bundles up to 7mm in diameter.

    Based on the provided text, here's an analysis of the acceptance criteria and supporting studies:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not provide a direct table with specific numerical acceptance criteria and corresponding reported device performance values. Instead, it states that the devices "met all acceptance criteria" or that results were "sufficient to represent the subject device is safe and effective."

    Acceptance Criteria CategoryReported Device Performance
    EMC, Electrical Safety, and Mechanical TestingThe predicate device met all acceptance criteria in accordance with relevant standards of the IEC 60601 series. Additional electrical safety testing on the subject device also met all acceptance criteria.
    Simulated Repeated-Use TestingThe subject device met the predetermined acceptance criteria for continued performance over multiple device activations.
    System Testing (Burst Pressure)(Performed on predicate device) Representative vessels were sealed, and burst pressure was recorded. The results are considered representative of system performance for the subject device. (No specific threshold or value is provided, but implies satisfactory burst pressure).
    System Testing (Thermal Spread)(Performed on predicate device) Thermal spread damage was evaluated. The results are considered representative of system performance for the subject device. (No specific thermal spread limit is provided, but implies acceptable thermal effects).
    Animal Testing (Long-term Seal Quality, Adverse Effects)(Performed on predicate device) Evaluated long-term seal quality, device performance, and potential for adverse effects on adjacent structures in large porcine animal models. Vessels were sealed and evaluated for hemostasis and signs of hematoma. The results are sufficient to represent the subject device is safe and effective.
    Software VerificationUnit, integration, and system level software testing were conducted to evaluate design, implementation, and performance. (Implies all tests passed the defined acceptance criteria for software).

    Note: The document generally indicates that the device "met all acceptance criteria" without specifying the exact numerical thresholds for many of these criteria. This type of summary is common in 510(k) submissions where the focus is on demonstrating substantial equivalence rather than presenting a detailed performance report.


    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the exact sample sizes for all test sets. However, it provides some information:

    • Burst pressure testing: "vessels representative of the devices' indications" were used. (No specific number mentioned).
    • Thermal spread testing: (No specific number mentioned).
    • Simulated repeated-use testing: (No specific number mentioned for activations or devices).
    • Animal testing: "large porcine animal models" were used. The number of animals or vessels tested is not specified.

    Data Provenance:

    • Country of Origin: Not explicitly stated, but typically these studies are conducted by the manufacturer or contract research organizations, often in the country where the manufacturer is based (USA, in this case).
    • Retrospective or Prospective: The testing described (simulated repeated-use, system testing, animal testing, software verification) are all prospective studies, designed and executed to evaluate the new or modified device. The reference to the predicate device's data suggests that previously collected prospective data from the predicate was leveraged.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not provide any information about the number or qualifications of experts used to establish ground truth for any of the described performance tests. For electrosurgical devices, "ground truth" often refers to objective measurements (e.g., burst pressure, thermal spread measurements, histopathological analysis in animal studies) rather than subjective expert interpretations like in imaging studies.


    4. Adjudication Method for the Test Set

    The document does not specify any adjudication method. Given that most of the described tests are objective measurements (e.g., electrical parameters, burst pressure, thermal spread, software testing), an adjudication method as typically understood in studies involving human interpretation (like imaging reads) would not be applicable. For animal studies, evaluation of hemostasis and hematoma would typically follow pre-defined histological or gross pathology criteria.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. The device is a direct-use surgical instrument, not an AI-based diagnostic tool requiring human interpretation/reading. Therefore, the concept of human readers improving with AI assistance is not applicable here.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    While the term "standalone" typically refers to AI algorithms, in the context of this electrosurgical device, the device itself is a "standalone" instrument. The performance tests (electrical, mechanical, system, animal) described are evaluating the performance of the device only (or the device in combination with its specified generator), without a human-in-the-loop actively assisting in output. The software verification tests are also standalone evaluations of the algorithm's performance within the device's control systems.


    7. The Type of Ground Truth Used

    The ground truth used for various tests includes:

    • Objective Measurements: For burst pressure (quantifiable pressure values), thermal spread (measurable tissue damage), and electrical safety/EMC (compliance with quantifiable standards).
    • Biological/Pathological Outcomes: For animal studies, this would involve macroscopic and potentially microscopic examination of sealed vessels and surrounding tissues to assess hemostasis, presence of hematoma, and tissue damage, serving as the "ground truth" for seal quality and safety.
    • Software Design Specifications: For software verification, the "ground truth" is adherence to predefined design requirements and functional specifications.

    8. The Sample Size for the Training Set

    The document describes performance testing for an electrosurgical device, not an AI/ML product. Therefore, the concept of a "training set" (used for training machine learning models) is not applicable to this submission.


    9. How the Ground Truth for the Training Set Was Established

    As the concept of a "training set" is not applicable, the question of how its ground truth was established is also not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K220969

    Validate with FDA (Live)

    Date Cleared
    2022-09-16

    (165 days)

    Product Code
    Regulation Number
    884.1630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GelPOINT V-Path Vaginal Access System (VAS) is intended to be inserted in the vagina to allow for entry of minimally invasive instruments while maintaining insufflation for vaginal gynecological procedures.

    Device Description

    The GelPOINT V-Path Vaginal Access System consists of an Intravaginal Alexis retractor and two access channels that are placed vaginally to create a pathway to gynecological organs. A GelSeal cap attaches to the retractor at the opening of the vagina. The cap allows for insufflation and smoke evacuation. Sleeves inserted through the cap allow for passage of 5mm to 12mm instrumentation. Visualization is achieved via introduction of an endoscope through a sleeve. The device is provided sterile.

    AI/ML Overview

    This document is a 510(k) summary for the GelPOINT® V-Path Vaginal Access System. It describes the device, its intended use, and the studies conducted to demonstrate its substantial equivalence to a predicate device.

    Here's an analysis of the provided text in relation to your request:

    1. Table of acceptance criteria and the reported device performance:

    The document describes functional testing but doesn't explicitly state quantitative acceptance criteria or provide specific numerical device performance metrics in a table format. Instead, it describes general successful outcomes.

    Acceptance Criteria (Inferred from study goals)Reported Device Performance (Summary of results)
    Ability to maintain transvaginal access.The studies confirm that the GelPOINT V-Path Vaginal Access System has the ability to establish and maintain a path of entry for minimally invasive instruments.
    Ability to facilitate instrument access to the surgical site.The studies confirm that the GelPOINT V-Path Vaginal Access System has the ability to establish and maintain a path of entry for minimally invasive instruments.
    Ability to allow for device removal.The studies confirm that the GelPOINT V-Path Vaginal Access System has the ability to allow for device removal. (Inferred from "Device removal" being an assessed function).
    Ability to maintain device retention/anchoring.The studies confirm that the GelPOINT V-Path Vaginal Access System can remain anchored in the patient while withstanding conditions under normal clinical use.
    Ability to maintain insufflation.The studies confirm that the integrity and sealing capability of the device system are adequate to maintain insufflation as a means to provide visualization of the surgical space.
    Biocompatibility (non-cytotoxic, non-sensitizer, non-irritant, non-systemically toxic, non-pyrogenic).The biocompatibility test results demonstrate the GelPOINT V-Path Vaginal Access System is biocompatible and has met the criteria to be classified as non-cytotoxic, non-sensitizer, non-irritant, non-systemically toxic, and non-pyrogenic.
    Shelf-life of 3 years.Results from testing demonstrated that the devices could maintain their specifications over the stated shelf-life duration of 3 years.

    2. Sample size used for the test set and the data provenance:

    • Sample Size for Test Set: The document mentions "bench testing" and "Functional bench testing" but does not provide specific sample sizes (e.g., number of devices tested, number of trials).
    • Data Provenance: The studies were internal company studies ("A protocol was developed by Applied Medical"). There is no mention of country of origin of data, and these are laboratory bench tests, not patient data, so the retrospective/prospective distinction is not applicable in the usual sense for clinical data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not provided in the document. The studies are described as functional bench tests, suggesting engineering or quality assurance personnel would evaluate the performance rather than clinical experts establishing a ground truth in the context of diagnostic accuracy.

    4. Adjudication method for the test set:

    This information is not provided. Given the nature of bench testing, it's unlikely an adjudication method like 2+1 or 3+1 (typically used for clinical imaging assessments) would be applied.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • MRMC Study: No.
    • AI Assistance: The document describes a medical device for surgical access, not an AI-powered diagnostic or assistive tool. Therefore, a study on human readers improving with AI assistance is not applicable and was not conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    No. This is a physical medical device, not an algorithm, so "standalone algorithm performance" is not applicable.

    7. The type of ground truth used:

    For the functional tests, the "ground truth" would be the successful demonstration of the device's intended functions (e.g., maintaining an open pathway, retaining its position, maintaining insufflation). For biocompatibility, the ground truth is established by meeting the pass/fail criteria outlined in the referenced ISO standards and USP <151>. For shelf-life, the ground truth is the device maintaining specifications after accelerated aging.

    8. The sample size for the training set:

    Not applicable. This is not an AI/machine learning device that requires a training set.

    9. How the ground truth for the training set was established:

    Not applicable. As above, this is not an AI/machine learning device.

    In summary:

    This 510(k) summary focuses on demonstrating the substantial equivalence of a physical surgical access device through functional bench testing, biocompatibility testing, and shelf-life studies. It does not involve clinical studies with patient data, expert review of images, or artificial intelligence algorithms. Therefore, many of your requested points related to AI performance, reader studies, and large-scale data sets are not relevant to this type of device submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K211043

    Validate with FDA (Live)

    Date Cleared
    2022-03-31

    (357 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Alexis® Contained Extraction System is indicated to contain and isolate tissue during, or prior to, surgical removal and/or extracorporeal manual morcellation via an abdominal or vaginal approach.

    Device Description

    The Alexis® Contained Extraction System is a sterile, single use tissue bag with a guard system component. The polyurethane tissue bag consists of a flexible ring, tabs, strap with a snap fastener, and an attached tether It is available in two models GTB14 and GTB17 with the following dimensions and volumes:

    ModelRing DiameterVolume
    GTB1414 cm3,400 mL
    GTB1717 cm6,500 mL

    The tissue bag is used to contain and isolate specimens for surgical removal and/or manual morcellation. The strap with snap fastener maintains the folded bag and flexible ring in a collapsed state during insertion. After the device is fully inserted and deployed into the abdominal or pelvic cavity, the opening of the bag returns to its original, circular shape, facilitating placement of the specimen in the bag. When the specimen is ready for removal and/or manual morcellation, the tether, tabs, and strap are used to maneuver the ring to the surface of the extraction site.

    If the specimen requires manual morcellation. the ring may be repeatedly flipped to shorten the bag and consequently bring the specimen closer to the extraction site.

    The guard system consists of a guard and a self-retaining retractor. The guard is composed of a coiled polyethylene material that conforms to the extraction site. The self-retaining retractor consists of two polyurethane rings connected by a polyurethane sheath and a tether attached to the inner ring. It helps anchor the guard at the extraction site. The guard system provides a robust barrier between the bag and sharp instruments.

    The Alexis® Contained Extraction System can be inserted and retrieved either through an abdominal incision or through the vaginal canal and colpotomy. In both cases, manual morcellation is performed extracorporeally at the extraction site.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Alexis® Contained Extraction System. This notification focuses on demonstrating substantial equivalence to a predicate device rather than providing a detailed study report with specific performance metrics and acceptance criteria for a new AI/software device.

    Therefore, the requested information regarding acceptance criteria, reported device performance, sample size for test sets (including provenance, expert qualifications, and adjudication methods), MRMC studies, standalone performance, ground truth establishment, and training set details cannot be extracted from the provided text.

    The document details engineering tests related to the physical device's characteristics (biocompatibility, sterilization, shelf life, and functional performance) to support its substantial equivalence to an existing device, as opposed to clinical performance data against defined metrics for a diagnostic or AI-driven system.

    The "Discussion of Performance Data" section refers to:

    • Biocompatibility: Evaluation in accordance with ISO 10993-1 and FDA guidance.
    • Sterilization/Shelf Life: Validation performed in accordance with ISO 11135-2.
    • Functional Performance: Design Verification testing for various physical attributes (e.g., integrity of tissue bag, tether, guard system, resistance to penetration, ability to maintain a closed system, specimen capture). This also included "simulated use testing with the subject device in both an abdominal bench model and a vaginal bench model."

    However, these are engineering and safety tests typical for a physical medical device, not performance studies as would be conducted for a diagnostic algorithm or AI system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K202049

    Validate with FDA (Live)

    Date Cleared
    2021-09-07

    (410 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Python catheters are indicated for removal of thromboemboli from the peripheral arterial system, and for occlusion and infusion of fluids into a vessel.
    The Over-the-Wire Latis Graft Cleaning Catheter is indicated for the removal of thromboemboli from vascular grafts, and for occlusion and infusion of fluids into a graft.

    Device Description

    The Python Embolectomy Catheter & Over-the-Wire Latis Graft Cleaning Catheters are sterile, single use vascular balloon catheters intended for use in the removal of thromboemboli, occlusion of vessels, and the infusion of fluids. The devices are intended for use in arterial vessels and artificial vascular grafts respectively. The body of the catheters utilize a dual lumen design with one inflation lumen used to inflate the balloon, and one through lumen allowing for insertion over a guide wire or infusion of fluids. The outer diameter of the body is designed to accommodate use with a standard percutaneous access sheath. The Over-the-wire Latis Graft Cleaning Catheter includes a braided mesh which surrounds the balloon and is designed to increase engagement with wall of artificial vascular graft.

    AI/ML Overview

    The provided text describes a medical device's 510(k) submission to the FDA, demonstrating substantial equivalence to predicate devices. It focuses on the physical and material characteristics of the catheters and the bench testing performed. However, it does not contain information pertinent to the typical acceptance criteria or study design for AI/ML-based medical devices, such as a test set size, data provenance, expert qualifications, adjudication methods, MRMC studies, standalone performance, or training set details.

    Therefore, I am unable to provide the requested information based on the input text.

    The document discusses the following:

    • Device Name: Python Catheter and Over-the-Wire Latis Graft Cleaning Catheter
    • Intended Use: Removal of thromboemboli from the peripheral arterial system/vascular grafts, and for occlusion and infusion of fluids into a vessel/graft.
    • Testing Performed:
      • Engineering/Bench Testing: Balloon Pull Force, Inflation & Guidewire Hub Pull Force, Catheter Body Tensile Strength, Catheter Balloon Cycling Test, Balloon Burst Pressure Test, Inflated Balloon Diameter Inspection, Guidewire & Inflation Hub Leak Test, Simulated Use Bend Test, Torsion Test, Kink Test.
      • Biocompatibility Testing: Cytotoxicity, Intracutaneous Irritation, Sensitization, Acute Systemic Toxicity, Hemolysis, Materials Mediated Pyrogenicity, Platelet and Leukocyte Counts, Partial Thromboplastin Time, Complement Activation, Thrombogenicity.
    • Standards Referenced: ISO 10555-1:ed2:2017 and EN 13868.

    This information relates to the physical and biological safety and performance of the catheter itself, not to the performance of an AI/ML component.

    Ask a Question

    Ask a specific question about this device

    K Number
    K190331

    Validate with FDA (Live)

    Date Cleared
    2019-11-22

    (281 days)

    Product Code
    Regulation Number
    878.4750
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Applied Medical Laparoscopic Linear Cutter has applications in open and/or minimally invasive general, urologic, gynecologic, pediatic and thoracic surgery for resection and or creation of anastomosis. The instruments may also be used for transection of liver parenchyma (hepatic vasculature and biliary structures), pancreas, kidney and spleen. It can be used with staple line or tissue buttressing materials.

    Device Description

    The Applied Medical Laparoscopic Linear Cutter (LLC) is a sterile, single-use stapling system that is intended to be used for mechanically transecting, resecting, and sealing tissue during laparoscopic and open surgical procedures. The stapler places six staggered rows of titanium staples, three on either side of the transection line. The shaft can rotate freely in both directions and the jaws articulate to facilitate access to the operative site. The Applied LLC is available in 3 different shaft lengths (20cm, 37cm, 50cm) that can each accommodate 3 different industrystandard reload lengths (60mm, 45mm, 30mm). Each of the reload lengths is available in three industry-standard reload colors and formed staple heights to accommodate various tissue thicknesses: 1.0mm (white reload), 1.5mm (blue reload), and 2.0mm (green reload).

    AI/ML Overview

    This document describes the FDA's 510(k) clearance for the Applied Medical Laparoscopic Linear Cutter (LLC), asserting its substantial equivalence to a predicate device. As such, the information provided focuses on the performance testing conducted to demonstrate this equivalence rather than a study proving a device meets specific clinical acceptance criteria for an AI/CADe device.

    Therefore, many of the requested categories for AI/CADe systems (e.g., number of experts, adjudication methods, MRMC studies, training set details) are not applicable to this type of medical device submission. The device in question is a surgical stapler, not an AI or imaging diagnostic tool.

    However, I can extract the information relevant to establishing the substantial equivalence of this device based on the provided text.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document states that "All performance testing acceptance criteria were met." It does not provide the specific numerical acceptance criteria for each test or detailed quantitative results, but rather lists the tests performed and their objectives.

    Test CategoryTest NameTest ObjectiveReported Performance (Qualitative)
    Bench TestsFiring ForceTo evaluate the input force required to actuate the triggerAcceptance criteria met
    Leak TestTo evaluate staple line leak pressuresAcceptance criteria met
    Articulation TestingTo evaluate device performance when fully articulatedAcceptance criteria met
    Reinforcement Material CompatibilityTo evaluate device performance with reinforcement materialAcceptance criteria met
    Shelf Life TestingTo evaluate device performance after simulated transit and storage conditionsAcceptance criteria met
    Staple FormationTo evaluate staple formation in media and out of mediaAcceptance criteria met
    Formed Staple HeightTo measure the formed staple heightAcceptance criteria met
    Radiograph ImagingTo evaluate location and quality of staple formation in mediaAcceptance criteria met
    Tissue Compression EvaluationTo evaluate tissue effects associated with application of the deviceAcceptance criteria met
    Crossed Staple LineTo evaluate device performance when fired across existing staple lineAcceptance criteria met
    Preclinical Tests21-Day Porcine Chronic Survival StudyTo evaluate in vivo device performance including in vivo hemostasis and histopathological evaluationsAcceptance criteria met
    Acute Porcine In-Vivo StudyTo evaluate device performance on high pressure arteries and thin-walled veinsAcceptance criteria met
    Biocompatibility TestsEthylene Oxide ResidualPer ISO 10993-7Acceptance criteria met
    Material Mediated PyrogenicityPer USP 40-NF 35:<151>Acceptance criteria met
    CytotoxicityPer ISO 10993-5Acceptance criteria met
    SensitizationPer ISO 10993-10Acceptance criteria met
    Acute Systemic ToxicityPer ISO 10993-11Acceptance criteria met
    Intracutaneous ReactivityPer ISO 10993-10Acceptance criteria met
    Intramuscular Implant Testing (2 & 13 week)Per ISO 10993-6Acceptance criteria met
    Toxicological Risk AssessmentReproductive and Developmental ToxicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met
    Subacute ToxicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met
    Subchronic ToxicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met
    Chronic ToxicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met
    GenotoxicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met
    CarcinogenicityBased on chemical characterization (per ISO 10993-18)Acceptance criteria met

    2. Sample size used for the test set and the data provenance

    • Test Set (Preclinical Studies): Two porcine studies were conducted. The specific number of animals or cases in these studies is not detailed in the provided text.
    • Data Provenance: The studies are described as "preclinical testing" which typically implies laboratory animal studies. The country of origin is not specified but implicitly within the context of an FDA submission, the testing would be expected to meet U.S. regulatory standards. These are prospective studies given they are conducted specifically for the regulatory submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not applicable / Not specified. This device is a surgical instrument, and its performance evaluation involves physical and biological testing, not expert interpretation of diagnostic images.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. This concept pertains to establishing ground truth for diagnostic image interpretation, which is not relevant to the testing of a surgical stapler.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This study design is for evaluating AI/CADe systems in diagnostic imaging. The Applied Medical Laparoscopic Linear Cutter is a surgical device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This device is a manual surgical instrument. No algorithm is involved.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • For Bench Tests: Ground truth is established through physical measurements, engineering standards, and biological models (e.g., media, tissue analogues).
    • For Preclinical Tests: Ground truth is established through direct observation of in-vivo performance (e.g., hemostasis) and histopathological evaluations of animal tissues post-procedure.
    • For Biocompatibility Tests: Ground truth is established by standardized biological assays (e.g., cytotoxicity, sensitization, systemic toxicity) and chemical characterization following specific ISO standards.

    8. The sample size for the training set

    • Not applicable. This device is not an AI/machine learning system. There is no concept of a "training set."

    9. How the ground truth for the training set was established

    • Not applicable. As above, no training set for an AI/ML model exists for this device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K180699

    Validate with FDA (Live)

    Date Cleared
    2018-04-13

    (28 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Voyant Open Fusion Device is a bipolar, electrosurgical device indicated for use with the Voyant electrosurgical generator in open procedures where the ligation and division of vessels and tissue bundles is desired.

    The device can seal and divide vessels up to and including 7mm in diameter and tissue bundles that can be captured in the jaws of the device.

    The device has not been shown to be effective for tubal coagulation for sterilization procedures, and should not be used for these procedures.

    Device Description

    The Voyant® Open Fusion device is a bipolar electrosurgical instrument that uses RF energy, provided by the Voyant Electrosurgical Generator (K141288), in open procedures where the ligation and division of vessels up to and including 7 mm in diameter and tissue bundles are desired.

    AI/ML Overview

    Based on the provided text, the device in question is the Voyant Open Fusion Device, an Bipolar Electrosurgical Sealer-Divider. The document describes its premarket notification (510(k)) to the FDA, asserting its substantial equivalence to a predicate device (Voyant® Open Fusion Device, K162676).

    It's important to note that this document pertains to an electrosurgical device used for sealing and dividing vessels and tissue bundles, not an AI/algorithm-based diagnostic or prognostic device. Therefore, many of the typical acceptance criteria and study aspects listed in the prompt (e.g., sample size for AI test sets, number of experts for ground truth, MRMC studies, standalone algorithm performance, training set details) are not applicable to this type of medical device submission.

    The "study" described focuses on the device's physical and functional performance, rather than the performance of an AI algorithm.

    Here's a breakdown of the requested information based on the provided text, highlighting what is applicable and what is not:


    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    Electrical SafetyThe Voyant Open Fusion Device complies with IEC 60601-1;ed.3.1;2012 and IEC 60601-2-2;ed.6;2017.
    Electromagnetic Compatibility (EMC)The Voyant Open Fusion Device complies with IEC 60601-1-2;ed.3;2007.
    Mechanical Performance (Durability)Durability testing was performed to verify the continued performance of the subject device over multiple device activations. The result of the study demonstrated that the subject device met the predetermined acceptance criteria.
    Burst Pressure (Vessel Sealing Strength)Burst pressure testing was conducted on the subject and predicate Voyant Open Fusion Devices. Vessels representative of the devices' indications were sealed and the burst pressure for each vessel was recorded. The results of the study demonstrated that the subject device met the predetermined acceptance criteria.
    Thermal SpreadThermal spread testing was performed to evaluate the thermal spread damage produced by the subject and predicate Voyant Open Fusion Devices. Vessels representative of the devices' indications were sealed and measurements of the fused areas were taken. Analysis of the measurements demonstrated that the subject device met the predetermined acceptance criteria.
    Long-term Seal Quality (Preclinical Chronic Survival)A chronic survival study was performed to evaluate long-term seal quality, device performance, and potential for adverse effects on adjacent structures. Vessels representative of the devices' indications were sealed and evaluated for hemostasis and signs of hematoma. The result of the study demonstrated that the subject device met the predetermined acceptance criteria.
    Software VerificationUnit, integration, and system level verification were conducted to evaluate the implementation and performance of the device software script.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The text refers to "vessels representative of the devices' indications" for "Burst pressure testing," "Thermal spread testing," and the "chronic survival study." However, it does not specify the exact sample sizes (e.g., number of vessels, number of animals/subjects) used for these tests. It also does not directly state the data provenance in terms of country of origin or whether the studies were purely retrospective or prospective, though the description of preclinical studies implies a prospective design.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This question is not applicable as this is a physical electrosurgical device, not an AI or diagnostic imaging device that requires expert-established ground truth from medical images. The "ground truth" for this device's performance would be direct measurements (burst pressure, thermal spread, observed hemostasis/hematoma) in laboratory and preclinical settings.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This question is not applicable for the same reasons as #3. Performance was measured objectively.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This question is not applicable as this is not an AI-assisted diagnostic device for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This question is not applicable as this is not an algorithm, but a physical electrosurgical tool operated by a surgeon.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for this device's performance was established through direct physical measurements and observations in benchtop and preclinical animal studies. This includes:

    • Quantitative measurements: Burst pressure (for seal strength), measurements of fused areas (for thermal spread).
    • Qualitative observations: Evaluation for hemostasis and signs of hematoma in the chronic survival study.
    • Compliance with standards: Electrical safety and EMC testing against IEC standards.

    8. The sample size for the training set

    This question is not applicable as this is not an AI/machine learning device requiring a "training set." The verification of the device's software focused on "unit, integration, and system level verification" rather than algorithm training.

    9. How the ground truth for the training set was established

    This question is not applicable as there is no "training set" for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K172624

    Validate with FDA (Live)

    Date Cleared
    2018-02-13

    (165 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Voyant 5mm Fusion device is a bipolar, electrosurgical device indicated for use with the Voyant electrosurgical generator in laparoscopic procedures where the ligation and division of vessels and tissue bundles is desired.

    The device can seal and divide vessels up to and including 7mm in diameter and tissue bundles that can be captured in the jaws of the device.

    The device has not been shown to be effective for tubal coagulation for sterilization procedures, and should not be used for these procedures.

    Device Description

    The Voyant 5mm Fusion device is an advanced bipolar instrument that uses RF energy, provided by the Voyant Electrosurgical Generator (K141288), to seal vessels up to and including 7mm in diameter. The device may also be used to seal tissue bundles that can be captured in the device jaws. The device features a mechanical, user-actuated blade for the division of sealed tissue.

    AI/ML Overview

    The medical device discussed is the Voyant 5mm Fusion Device, an electrosurgical device for laparoscopic procedures to ligate and divide vessels and tissue bundles.

    Here's an analysis of its acceptance criteria and the study that proves it meets them, based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a specific table with numerical acceptance criteria values alongside numerical reported device performance in the traditional sense of a diagnostic AI product. Instead, it describes compliance with standards and the outcome of specific bench tests.

    Acceptance Criteria CategoryReported Device PerformanceStudy Type
    Mechanical SafetyComplies with IEC 60601-1:2005Mechanical Testing
    Electrical SafetyComplies with IEC 60601-1:2005 and IEC 60601-2-2:2009Electrical Safety Testing
    Electromagnetic Compatibility (EMC)Complies with IEC 60601-1-2:2007EMC Testing
    Burst Pressure (Vessel Sealing Strength)Demonstrated that the subject device met the predetermined acceptance criteria (comparison to predicate on vessels up to 7mm).Bench (Burst Pressure Testing)
    Thermal Spread (Local Tissue Damage)Analysis of measurements demonstrated that the subject device met the predetermined acceptance criteria (comparison to predicate).Bench (Thermal Spread Testing)
    Software FunctionalityUnit, integration, and system level verification were conducted to evaluate the implementation and performance of the device software script.Software Verification
    Substantial EquivalenceThe subject device is substantially equivalent in performance to the predicate Voyant 5mm Fusion Device with respect to intended use (i.e. vessel sealing performance and local tissue effects) and does not raise any new issues of safety and efficacy.Overall conclusion based on all tests.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Sample Size for Bench Tests (Burst Pressure & Thermal Spread): The document states "Vessels representative of the devices' indications were sealed" but does not specify the number of vessels or samples used for the burst pressure and thermal spread tests.
    • Data Provenance: Not specified. These are bench tests, so the "data" would be the results from the physical testing of the device on isolated vessels/tissue. Country of origin for such tests is typically the manufacturing or testing facility.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This is not applicable as the device is a surgical instrument, not a diagnostic AI system requiring expert interpretation or ground truth establishment in a clinical sense. The "ground truth" for the performance tests (e.g., burst pressure, thermal spread) are objective measurements taken from the physical properties and effects of the device.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. This device is not an AI diagnostic tool and does not involve human adjudication of results in the way clinical studies often do. The tests performed are objective, measurable physical tests.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The device is a surgical instrument, not an AI diagnostic tool that assists human readers. No MRMC study was mentioned or required.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. The device is a surgical instrument, not an AI algorithm. Its performance is inherent in its electrosurgical capabilities.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for this device's performance is based on objective physical measurements and compliance with established engineering and medical device standards.

    • For burst pressure: The actual pressure at which a sealed vessel ruptures.
    • For thermal spread: Direct measurements of the extent of thermal damage to tissue.
    • For electrical safety and EMC: Compliance with specified international standards (IEC 60601 series).

    8. The sample size for the training set

    Not applicable. This device is a physical electrosurgical instrument, not an AI or machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171684

    Validate with FDA (Live)

    Date Cleared
    2017-08-07

    (61 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Epix Electrosurgical Probe with Smoke Evacuation is intended to deliver energy from an independent monopolar electrosurgical generator to cut and coagulate tissue during laparoscopic surgical procedures where the device is introduced into the body through a cannula. The device may be used for the evacuation of smoke created by electrosurgery at the surgical site.

    Device Description

    The Epix Electrosurgical Probe with Smoke Evacuation is a sterile, single-use monopolar instrument equipped with a smoke evacuation feature. The proposed device uses RF energy provided by a generator to electrosurgically cut and/or coagulate tissue during general laparoscopic procedures. The electrosurgical probes are available in three different tip geometries with probe lengths ranging between 20cm - 45cm. All models are constructed of the same materials and by similar manufacturing assembly processes.

    AI/ML Overview

    This document from the FDA describes the substantial equivalence determination for the "Epix Electrosurgical Probe with Smoke Evacuation" (K171684) compared to a predicate device, the "Epix Electrosurgical Probes" (K132300).

    The provided text does not contain the detailed acceptance criteria or the specific study results in the format requested. It states that certain performance tests were conducted and that the device "Met Acceptance Criteria" or was "Substantially Equivalent," but it does not specify what those criteria were (e.g., a numerical threshold or a specific characteristic being achieved) or the quantitative results of the tests.

    Therefore, I cannot fulfill all parts of your request with the given information. However, I can extract the available information regarding performance data.

    Here's what can be extracted based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    TestReported Device Performance
    Electrosurgical PerformanceSubstantially Equivalent
    Smoke Evacuation PerformanceSubstantially Equivalent
    BiocompatibilityMet Acceptance Criteria
    Mechanical TestingMet Acceptance Criteria
    Electrical Safety TestingMet Acceptance Criteria
    Electromagnetic Compatibility (EMC) TestingMet Acceptance Criteria

    Missing Information: The document does not specify the actual acceptance criteria (e.g., "electrical impedance within X ohms," "smoke evacuation rate of Y L/min") for each test, only that they were met or that the device was substantially equivalent.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not specified.
    • Data Provenance: Not specified. It can be inferred that the testing was conducted by Applied Medical Resources Corporation for this FDA submission, likely within the US, but this is not explicitly stated.
    • Retrospective or Prospective: Not specified. These were likely laboratory-based performance and safety tests rather than clinical studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • This information is not applicable and not provided. The performance tests described (Electrosurgical, Smoke Evacuation, Biocompatibility, Mechanical, Electrical Safety, EMC) are engineering and laboratory-based tests, not clinical evaluations requiring expert interpretation of results for ground truth establishment.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • This information is not applicable and not provided. Adjudication methods are typically used in clinical studies for interpretation of subjective findings. The tests performed are objective performance measurements.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC comparative effectiveness study was done. The device is a physical electrosurgical probe, not an AI-assisted diagnostic tool.
    • The document explicitly states: "No animal or clinical studies were required to demonstrate the safety and efficacy of the subject device in support of this application for premarket clearance."

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • This question is not applicable as the device is a physical electrosurgical probe, not an algorithm or AI system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For the performance tests listed, the "ground truth" would be established by validated test methodologies and engineering specifications, rather than clinical ground truth types like pathology or expert consensus. For example, for electrical safety, the ground truth is adherence to IEC standards. For biocompatibility, it's compliance with ISO 10993 series.

    8. The sample size for the training set

    • This information is not applicable as the device is a physical electrosurgical probe, not a machine learning or AI device that requires a training set.

    9. How the ground truth for the training set was established

    • This information is not applicable for the same reason as above.