Search Filters

Search Results

Found 7 results

510(k) Data Aggregation

    K Number
    K250499

    Validate with FDA (Live)

    Date Cleared
    2025-04-17

    (56 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB is indicated for use in pediatric (including neonates and infants) and adult patients to hydrolyze fats during enteral feeding.

    Device Description

    RELiZORB® is a point-of-care device designed to fit in-line with currently used enteral feeding circuits. RELiZORB functions to hydrolyze (break down) fats present in formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. Formulas are liquid food products that are specially formulated and designed to increase the amount of various food elements and nutrients that will maintain proper physiological function of the body. The breakdown of fats by RELiZORB is intended to mimic the function of the enzyme pancreatic lipase. RELiZORB is comprised of a cylindrical, hollow cartridge with a single inlet port and a single outlet port connection. Inside the cartridge, there are small white beads. The digestive enzyme, lipase, is covalently bound to the small white beads. The lipase-bead complex, iLipase® (immobilized lipase), is retained within the cartridge during use by filters on both ends of the cartridge. The fat in formulas is hydrolyzed when it encounters iLipase as the formula passes through the cartridge.

    AI/ML Overview

    The provided FDA 510(k) clearance letter describes a device called RELiZORB, an enzyme packed cartridge designed to hydrolyze fats in enteral feeding formulas. The clearance is for an updated indication for use to include neonates and infants.

    The document does not contain acceptance criteria in the traditional sense of specific performance metrics (e.g., accuracy, sensitivity, specificity, or fat hydrolysis rate thresholds) that the device must meet, nor does it provide a study that explicitly demonstrates the device's performance against such criteria.

    Instead, the submission focuses on demonstrating substantial equivalence to a previously cleared predicate device (K243284) and expanding the indications for use based on Real-World Evidence (RWE) and functional performance testing with infant formulas.

    Here's an breakdown of the information provided, categorized according to your request, with a clear statement where information is not present in the document.


    Analysis of Acceptance Criteria and Device Performance Study for RELiZORB (K250499)

    The 510(k) clearance for RELiZORB (K250499) primarily addresses an expansion of its Indications for Use to include neonates and infants, building upon its previous clearance (K243284). The submission aims to demonstrate that this expanded use introduces no new questions of safety or effectiveness and maintains substantial equivalence to the predicate device.

    Crucially, the provided document does not detail specific quantitative acceptance criteria (e.g., specific thresholds for fat hydrolysis rates) that RELiZORB had to meet for this clearance, nor does it present a formal clinical study with performance outcomes against such criteria. The evidence presented is largely qualitative and focused on the safety and functional compatibility of the device with infant formulas and its historical safety profile in a real-world setting.

    1. Table of Acceptance Criteria and Reported Device Performance

    As stated above, the document does not provide a table of acceptance criteria with corresponding device performance metrics in the manner of a typical analytical or clinical performance study for a diagnostic or AI device. The "performance" discussed is related to "functional performance... compatible with commercially available infant formulas" and a review of post-market surveillance data for safety. No quantitative outcomes (e.g., specific fat hydrolysis percentages) are reported as acceptance criteria or performance metrics in this document.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set (Real-World Data):
      • Sample Size: "multiple data outputs in Medical Records for patients initiating RELiZORB use between ages <1 year". The exact number of patients is not specified beyond "patients, <1 year, received formula... at more than 60 centers across the US."
      • Data Provenance:
        • Country of Origin: United States ("60 centers across the US").
        • Retrospective or Prospective: Retrospective observational study.
        • Time Period: January 16, 2020 to October 31, 2024.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • The document does not describe the use of experts to establish a "ground truth" for the retrospective observational study.
    • The data analyzed were "Medical Records" and "Post Market Surveillance data," which likely reflect standard clinical practice and reported adverse events rather than expert-adjudicated ground truth for a specific diagnostic outcome.

    4. Adjudication Method for the Test Set

    • Not Applicable: Given that the study was a retrospective observational review of medical records and post-market surveillance data, there is no mention of an adjudication method (e.g., 2+1, 3+1 consensus) for establishing ground truth or evaluating device performance. The focus was on safety and compatibility over a defined performance metric.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No, an MRMC comparative effectiveness study was not done. This type of study is typically relevant for diagnostic imaging AI devices where human reader performance is being evaluated with or without AI assistance. RELiZORB is an enzyme-packed cartridge for fat hydrolysis, not a diagnostic imaging AI.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    • Not Applicable in the AI/Software context: RELiZORB is a physical medical device (enzyme-packed cartridge), not a software algorithm or AI. Therefore, a "standalone algorithm performance" study as typically understood for AI/software devices is not relevant.
    • However, the document does mention "RELiZORB functional performance was evaluated and found to be compatible with commercially available infant formulas." This can be considered a "standalone" evaluation of the device's functional capability, but specific methodology and quantitative results are not provided in this document.

    7. Type of Ground Truth Used

    • Implicit "Ground Truth": The "ground truth" for the retrospective observational study was based on real-world patient outcomes reported in medical records and post-market surveillance data (complaints) for safety and "effectiveness" (implied functional compatibility and lack of adverse events). It was not based on expert consensus, pathology, or specific outcomes data regarding fat absorption, but rather on the overall clinical experience and safety profile in the real world.
    • For the "functional performance" evaluation, the ground truth would be the actual fat hydrolysis achieved by the device when tested with infant formulas in a lab setting, but these specific results are not detailed.

    8. Sample Size for the Training Set

    • Not Applicable: As this is a physical device and not an AI/Machine Learning model, there is no concept of a "training set" in the conventional sense for this submission.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable: Since there is no training set for an AI model, this information is not relevant.

    Summary of Study and Evidence Presented:

    The submission for K250499 does not present a typical performance study with pre-defined acceptance criteria (e.g., accuracy, sensitivity, or specific hydrolysis rates). Instead, it makes a case for substantial equivalence and expanded indication based on:

    1. Identity with Predicate Device: The subject device is identical in design, materials, and principle of operation to the cleared predicate device.
    2. Real-World Evidence (RWE): A retrospective observational study of RELiZORB use in patients <1 year old (neonates and infants) in real-world clinical settings, analyzing medical records. The key outcome from this RWE was that RELiZORB use in this population was deemed "safe and effective," seemingly based on the absence of new or significant safety concerns.
    3. Post-Market Surveillance Data Review: A review of complaint data from the existing marketed device (predicate) when used in the <1-year-old population showed "no newly identified complaints."
    4. Functional Performance Evaluation: The device's functional performance was evaluated for compatibility with commercially available infant formulas. The results are reported qualitatively as "found to be compatible."

    The "acceptance criteria" appear to be implicit: that the device's use in neonates and infants (with the specific cartridge limits specified) would not introduce new safety or effectiveness concerns, and that its functional compatibility with infant formulas was confirmed. This approach aligns with the FDA's guidance on using Real-World Evidence to support regulatory decision-making for medical devices, particularly when expanding indications for a device that already has a established safety and performance profile.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243284

    Validate with FDA (Live)

    Date Cleared
    2025-01-15

    (90 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB is indicated for use in pediatric (ages 1 year and above) and adults patients to hydrolyze fats in enteral formula.

    Device Description

    RELiZORB® is a point-of-care device designed to fit in-line with currently used enteral feeding circuits. RELiZORB functions to hydrolyze (break down) fats present in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This breakdown of fats by RELiZORB is intended to mimic the function of the enzyme pancreatic lipase. RELiZORB is comprised of a cylindrical, hollow cartridge with a single inlet port and a single outlet port connection. Inside the cartridge, there are small white acrylic beads. The digestive enzyme, lipase, is covalently bound to the small white beads. The lipase-bead complex, iLipase® (immobilized lipase), is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed when it comes in contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    The provided text is a 510(k) summary for the RELiZORB device. It details various aspects of the device, its intended use, and substantial equivalence to a predicate device. However, it does not contain a typical acceptance criteria table with reported device performance metrics in the format usually associated with diagnostic device evaluation (e.g., sensitivity, specificity, accuracy).

    Instead, the submission focuses on extending the Indications for Use for the RELiZORB device to include pediatric patients aged 1 year and above, compared to the previous indication of 2 years and above. The "acceptance criteria" in this context are primarily related to demonstrating that this change in indication does not introduce new safety or effectiveness concerns, and that the device remains substantially equivalent to the predicate.

    Here's an analysis of the "acceptance criteria" and the study that supports the change, based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not present a formal table of acceptance criteria with specific performance metrics (like sensitivity, specificity, or AUC) as one might expect for a diagnostic AI/ML device. Instead, the acceptance criteria for extending the age indication are implicitly:

    • Safety: The device is safe for use in pediatric patients aged 1 to <2 years. This is "accepted" if post-market surveillance shows no new safety concerns in this age group.
    • Effectiveness: The device is effective in hydrolyzing fats in enteral formula for pediatric patients aged 1 to <2 years. This is "accepted" if real-world data demonstrates effectiveness in this population.
    • Substantial Equivalence: The device, with the updated indication, remains substantially equivalent to the predicate device (K232784) and raises no new questions of safety and effectiveness.

    Reported Device Performance:

    • Safety: The submission states "post-market surveillance of product complaints data supports the safety of RELiZORB in this age group." No specific numbers or detailed adverse event rates are provided in this summary.
    • Effectiveness: The submission states, "These Real-World Data support the Real-World Evidence that device use in this population is effective." No specific quantitative effectiveness metrics (e.g., percentage of fat hydrolyzed, patient nutritional outcomes) are provided in this summary. The primary function of the device (hydrolyzing fats) is assumed to be consistent across the age range based on its mechanism of action and the lack of change in device design.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: The document mentions a "retrospective observational study" that "evaluated multiple data outputs in Medical Records for patients initiating RELiZORB use between ages 1 and <2 years." However, the specific sample size (i.e., number of patients) is not provided in the summary.
    • Provenance: The study was "retrospective observational." The country of origin is not specified, though Alcresta Therapeutics is based in Waltham, Massachusetts, USA. The data is described as "Real-World Data" from "Medical Records."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable to the type of study conducted. The study is a retrospective observational study using real-world data from medical records and post-market surveillance. It does not involve expert readers establishing ground truth for diagnostic interpretations in the way an AI/ML diagnostic study would. The "ground truth" here would be clinical observations of safety and effectiveness from actual patient usage, rather than expert-labeled diagnostic findings.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable. There was no expert "adjudication" in the traditional sense for a diagnostic test set. The study reviewed medical records and post-market surveillance data.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable. The RELiZORB device is an enzyme-packed cartridge, not an AI/ML diagnostic device that would assist human readers in interpretation. Therefore, no MRMC study or AI assistance effect size is discussed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable. The RELiZORB device is a medical device (an enzyme cartridge), not an algorithm. Its performance is inherent to its physical function.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for demonstrating safety and effectiveness in the 1 to <2 year old age group was based on:

    • Real-World Data/Evidence: Derived from "Medical Records" and "multiple data outputs" for patients using RELiZORB.
    • Post-market Safety Surveillance: Product complaints data.

    This broadly falls under outcomes data and safety monitoring data collected in a real-world setting.

    8. The sample size for the training set

    This is not applicable as the device is not an AI/ML algorithm requiring a training set in the typical sense. The device's function is mechanistic (enzyme hydrolysis), and its initial design and validation would have involved laboratory and pre-clinical testing, not "training data" for a machine learning model.

    9. How the ground truth for the training set was established

    This is not applicable for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232784

    Validate with FDA (Live)

    Device Name
    RELiZORB®
    Date Cleared
    2023-12-21

    (101 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB® is indicated for use with pediatric (ages 2 years and above) and adult patients to hydrolyze fats in enteral formula.

    Device Description

    RELiZORB® is a single-use, point-of-care digestive enzyme cartridge that connects in-line with existing enteral feeding circuits. RELiZORB is designed to hydrolyze (digest) fats contained in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This hydrolysis of fats by RELiZORB is intended to mimic the function of the digestive enzyme lipase in patients. RELiZORB is comprised of a clear cylindrical, plastic cartridge with a single inlet connection port and a single outlet connection port. Inside the cartridge, there are small white beads covalently bonded to the digestive enzyme, lipase. This lipase-bead complex, iLipase™ (immobilized lipase) is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed upon contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    This document is a 510(k) summary for the RELiZORB® device, which is an enzyme-packed cartridge used to hydrolyze fats in enteral formula. It is a submission to the FDA seeking clearance for a modified version of an already cleared device.

    The provided text focuses on demonstrating the substantial equivalence of the subject device (RELiZORB® K232784) to its predicate device (RELiZORB® K231156). It does not contain information about the acceptance criteria and study proving performance for an AI/Software as a Medical Device (SaMD).

    Specifically, the document does not contain the following information typically found in acceptance criteria and study designs for AI/SaMD devices:

    • A table of acceptance criteria and reported device performance (for an AI/SaMD)
    • Sample sizes used for a test set (as would be used for an AI/SaMD model's performance evaluation)
    • Data provenance for a test set
    • Number of experts and qualifications for ground truth establishment
    • Adjudication method for a test set
    • MRMC comparative effectiveness study details
    • Standalone (algorithm-only) performance results
    • Type of ground truth used (e.g., pathology, outcomes data)
    • Sample size for the training set (for an AI/ML model)
    • How ground truth for the training set was established

    Instead, the document details performance testing related to the physical and chemical characteristics of the RELiZORB® cartridge, which is a hardware medical device with an enzymatic function.

    Here's a breakdown of the performance testing cited for this hardware device, which is different from "acceptance criteria" for an AI/SaMD:

    Overview of Performance Testing for RELiZORB® (Hardware Device):

    The performance testing listed is geared towards a physical device with a biological function (enzyme action). The "acceptance criteria" for this device would therefore relate to its physical integrity, chemical activity, and biocompatibility, rather than diagnostic accuracy or algorithmic performance.

    1. Table of "Acceptance Criteria" (Inferred from Performance Testing) and Reported Device Performance:

    The document lists categories of testing rather than specific numerical acceptance criteria or detailed results. However, we can infer some "acceptance criteria" that would be met by these tests:

    Acceptance Criteria Category (Inferred)Specific Tests Performed (from text)Reported Device Performance (General Statement)
    BiocompatibilityBiocompatibility testing (Sections 15, 19)Device causes neither an adverse tissue response nor adverse performance.
    Device Integrity/DurabilityInternal and external appearance, Pouch integrity, Physical/Mechanical Testing (Filter tensile strength, Weld tensile strength, Filter integrity/bead retention), Ship testingDemonstrated to withstand clinical forces, maintain integrity, and retain beads.
    Enzymatic FunctionHydrolysis, Demonstration of enzymatic effect on intended macronutrientHydrolyzes fats in enteral formula from triglycerides into fatty acids and monoglycerides.
    Enzyme RetentionUnconjugated protein, Amount of enzyme that exits the cartridge (Section 10)Enzyme is retained within the cartridge during use by filters; amount exiting the cartridge is characterized.
    Flow DynamicsFlow rate and leakage testing, Validation that the device does not impede flow alarms on enteral feeding pumps (Sections 18 & 14)Does not impede the flow of enteral formula or flow alarms on enteral feeding pumps.
    Nutritional ImpactValidation that the device does not adversely impact the nutritional composition of enteral formula (Section 18)Does not adversely impact the nutritional composition.
    Shelf LifeEvaluation of product shelf life, Performance data to support shelf life by demonstrating package integrity and device functionality over the identified shelf life (Section 14)Functionality and integrity maintained over identified shelf life.
    Safety in UseHuman factors testing (Section 10), Preclinical Studies in porcine modelRisks characterized; safety and efficacy assessed, including impact on fat absorption and weaning from parenteral to enteral nutrition.
    Labeling RequirementsLabeling (Section 13)Labeling includes required summaries, instructions, warnings, and patient information.

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not applicable in the context of an AI/ML test set. For physical and chemical tests, typically specific numbers of units are tested according to standard protocols (e.g., n=3, n=5, n=10 per batch), but these specific numbers are not provided in the summary.
    • Data Provenance: The preclinical studies were conducted in a porcine model. The document does not specify the country of origin for the studies, nor whether they were retrospective or prospective, though preclinical animal studies are typically prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as this is not an AI/ML diagnostic device requiring human expert ground truth for interpretation of imaging or other complex data. The "ground truth" for this device's performance would be the scientific measurement of its physical properties and chemical activity (e.g., fat hydrolysis percentage).

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    • Not applicable. Adjudication methods are relevant for human interpretation or consensus in diagnostic studies, not for the performance testing of a physical medical device.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. This is not an AI-assisted diagnostic device, so an MRMC study is not relevant or performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • No. This is a physical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For this device, the "ground truth" for its performance is established through standard laboratory testing for:
      • Chemical Analysis: Measuring the hydrolysis of fats (e.g., quantifying fatty acids and monoglycerides produced).
      • Physical Measurements: Tensile strength, flow rates, bead retention, appearance.
      • Biological Testing: Biocompatibility tests (e.g., cytotoxicity, sensitization), and in vivo animal studies (porcine model) to assess safety and efficacy (fat absorption, impact on parenteral nutrition weaning).

    8. The sample size for the training set:

    • Not applicable. This is not an AI/ML device that requires a "training set."

    9. How the ground truth for the training set was established:

    • Not applicable.

    In summary: The provided text details the regulatory clearance process for a physical medical device (enzyme-packed cartridge), not an AI/Software as a Medical Device (SaMD). Therefore, the criteria and study types described in the prompt (which are typical for AI/SaMD) are not present in this document. The "performance data" here refers to standard engineering, chemical, and biological testing of a hardware product.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231156

    Validate with FDA (Live)

    Date Cleared
    2023-08-30

    (128 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB® is indicated for use with pediatric (ages 2 years and above) and adult patients to hydrolyze fats in enteral formula.

    Device Description

    RELiZORB® is a single-use, point-of-care digestive enzyme cartridge that connects in-line with existing enteral feeding circuits. RELiZORB® is designed to hydrolyze (digest) fats contained in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This hydrolysis of fats by RELiZORB® is intended to mimic the function of the digestive enzyme lipase in patients who do not excretesufficient levels of the lipase enzyme. RELiZORB® is comprised of a clear cylindrical, plastic cartridge with a single inlet connection port and a single outlet connection port. Inside the cartridge, there are small white beads that the digestive enzyme, lipase, is covalently bound to. The lipase-bead complex, iLipase™ (immobilized lipase) is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed as it comes in contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the RELiZORB® enzyme packed cartridge. This submission is primarily focused on updating the indications for use to include pediatric patients aged 2 years and above, extending from the previous clearance for 5 years and above. The core device (RELiZORB®) itself has not changed technologically since its previous clearance (K191379).

    Here's an analysis of the acceptance criteria and the study that proves the device meets those criteria, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of quantitative acceptance criteria for device performance. Instead, it states that the technological characteristics, design, materials composition, principal of operation, and all other features of RELiZORB® have not changed since the clearance of K191379. Therefore, the device performance is assumed to be consistent with the performance demonstrated for the predicate device.

    The primary "acceptance criterion" addressed in this specific submission is the safety and effectiveness of the device for a younger pediatric population (2-5 years old). The device's performance in terms of fat hydrolysis would be the same as previously established.

    Regarding the expanded indication for use:

    Acceptance Criterion (Implicit)Reported Device Performance
    Safety and effectiveness for pediatric patients aged 2-5 years"This Real World Data supports the Real World Evidence that use in this use population is both safe and effective." (Based on a retrospective registry study evaluating multiple data outputs in Electronic Medical Records (EMRs) for patients in this age group who had been prescribed RELiZORB®).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: The document states that the retrospective registry study "evaluated multiple data outputs in Electronic Medical Records (EMRs) for patients between ages 2 year and 5 years to whom RELiZORB® had been prescribed to them." However, the exact sample size (number of patients) used in this retrospective study is not specified.
    • Data Provenance: The data is described as "Real World Data" from "Electronic Medical Records (EMRs)". The specific country of origin is not mentioned, but given the FDA submission, it's highly likely to be U.S. data. The study is explicitly described as retrospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not describe the use of experts to establish ground truth for this particular retrospective registry study. The study appears to rely on clinical outcomes and data from Electronic Medical Records, implying that the "ground truth" concerning safety and effectiveness in the 2-5 year old population was derived from the real-world clinical experience and documentation within those EMRs.

    4. Adjudication Method for the Test Set

    No adjudication method is described. The retrospective EMR data analysis would likely involve data extraction and analysis by the submitting company, Alcresta Therapeutics, Inc.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    This section is not applicable as the device is an enzyme packed cartridge, not an AI or imaging diagnostic device that involves human readers or an AI assistance component.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This section is not applicable. The RELiZORB® is a physical device that performs a chemical function (fat hydrolysis), not an algorithm.

    7. The Type of Ground Truth Used

    The ground truth for the expanded indication of use (safety and effectiveness in 2-5 year olds) was established through Real World Evidence (RWE) derived from Real World Data (RWD), specifically "multiple data outputs in Electronic Medical Records (EMRs)" reflecting actual clinical outcomes and experiences of patients who had already used the device.

    8. The Sample Size for the Training Set

    There is no mention of a "training set" in the context of this submission. The device itself (enzyme cartridge) is not a machine learning model that requires a training set. The retrospective registry study is analyzing existing real-world data to support an expanded indication for use, not to train a device or algorithm.

    9. How the Ground Truth for the Training Set Was Established

    This section is not applicable as there is no training set for the device itself or a machine learning component.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191379

    Validate with FDA (Live)

    Device Name
    RELiZORB
    Date Cleared
    2019-12-04

    (195 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB™ is indicated for use with pediatric (ages 5 years and above) and adult patients to hydrolyze fats in enteral formula.

    Device Description

    RELiZORB is a single-use, point-of-care digestive enzyme cartridge that connects in-line with existing enteral feeding circuits. RELiZORB is designed to hydrolyze (digest) fats contained in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This hydrolysis of fats by RELiZORB is intended to mimic the function of the digestive enzyme lipase in patients who do not excr ete sufficient levels of the lipase enzyme. RELiZORB is comprised of a clear cylindrical, plastic cartridge with a single inlet connection port and a single outlet connection port. Inside the cartridge, there are small white beads. The digestive enzyme, lipase, is covalently bound to the small white beads. The lipasebead complex, iLipase™ (immobilized lipase), is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed as it comes in contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the RELiZORB device, based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state "acceptance criteria" with numerical targets for each performance metric for the subject device (K191379), but rather implies equivalence to a predicate device. The performance data listed are the types of tests conducted to demonstrate this equivalence. The "Reported Device Performance" for the subject device is simply that it met the equivalence requirements for these tests. The predicate device's performance would have established the original acceptance criteria.

    Performance MetricImplied Acceptance Criteria (via Predicate Equivalence)Reported Device Performance (Subject Device)
    Pouch seal/tensile/visual testingMet predicate specificationsDemonstrated equivalence
    Primary pouch ship testing (ISTA 2A)Met predicate specificationsDemonstrated equivalence
    Filter integrity performanceMet predicate specificationsDemonstrated equivalence
    HydrolysisFunctionally equivalent to predicateDemonstrated equivalence
    Flow rateFunctionally equivalent to predicateDemonstrated equivalence
    Leak testingMet predicate specificationsDemonstrated equivalence

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify a distinct "test set" sample size or data provenance (e.g., country of origin, retrospective/prospective) for a clinical study. The performance data focuses on non-clinical testing of the device itself (e.g., integrity, flow, hydrolysis), rather than clinical outcomes with human subjects.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    Not applicable. This device is an enzyme-packed cartridge for hydrolyzing fats in enteral formula. The "ground truth" would be objective measurements of its physical and chemical properties and its ability to break down fats, not a diagnostic interpretation by human experts.

    4. Adjudication Method for the Test Set

    Not applicable, as no human expert adjudication is involved in the technical performance testing described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. The document describes non-clinical performance testing for a device that acts on enteral formula. It focuses on the device's functional equivalence to a predicate, not on human reader performance with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, in a way. The testing described is "standalone" in the sense that it evaluates the device's performance (hydrolysis, flow rate, integrity) directly, without human interaction during the measurement process. However, this is not an "algorithm-only" performance as the device is a physical product, not a software algorithm.

    7. The Type of Ground Truth Used

    The ground truth used is primarily based on objective physical and chemical measurements of the device's performance, such as:

    • Measurement of seal strength, tensile strength, visual inspection results for pouch testing.
    • Results from standardized shipping tests (ISTA 2A).
    • Quantitative measurements of filter integrity.
    • Biochemical assays to measure the extent of fat hydrolysis.
    • Measurements of fluid flow rate through the cartridge.
    • Leak detection methods.

    These measurements are compared against established specifications for the predicate device to demonstrate equivalence.

    8. The Sample Size for the Training Set

    Not applicable. This device is a physical product, not an AI/ML algorithm that requires a "training set." The development would involve engineering and materials science, not machine learning training.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163057

    Validate with FDA (Live)

    Device Name
    Relizorb
    Date Cleared
    2017-07-12

    (253 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB™ is indicated for use in pediatric patients (ages 5 years and above) and adult patients to hydrolyze fats in enteral formula.

    Device Description

    RELiZORB is a single-use, point-of-care digestive enzyme cartridge that connects in-line with existing enteral feeding circuits. RELiZORB is designed to hydrolyze (digest) fats contained in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This hydrolysis of fats by RELiZORB is intended to mimic the function of the digestive enzyme lipase in patients who do not excr ete sufficient levels of the lipase enzyme. RELiZORB is comprised of a clear cylindrical, plastic cartridge with a single inlet connection port and a single outlet connection port. Inside the cartridge, there are small white beads. The digestive enzyme, lipase, is covalently bound to the small white beads. The lipase-bead complex, iLipaseTM (immobilized lipase), is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed as it comes in contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    This document is a 510(k) summary for the RELiZORB™ device, submitted by Alcresta Therapeutics, Inc. The purpose of the submission is to expand the indications for use to include pediatric patients (ages 5 years and above) and to update the shelf life. The device, an enzyme-packed cartridge, is designed to hydrolyze fats in enteral formulas.

    Here's an analysis of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state "acceptance criteria" in a quantitative format for the clinical study. However, it describes the outcomes and findings from the clinical study that supported the expanded indication. For shelf life, it generally states "Shelf life test results support labeled shelf life of RELiZORB," implying that the performance met internal criteria.

    Acceptance Criteria (Inferred from study outcomes)Reported Device Performance
    Safety and Tolerability (evaluated through GI symptoms and adverse events) in pediatric and adult patients with CFThe most commonly reported GI events were abdominal pain, gas and bloating, while the most common non-gastrointestinal adverse event reported was headache. The implication is that these were acceptable given the patient population and the overall context of the study.
    Efficacy in fat absorption (measured by plasma concentrations of LCPUFAs like DHA and EPA) in pediatric and adult patients with CFRELiZORB use resulted in a 2.8-fold change in plasma concentrations of physiologically relevant long-chain polyunsaturated fatty acids (LCPUFAs) such as DHA and EPA, as measured by plasma absorption kinetics and bioavailability profile (Area Under the Curve - AUC). Additionally, there was a 2.1-fold change in peak plasma concentrations (Cmax) of DHA and EPA. These results confirmed previous findings in a porcine model.
    Shelf Life (tensile, mechanical strength, flow rate, hydrolysis, microbiological testing)"Shelf life test results support labeled shelf life of RELiZORB." (Specific numerical acceptance criteria and performance values are not provided in this summary).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set (Clinical Study): 33 evaluable patients completed the study (from an initial enrollment of 35 patients; 2 withdrew before exposure).
    • Data Provenance: The study was a "multicenter, randomized, double-blind, placebo-controlled crossover clinical study in adult and pediatric patients with cystic fibrosis (CF)." While the specific country of origin is not explicitly stated, "multicenter" implies multiple sites, likely within the United States given the FDA submission. The study design is prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This type of information is not applicable to this device and study. The RELiZORB device is an enzyme-packed cartridge; its "ground truth" for performance is based on biochemical hydrolysis of fats and physiological absorption, not subjective expert interpretation of images or other data that require inter-rater agreement. The "ground truth" for efficacy was established through objective biochemical markers (LCPUFAs in plasma).

    4. Adjudication Method for the Test Set

    This is not applicable as the outcome measures (LCPUFA concentrations, adverse events) are objective and do not require adjudication by experts in the way clinical images or diagnoses might.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This is not applicable. The RELiZORB is a medical device (enzyme-packed cartridge), not an AI-powered diagnostic or assistive technology for human readers.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This is not applicable. The RELiZORB is a physical device, not an algorithm. Its performance is inherent to its enzymatic activity.

    7. The Type of Ground Truth Used

    For the clinical study, the ground truth for device efficacy was established using outcome data:

    • Plasma absorption kinetics and bioavailability profile (Area Under the Concentration Time Curve - AUC) of physiologically relevant long-chain polyunsaturated fatty acids (LCPUFAs) like DHA and EPA.
    • Peak plasma concentrations (Cmax) of DHA and EPA.
    • Gastrointestinal (GI) symptoms and non-GI adverse events for safety and tolerability.

    8. The Sample Size for the Training Set

    This is not applicable to the RELiZORB device. The device is not learning or being trained in a computational sense. Its design and enzymatic function are pre-defined.

    9. How the Ground Truth for the Training Set Was Established

    This is not applicable for the same reasons as #8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K161247

    Validate with FDA (Live)

    Device Name
    Relizorb
    Date Cleared
    2016-06-30

    (58 days)

    Product Code
    Regulation Number
    876.5985
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    RELiZORB™ is indicated for use in adults to hydrolyze fats in enteral formula

    Device Description

    The RELiZORB device is a point-of-care accessory designed to fit in line with currently used enteral feeding circuits. RELiZORB is designed to hydrolyze (break down) fats present in enteral formulas from triglycerides into fatty acids and monoglycerides to allow for their absorption and utilization by the body. This breakdown of fats by the RELiZORB is intended to mimic the function of the enzyme lipase in patients who do not excr ete sufficient levels of pancreatic lipase. RELiZORB is comprised of a cylindrical, hollow cartridge with a single inlet port and a single outlet port connection. Inside the cartridge, there are small white beads. The digestive enzyme, lipase, is covalently bound to the small white beads. The lipase-bead complex, iLipaseTM (immobilized lipase), is retained within the cartridge during use by filters on both ends of the cartridge. The fat in enteral formulas is hydrolyzed as it comes in contact with iLipase as the formula passes through the cartridge.

    AI/ML Overview

    This document describes a 510(k) premarket notification for the RELiZORB™ device, an enzyme-packed cartridge designed to hydrolyze fats in enteral formula. The submission aims to demonstrate substantial equivalence to a previously cleared RELiZORB™ device (DEN150001).

    Since this is a submission for an enzyme-packed cartridge and not a diagnostic AI/ML device, the detailed questions about acceptance criteria, test sets, ground truth establishment, expert adjudication, and comparative effectiveness studies as typically applied to AI/ML software are not directly applicable in the same manner. This submission focuses on the chemical and mechanical performance of the device rather than the diagnostic accuracy of an algorithm.

    However, I can extract the relevant performance data and criteria mentioned in the document in the spirit of your request:


    1. Table of acceptance criteria and the reported device performance:

    Acceptance Criteria CategorySpecific Criteria (Implicitly Met)Reported Device Performance
    Shelf LifeProduct stability over time, retaining intended function."Shelf life testing of RELIZORB was completed and met the acceptance criteria in the protocol. The shelf life test results support the proposed edit to the labeling with respect to product stability."
    Device PerformanceDevice performs as intended under anticipated conditions of use."The RELIZORB device was previously tested to demonstrate that the device performs as intended under anticipated conditions of use, and safety, including: Tensile and mechanical strength, Flow rate, Demonstration of enzymatic effect on macronutrients, Impurities/degradants characterization, Animal testing to demonstrate hydrolysis effect, Human factors testing." (These tests were deemed sufficient for the predicate device and are implicitly accepted for the current device due to no changes in design, technology, or functionality).
    SafetyNo significant changes to risk assessment due to proposed minor labeling change."The Risk management file was reviewed and there was no significant change to the risk assessment as a result of the proposed minor change to the labeling."
    Quality System ComplianceCompliance with medical device quality system regulations."Alcresta develops and manufactures RELIZORB in compliance with the Quality System regulations (21 CFR 820)."
    BiocompatibilityBiological safety of materials in contact with the body/formula.Referenced standard: ISO 10993-1:2009/Cor 1:2010 Biological evaluation of medical devices. (Implicitly met through prior testing of predicate).
    Usability/Human FactorsDevice is safe and effective for users.Referenced standard: EN 62366:2008 Medical devices - Application of usability engineering. (Implicitly met through prior testing of predicate).
    Risk ManagementApplication of risk management processes.Referenced standard: EN ISO 14971:2012 Medical devices. Application of risk management. (Implicitly met through prior testing of predicate and current review).
    Packaging/ShippingDevice integrity maintained during transport.Referenced standard: ISTA 2A: Packaged-Products weighing 150 lb (68 kg) or Less. Basic Requirements: atmospheric conditioning, compression, fixed displacement or random vibration and shock testing. (Implicitly met through prior testing of predicate).
    Connectors/AdaptersCompatibility and safety of enteral feeding set adapters and connectors.Referenced standard: AAMI/ANSI ID54: 1996/(R)2012: Enteral feeding set adapters and connectors. (Implicitly met through prior testing of predicate).
    Controlled EnvironmentsManufacturing in appropriate environments.Referenced standard: ISO-14644: Cleanrooms and associated controlled environments. (Implicitly met through prior manufacturing of predicate).

    2. Sample size used for the test set and the data provenance:

    • Test set sample size: Not explicitly stated for each specific performance test (tensile, flow rate, enzymatic effect, etc.). The document mentions "shelf life testing" was completed, but not the number of units or replicates. For prior testing of the predicate device, it indicates a range of tests were performed, but no numbers of devices tested are provided.
    • Data provenance: Not explicitly stated (e.g., country of origin). The testing seems to have been conducted by or for Alcresta Therapeutics, Inc. (Newton, MA, USA). The studies appear to be prospective as they involve testing the device under various conditions.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable in the typical sense for this device. This device is not a diagnostic tool requiring expert interpretation of results for ground truth. The "ground truth" for this device would be established by objective measurements of its physical properties (tensile strength, flow rate) and chemical activity (enzymatic effect on macronutrients), likely performed by laboratory technicians or engineers following validated protocols, rather than expert interpretation of a diagnostic outcome.

    4. Adjudication method for the test set:

    • Not applicable. Adjudication methods like 2+1 or 3+1 are used to reconcile disagreements among human readers in diagnostic studies. For this device, performance is evaluated against objective, measurable criteria and laboratory standards.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is not an AI/ML diagnostic device and does not involve human readers interpreting cases with or without AI assistance.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used:

    • For the enzymatic effect: Objective chemical measurements (e.g., measuring the breakdown of triglycerides into fatty acids and monoglycerides).
    • For mechanical/physical properties: Engineering measurements against established standards (e.g., tensile strength, flow rate).
    • For biocompatibility: Laboratory testing results compared to biological safety standards.

    8. The sample size for the training set:

    • Not applicable. This device does not use an algorithm that requires a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. As there is no training set for an algorithm, there is no ground truth to be established for it.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1