Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K955412

    Validate with FDA (Live)

    Date Cleared
    1996-05-14

    (169 days)

    Product Code
    Regulation Number
    884.1720
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The A.S.D. Surgical Trocar is intended for use during vascular and gynecological laparoscopy and other abdominal procedures, to create an entry point for laporascopic instruments into the abdominal cavity. Surgical instruments of the appropriate size can be safely quided and entered into the abdominal cavity through the cannula.

    Device Description

    The A.S.D. Surgical Trocar is a single-use, sterile, temporary, disposable device intended for use during laparoscopy, to create an entry point for laporascopic into the abdominal cavity. Surgical instruments of the appropriate size can be safely guided and entered into the abdominal cavity through the cannula. The Trocar consists of: 1) an obturator with a pointed pyramidal tip, 2) a spring-baded safety shield to of the obturator after lissue penetration. 3) a radiolucent cannula (sleeve) with a gasket system to prevent leakage of gas during i setion and withdrawal of instruments 4) an accessory stability thread to help secure the cannula in the body during use. An collional accessory, an obturator adapter is available to be used as a reducer with the 1011mm system. When the adapter is used, 5 mm instruments are accepted into the 10/11mm trocar. The A.S.D. Trocar is available in the 10/11mm and 5mm sizes. The size of the size of the size of the instrument that can be entered in the trocar. The sleeve lengths available for the 1011mm and 150mm; and for the 5mm trocar are 70 mm and 100mm. The stability threads are available in 38 mm and 51 mm lengths. The A.S.D. Trocar is made of aluminum, stainless steel, polycarbonate and silicone rubber.

    AI/ML Overview

    This document is a 510(k) summary for a surgical device (A.S.D. Safety Trocar) and not an AI/ML device. Therefore, the requested information about acceptance criteria, study design, and ground truth in the context of AI/ML performance is not applicable to this submission.

    The document describes a physical surgical instrument and focuses on its description, intended use, contraindications, and substantial equivalence to existing devices, as required for FDA 510(k) clearance for conventional medical devices.