510(k) Data Aggregation

    K Number
    K040735

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2004-05-21

    (60 days)

    Product Code
    Regulation Number
    878.4580
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ALM X'Ten™ (X10) Surgical Light Systems with Energix™ Power Supply are intended to be used to provide visible illumination of the surgical area or the patient.

    An optional "LEDinside" feature is available and produces lower intensity levels of illumination intended for minimally invasive surgeries, procedures and examinations.

    The Energix™ Power Supply is intended for use with surgical light systems.

    Device Description

    The ALM X'Ten'M Surgical Light System is a new product designation intended to identify a family of surgical lights that will use a similar set of design principals as the Angenieux (AX) Series Surgical Light Systems. The primary predicate device focuses on comparisons to the Angenieux® AX10, which is the medium sized lighthead within the Angenieux® (AX) Series.

    The ALM X'Ten™ Surgical Light provides a broadened set of features and options that include video camera and flat screen display capabilities, bulb failure indicator(s), and an ambient light mode ("LEDinside") as results from this redesign effort. The user can toggie from the Surgical Light mode to the Ambient Light mode via use of a keypad switch mounted on the yoke of the lighthead. The "LEDinside" mode presents a ring of light mouthed from the bottom surface of the light, centered on the outer periphery of the sterile handle. Intensity can be adjusted to four levels: 30, 70, 110 and 150 Lux (@ 1m) and is sufficient to work on the patient in a dim or darkened operating room.

    The ALM X'Ten™ Product Family currently has four configurations available, as shown within Table 1.

    AI/ML Overview

    The provided text describes the ALM X'Ten™ Surgical Light System, but it does not contain a study section with acceptance criteria and a detailed analysis of how the device meets them. Instead, it lists the test data that supports conformance to various safety and performance standards.

    Therefore, I cannot fulfill all parts of your request directly from the provided input. However, I can extract the information that is present:

    1. A table of acceptance criteria and the reported device performance:

    The document states that the test data supports conformance to the following standards. These standards themselves contain the acceptance criteria, but the specific performance results from the testing are not reported in this document.

    Acceptance Criteria (Standards Conformed To)Reported Device Performance
    UL 60601-1 Standard for Medical Electrical Equipment, Part 1: General Requirements for SafetyConformance supported by test data
    UL60601-2-41 Medical electrical equipment Part 2-41: Particular requirements for the safety of surgical luminaires and luminaires for diagnosticsConformance supported by test data
    CSA C22.2 No. 601.1 Medical Electrical Equipment, Part 1: General Requirements for SafetyConformance supported by test data
    CSA C.22.2 No. 60601-2-41 Medical electrical equipment Part 2-41: Particular requirements for the safety of surgical luminaires and luminaires for diagnosticsConformance supported by test data
    IEC 60601-2-41 Medical electrical equipment Part 2-41: Particular requirements for the safety of surgical luminaires and luminaires for diagnosticsConformance supported by test data
    EN 60601-1-2 Medical electrical equipment Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and testsConformance supported by test data
    FCC Part 15Conformance supported by test data
    Appropriate FDA Software Guidance Documents (for Minor Level of Concern software)Tested according to these documents

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    This information is not provided in the document. The text only states that "test data supports conformance" but does not detail the testing methodology, sample sizes, or provenance of the data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    This information is not provided in the document. The testing described is against engineering and safety standards, not clinical ground truth established by experts.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not provided in the document.

    5. If a multi-reader, multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    No. An MRMC study was not done. This device is a surgical light system, and the filing indicates "No clinical data is required for this device classification submission." This type of study is typically associated with diagnostic AI systems.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This device is a surgical light system, not an algorithm, and its performance is assessed against technical safety and performance standards rather than in a standalone diagnostic context.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The "ground truth" for this device's performance is defined by its adherence to established international and national safety and performance standards for medical electrical equipment and surgical luminaires (e.g., UL 60601-1, IEC 60601-2-41). It is not based on clinical "ground truth" like pathology or outcomes data, as clinical data was not required.

    8. The sample size for the training set:

    Not applicable. This device is a physical surgical light system, not an AI model that requires a training set.

    9. How the ground truth for the training set was established:

    Not applicable. As above, no training set is relevant for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K040015

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2004-01-21

    (16 days)

    Product Code
    Regulation Number
    878.4580
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ALM S.A. PrismAlix® (PRX) Surgical Lights with Energix™ Power Supply are intended to be used to provide visible illumination of the surgical area or the patient. The Energix™ Power Supply is intended for use with surgical light systems.

    Device Description

    The PrismAlix® (PRX) Surgical Light System is an existing product line that will allow modification via the use of an updated Energix™ Power Supply as its means to control the surgical lighthead illumination levels. The updated Energix™ Power Supply contains software that enables additional features and capabilities not available on the earlier version of Energix™ Power Supplies. These include:

    • a) The power supply and regulators,
    • b) one or two touch-pad units that provide the user the ability to:
      • i) turn on/off one or two lightheads,
      • ii) adjust illumination intensity levels and
      • iii) additional Light Emitting Diodes (LEDs) are used to indicate:
        • (1) the illumination level,
        • (2) bulb failure sensing and
        • (3) power supply mode: Mains supply: green LED or the switching to a battery back-up system results in the LED indicator changing its color to red.
          An optional RS232 Communication Motherboard is also a new feature that allows shifting An optional ROZOE Ochinanicaa specified distance (50m, 164 ft.) away from the surgical Controls to a romote bite are provided specific user and maintenance type information/data, displayed on a Liquid Crystal Display (LCD) window located on the front information and the Energix™ power supply. The user also has an option to have data communicated to a personal computer (PC).
          The LCD can show information about preventive maintenance type items, including:
      1. programming of maintenance inspections
      1. storage of operating parameters
      1. hours of operation
      1. bulb life data
      1. self-diagnosis information
      1. direct reading of parameters voltage, current, temperature
      1. traceable management data serial number, software version number, production and service dates)
    AI/ML Overview

    The provided text describes a 510(k) summary for a modified surgical light, the ALM PrismAlix® (PRX) Surgical Light with an upgraded Energix™ Power Supply. This document focuses on demonstrating substantial equivalence to a predicate device rather than presenting a study proving performance against acceptance criteria for a new, innovative medical device from first principles.

    Therefore, the requested information elements related to clinical studies, ground truth establishment, expert adjudication, sample sizes, and AI performance are largely not applicable or not explicitly detailed in this type of regulatory submission.

    However, I can extract the relevant information regarding acceptance criteria (in this case, conformance to recognized standards) and the "study" (testing) that demonstrates this conformance.

    Here's the breakdown based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Standards Conformance)Reported Device Performance
    UL 2601-1 Standard for Medical Electrical Equipment, Part 1: General Requirements for SafetyTest data supports conformance
    CSA C22.2 No. 601.1 Medical Electrical Equipment, Part 1: General Requirements for SafetyTest data supports conformance
    IEC 60601-2-41 Medical electrical equipment Part 2-41: Particular requirements for the safety of surgical luminaires and luminaires for diagnosticsTest data supports conformance
    EN 60601-1-2 Medical electrical equipment Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and testsTest data supports conformance
    FDA Software Guidance Documents (for Minor Level of Concern software)Software was tested according to appropriate FDA guidance documents

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not specified in the document. This typically refers to the number of physical devices or components tested.
    • Data Provenance: The document states "Test Data" which implies internal testing conducted by the manufacturer or a contracted testing facility. The country of origin of the data is not specified, but the submission is for a US market regulated by the FDA. The testing conducted would be considered prospective in the sense that it was done specifically to demonstrate compliance for this submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • Not Applicable. The "ground truth" for this type of device (a surgical light system) is established by its adherence to widely recognized safety and performance standards, not by expert consensus on clinical findings. The testing involves objective measurements against predefined limits outlined in the standards.

    4. Adjudication Method (e.g., 2+1, 3+1, none) for the Test Set

    • Not Applicable. As no expert consensus or subjective assessment is involved, no adjudication method is used. Conformance is determined by objective measurements in line with the referenced standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    • No. This is a hardware device (surgical light) with some integrated software for control. It is not an AI-powered diagnostic or assistive tool for human readers, so an MRMC study is not relevant or performed.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • Not Applicable. This is not an algorithm-only device. The software present (in the Energix™ Power Supply) controls hardware components (light intensity, on/off, displays status information) and is integral to the device's function, not a standalone diagnostic algorithm.

    7. The Type of Ground Truth Used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" in this context is the predefined requirements and limits specified within the referenced international and national standards (UL, CSA, IEC, EN). The device's performance is measured against these technical specifications.

    8. The Sample Size for the Training Set

    • Not Applicable. There is no mention of a training set as this device does not utilize machine learning or AI models that require training. The software is deterministic control software.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. As there is no training set, this question is not relevant.